Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers

被引:7
|
作者
Sader, John E. [1 ]
Friend, James R. [2 ]
机构
[1] Univ Melbourne, Sch Math & Stat, Melbourne, Vic 3010, Australia
[2] Univ Calif San Diego, Dept Mech & Aerosp Engn, La Jolla, CA 92093 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 05期
基金
澳大利亚研究理事会;
关键词
Atomic force microscopy - Uncertainty analysis - Nanocantilevers - Calibration - Springs (components);
D O I
10.1063/1.4921192
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever's spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Imaging using lateral bending modes of atomic force microscope cantilevers
    Caron, A
    Rabe, U
    Reinstädtler, M
    Turner, JA
    Arnold, W
    APPLIED PHYSICS LETTERS, 2004, 85 (26) : 6398 - 6400
  • [32] An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers
    Rui Li
    Hongfei Ye
    Weisheng Zhang
    Guojun Ma
    Yewang Su
    Scientific Reports, 5
  • [33] Note: Spring constant calibration of nanosurface-engineered atomic force microscopy cantilevers
    Ergincan, O.
    Palasantzas, G.
    Kooi, B. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [34] Tilt of atomic force microscope cantilevers: Effect on friction measurements
    Wang, Fei
    Zhao, Xuezeng
    PROGRESSES IN FRACTURE AND STRENGTH OF MATERIALS AND STRUCTURES, 1-4, 2007, 353-358 : 742 - 745
  • [35] Normal and torsional spring constants of atomic force microscope cantilevers
    Green, CP
    Lioe, H
    Cleveland, JP
    Proksch, R
    Mulvaney, P
    Sader, JE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (06): : 1988 - 1996
  • [36] Dynamic simulation of atomic force microscope cantilevers oscillating in liquid
    Martin, Michael James
    Fathy, Hosam K.
    Houston, Brian H.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (04)
  • [37] Actuation of atomic force microscope cantilevers by acoustic radiation pressure
    Onaran, AG
    Degertekin, FL
    Hadimioglu, B
    Sulchek, T
    Quate, CF
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 509 - 512
  • [38] Method to determine the spring constant of atomic force microscope cantilevers
    Gibson, CT
    Johnson, DJ
    Anderson, C
    Abell, C
    Rayment, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (02): : 565 - 567
  • [39] FRICTION EFFECTS IN THE DEFLECTION OF ATOMIC-FORCE MICROSCOPE CANTILEVERS
    WARMACK, RJ
    ZHENG, XY
    THUNDAT, T
    ALLISON, DP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (02): : 394 - 399
  • [40] Actuation of atomic force microscope cantilevers in fluids using acoustic radiation pressure
    Onaran, AG
    Degertekin, FL
    Hadimioglu, B
    Sulchek, T
    Quate, CF
    FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, : 356 - 359