Experiment study on collection and heat transfer characteristics of hot gas with coagulative particles flowing through a fixed granular bed with embedded heat exchange tubes
被引:6
作者:
Chen, Junlin
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Univ Chinese Acad Sci, Beijing 100049, Peoples R ChinaChinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Chen, Junlin
[1
,2
]
Li, Xunfeng
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Univ Chinese Acad Sci, Beijing 100049, Peoples R ChinaChinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Li, Xunfeng
[1
,2
]
Huai, Xiulan
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Univ Chinese Acad Sci, Beijing 100049, Peoples R ChinaChinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Huai, Xiulan
[1
,2
]
Xu, Min
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R ChinaChinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Xu, Min
[1
]
Zhou, Jingzhi
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R ChinaChinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
Zhou, Jingzhi
[1
]
机构:
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
The collection and heat transfer characteristics of hot gas with coagulative particles flowing through a novel fixed granular bed with embedded heat exchange tubes are experimentally investigated. The NaCl dust is used as coagulative particles, and the SiO2 dust is used as the solid particles to replace the NaCl for comparison. The experimental results show that the high collection efficiency can be achieved earlier for the coagulative particles than the solid particles, but the corresponding pressure drop is larger. In the initial stage of filtration, the overall heat transfer coefficient is higher for the coagulative particles than the solid particles, which increases with the rise of the inlet particles concentration. However, in the later stage of filtration, the overall heat transfer coefficient is lower for the coagulative particles than the solid particles, which increases while the inlet particles concentration decreases. The pressure drop caused by the coagulative particles increases with the decrease of the gas velocity and the rise of the inlet particles concentration. This novel structure can realize the high collection efficiency of > 98% and the high waste heat recovery efficiency of > 70% simultaneously.