High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings

被引:118
作者
Boos, KS [1 ]
Grimm, CH [1 ]
机构
[1] Univ Hosp Grosshadern, Inst Clin Chem, D-81366 Munich, Germany
关键词
restricted access materials; solid-phase extraction; PROSPEKT; sample clean-up;
D O I
10.1016/S0165-9936(98)00102-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tailor-made precolumn packings for HPLC integrated extractive clean-up of (bio)fluids are characterized by possessing a defined diffusion barrier and a biocompatible outer particle surface (restricted access materials, RANI). Only analytes of low molecular mass have free access to the binding centers at the inner pore surface, and thus can be retained and extracted selectively. These adsorbents allow the easy, inexpensive installation and economic operation of fully automated coupled-column systems for repetitive on-line solid-phase extraction (SPE), and the subsequent analytical separation of untreated( bio)fluids. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 38 条
[1]  
ANDERSON DJ, 1993, ANAL CHEM, V65, pR434
[2]   Determination of fluvoxamine and paroxetine in human serum with highperformance liquid chromatography and ultraviolet detection [J].
Bagli, M ;
Rao, ML ;
Sobanski, T ;
Laux, G .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (02) :283-295
[3]   A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
CHROMATOGRAPHIA, 1995, 40 (7-8) :474-483
[4]   MICROPOROUS HYPERCROSSLINKED POLYSTYRENE STYROSORB AS A RESTRICTED ACCESS PACKING IN SAMPLE CLEANUP FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. EVALUATION OF RESTRICTED ACCESS PROPERTIES [J].
BETH, M ;
UNGER, KK ;
TSYURUPA, MP ;
DAVANKOV, VA .
CHROMATOGRAPHIA, 1993, 36 :351-355
[5]   DEVELOPMENT AND PERFORMANCE OF AN AUTOMATED HPLC-ANALYZER FOR CATECHOLAMINES [J].
BOOS, KS ;
WILMERS, B ;
SAUERBREY, R ;
SCHLIMME, E .
CHROMATOGRAPHIA, 1987, 24 :363-370
[6]   ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS [J].
BOOS, KS ;
RUDOLPHI, A ;
VIELHAUER, S ;
WALFORT, A ;
LUBDA, D ;
EISENBEISS, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :684-690
[7]  
Boos KS, 1997, LC GC-MAG SEP SCI, V15, P602
[8]   COLUMN-SWITCHING TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS IN BIOLOGICAL SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02) :177-190
[9]   SEMIPERMEABLE-SURFACE REVERSED-PHASE MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DESILETS, CP ;
ROUNDS, MA ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :25-39
[10]   SHIELDED HYDROPHOBIC PHASE - A NEW CONCEPT FOR DIRECT INJECTION-ANALYSIS OF BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GISCH, DJ ;
HUNTER, BT ;
FEIBUSH, B .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 :264-268