Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

被引:13
作者
Alvarez-Arenal, Angel [1 ]
Gonzalez-Gonzalez, Ignacio [1 ]
deLlanos-Lanchares, Hector [1 ]
Martin-Fernandez, Elena [1 ]
Brizuela-Velasco, Aritza [2 ]
Ellacuria-Echebarria, Joseba [2 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, C Catedrat Serrano S-N, E-33006 Oviedo, Spain
[2] Univ Basque Country, Fac Med & Dent, Dept Oral Stomatol 1, Bilbao, Spain
关键词
Overdenture; Locator attachment; Stress; Occlusal load; Finite element analysis; QUALITY-OF-LIFE; IN-VITRO; RETAINED OVERDENTURES; SUPPORTED OVERDENTURES; 2-IMPLANT OVERDENTURES; EDENTULOUS PATIENTS; BREAKING ATTACHMENTS; CLINICAL-TRIAL; BONE; CONFIGURATIONS;
D O I
10.4047/jap.2017.9.5.371
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 55 条
[1]   THE IN VITRO EFFECT OF DIFFERENT IMPLANT ANGULATIONS AND CYCLIC DISLODGEMENT ON THE RETENTIVE PROPERTIES OF AN OVERDENTURE ATTACHMENT SYSTEM [J].
Al-Ghafli, Suhail Ali ;
Michalakis, Konstantinos X. ;
Hirayama, Hiroshi ;
Kang, Kiho .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (03) :140-147
[2]  
Andreiotelli M, 2010, INT J PROSTHODONT, V23, P195
[3]  
Anusavice KJ, 2013, PHILLIPS SCI DENT MA, P365
[4]   The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study [J].
Awad, Manal A. ;
Rashid, Faahim ;
Feine, Jocelyne S. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (01) :46-51
[5]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[6]   Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible - A computed tomography-based three-dimensional finite element analysis [J].
Barao, V. A. R. ;
Delben, J. A. ;
Lima, J. ;
Cabral, T. ;
Assuncao, W. G. .
JOURNAL OF BIOMECHANICS, 2013, 46 (07) :1312-1320
[7]   The Influence of the Attachment Type and Implant Number Supporting Mandibular Overdentures on Stress Distribution: An In Vitro Study, Part I [J].
Bilhan, Selda Arat ;
Bilhan, Hakan ;
Bozdag, Ergun ;
Sunbuloglu, Emin ;
Baykasoglu, Cengiz ;
Kutay, Omer .
IMPLANT DENTISTRY, 2013, 22 (01) :39-48
[8]  
Budtz-Jorgensen E., 1999, Prosthodontics For The Elderly: Diagnosis And Treatment - 1st Ed
[9]   Complications associated with the ball, bar and Locator attachments for implant-supported overdentures [J].
Cakarer, Sirmahan ;
Can, Taylan ;
Yaltirik, Mehmet ;
Keskin, Cengizhan .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (07) :C953-C959
[10]   Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws [J].
Carlsson, Gunnar E. .
JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (04) :245-252