Hemoperfusion using dual pulsatile pump in paraquat poisoning

被引:19
作者
Suh, Gil J. [2 ]
Lee, Christopher C. [1 ]
Jo, Ik J. [3 ]
Shin, Sang D. [2 ]
Lee, Jung C. [4 ]
Min, Byung G. [4 ]
Singer, Adam J.
机构
[1] SUNY Stony Brook, Sch Med, Dept Emergency Med, Ctr Int Emergency Med,Med Ctr, Stony Brook, NY 11794 USA
[2] Seoul Natl Univ, Coll Med, Dept Emergency Med, Seoul, South Korea
[3] Sungkyunkwan Univ, Dept Emergency Med, Samsung Med Ctr, Seoul, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul, South Korea
关键词
D O I
10.1016/j.ajem.2007.09.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Hemoperfusion is an effective method for removing paraquat from the body. However, the need for special equipment and personnel to perform hemoperfusion limits its applicability in the emergency department. A portable, user-friendly extracorporeal life support system (Twin Pulse Life Support [T-PLS]) capable of producing dual pulsatile flow by an electromechanical blood pump has recently been developed. We compared the effects of hemoperfusion using traditional and dual-pulsatile pumps in a paraquat-intoxicated canine model. We hypothesized that T-PLS would be as effective as nompulsatile hemoperfusion in reducing plasma and tissue paraquat levels. Methods: Twelve adult male mongrel dogs were randomly assigned to hemoperfusion using a standard nonpulsatile pump (n = 6) or the T-PLS (n = 6). Paraquat intoxication was induced by intramuscular injection of paraquat (30 mg/kg). One hour after paraquat administration, hemoperfusion was performed for 4 hours at a flow rate of 125 mL/min. Periodic hemodynamic, chemical, and hematologic parameters as well as paraquat blood levels were obtained before and during the experiment. All animals were euthanized after completing 4 hours of hemoperfusion, and tissue levels of paraquat were determined. Results: During hemoperfusion, hemodynamic parameters including aortic blood pressure, heart rate, rectal temperature, and SaO(2) showed no significant difference between the T-PLS group and the nonpulsatile pump groups. Chemical and hematologic parameters such as serum electrolytes, platelet level, creatinine concentration, the ratio of blood urea nitrogen (BUN) to creatinine, alanine aminotransferase/aspartate aminotransferase (ALS/AST) levels, and plasma hemoglobin concentration as an indicator of hemolysis also showed no between-group differences. Plasma paraquat concentrations and lung and kidney tissue paraquat concentrations were also similar in both groups. Conclusions: In this experimental canine study, T-PLS was as effective as traditional nonpulsatile hemoperfusion in reducing plasma and tissues paraquat levels. There were also no differences in hemodynamic, chemical, and hematologic parameters between the groups. Hemoperfusion using T-PLS may play a role as an alternative method for treating patients with paraquat poisoning. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 22 条
[1]   PULSATILE REPERFUSION AFTER CARDIAC-ARREST IMPROVES NEUROLOGIC OUTCOME [J].
ANSTADT, MP ;
STONNINGTON, MJ ;
TEDDER, M ;
CRAIN, BJ ;
BROTHERS, MF ;
HILLEREN, DJ ;
RAHIJA, RJ ;
MENIUS, JA ;
LOWE, JE .
ANNALS OF SURGERY, 1991, 214 (04) :478-490
[2]   PULSATILE VERSUS NONPULSATILE REPERFUSION IMPROVES CEREBRAL BLOOD-FLOW AFTER CARDIAC-ARREST [J].
ANSTADT, MP ;
JONAS, RA ;
HANLEY, FL ;
TEDDER, M ;
HEGDE, SS ;
PEREZTAMAYO, RA ;
CRAIN, BJ ;
HA, VLK ;
ABDELALEEM, S ;
WHITE, WD ;
LOWE, JE .
ANNALS OF THORACIC SURGERY, 1993, 56 (03) :453-461
[3]  
BAEK KJ, 2002, J KOREAN SOC EMERG M, V13, P489
[4]   ELIMINATION OF PARAQUAT [J].
BISMUTH, C ;
SCHERRMANN, JM ;
GARNIER, R ;
BAUD, FJ ;
PONTAL, PG .
HUMAN TOXICOLOGY, 1987, 6 (01) :63-67
[5]  
CHIU IS, 1984, J CARDIOVASC SURG, V25, P530
[6]   A new automatic cardiac output control algorithm for moving actuator total artificial heart by motor current waveform analysis [J].
Choi, WW ;
Kim, HC ;
Min, BG .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (03) :189-196
[7]   IMPROVED ORGAN FUNCTION DURING CARDIAC BYPASS WITH A ROLLER PUMP MODIFIED TO DELIVER PULSATILE FLOW [J].
JACOBS, LA ;
KLOPP, EH ;
SEAMONE, W ;
TOPAZ, SR ;
GOTT, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (05) :703-+
[8]  
MARUYAMA H, 1986, CLIN CHEM, V32
[9]   A MOVING-ACTUATOR TYPE ELECTROMECHANICAL TOTAL ARTIFICIAL-HEART .2. CIRCULAR TYPE AND ANIMAL-EXPERIMENT [J].
MIN, BG ;
KIM, HC ;
CHOI, JW ;
RYU, GH ;
SEO, KP ;
RHO, JR ;
AHN, H ;
KIM, SW ;
DIEGEL, PD ;
OLSEN, DB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) :1195-1200
[10]   Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature [J].
Nakano, T ;
Tominaga, R ;
Nagano, I ;
Okabe, H ;
Yasui, H .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 278 (04) :H1098-H1104