Clinical Outcome of Total Knee Arthroplasty Performed Using Patient-Specific Cutting Guides

被引:5
作者
Calbiyik, Murat [1 ]
机构
[1] Hitit Univ, Fac Med, Dept Orthoped & Traumatol, Corum, Turkey
来源
MEDICAL SCIENCE MONITOR | 2017年 / 23卷
关键词
Arthroplasty; Replacement; Knee; Knee Dislocation; Osteotomy; INSTRUMENTS; ACCURACY; METAANALYSIS;
D O I
10.12659/MSM.908213
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Patient-specific instruments have recently gained attention for ensuring the accuracy of osteotomy and correct alignment in total knee arthroplasty (TKA). We aimed to report our experience with TKA performed by using CT-based 3D model of cutting guides in our clinic. Material/Methods: A total of 36 patients (mean age, 67.58 +/- 8.46 years; 24 females, 12 males) who underwent TKA with 3D patient-specific cutting guides in our clinic were included in the study. Differences between preoperatively planned bone resections and actual bone resections were calculated. Femoral and tibial component angles were measured on radiographs of the knee. The change in knee pain was evaluated by patients on a 10-point visual analog scale (VAS). Patients were followed up for 6 months postoperatively. Results: The actual bone resection was 0.5-1.5 mm higher than the planned resection for all sides, being statistically significant for posterior lateral and distal medial sides (1.1 +/- 1.3 mm and 1.5 +/- 0.9 mm, respectively; p<0.05). On postoperative radiographs, coronal tibial component angle was 88.8 degrees +/- 0.9 degrees and coronal femoral component angle was 95.2 degrees +/- 1.6 degrees, showing good postoperative alignment. The VAS pain score of patients significantly decreased from preoperative 3.9 +/- 0.8 to 1.1 +/- 0.9 at 6 months after the operation. One patient developed superficial tissue infection on postoperative follow-up, which was effectively treated. No other pathology was detected in the postoperative period. Conclusions: Patient-specific cutting guides can provide intraoperative guidance for better placement of the implant in TKA and increase the accuracy of osteotomy and postoperative alignment.
引用
收藏
页码:6168 / 6173
页数:6
相关论文
共 18 条
[1]   A comparison of short term radiological alignment outcomes of the patient specific and standard instrumentation for primary total knee arthroplasty: A systematic review and meta-analysis [J].
Alcelik, Ilhan ;
Blomfield, Mark ;
Ozturk, Cenk ;
Soni, Ashish ;
Charity, Richard ;
Acornley, Alex .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (03) :215-222
[2]   Thoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing [J].
Chen, Hongliang ;
Guo, Kaijing ;
Yang, Huilin ;
Wu, Dongying ;
Yuan, Feng .
MEDICAL SCIENCE MONITOR, 2016, 22 :1682-1686
[3]  
Colombelli Andrea, 2017, Acta Biomed, V88, P45, DOI 10.23750/abm.v88i2 -S.6511
[4]   Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial [J].
De Vloo, Raf ;
Pellikaan, Pim ;
Dhollander, Aad ;
Vander Sloten, Jos .
KNEE, 2017, 24 (06) :1469-1477
[5]  
Dell'Osso Giacomo, 2016, Surg Technol Int, V28, P243
[6]  
Gutierres MAP, 2016, REV BRAS ORTOP, V52, P242
[7]   Computer-assisted total knee arthroplasty using patient-specific templating [J].
Hafez, M. A. ;
Chelule, K. L. ;
Seedhom, B. B. ;
Sherman, K. P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) :184-192
[8]   A Novel Registration Method for Computer-Assisted Total Knee Arthroplasty Using a Patient-Specific Registration Guide [J].
Jang, Taeho ;
Lee, Kunwoo .
SURGICAL INNOVATION, 2014, 21 (01) :80-89
[9]  
Kievit AJ, 2017, KNEE SURG SPORTS TRA
[10]   The accuracy of bony resection from patient-specific guides during total knee arthroplasty [J].
Levy, Yadin D. ;
An, Vincent V. G. ;
Shean, Christopher J. W. ;
Groen, Floris R. ;
Walker, Peter M. ;
Bruce, Warwick J. M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) :1678-1685