False Negative Rate of Sentinel Lymph Node Biopsy on Intraoperative Frozen Section in Early Breast Cancer Patients: An Institutional Experience

被引:2
作者
Gupta, Sandhya [1 ]
Kadayaprath, Geeta [1 ]
Ambastha, Rooma [2 ]
Shrivastava, Shakti Saumnam [3 ]
机构
[1] MICC, Dept Surg Oncol, Breast Unit, New Delhi, India
[2] MICC, Dept Pathol, New Delhi, India
[3] MICC, New Delhi, India
关键词
False negative rate; Sentinel lymph node biopsy; Breast cancer; Intraoperative frozen section; AXILLARY DISSECTION; TRIAL;
D O I
10.1007/s13193-021-01458-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Sentinel lymph node biopsy is an established practice to avoid axillary clearance, in clinically negative axilla, in breast cancer patients. Sentinel nodes harvested by dual technique, if found negative on intraoperative frozen section, can prevent breast cancer patient from a potentially debilitating complete axillary clearance. Hence, analyzing the institutional accuracy of this technique and comparing it with international standards, becomes important in providing optimal treatment to these patients. A retrospective analysis of all patients who had undergone sentinel lymph node biopsy at our institute from December 2014 to December 2018 was carried out. At our institute, sentinel lymph nodes are identified using dual technique of methylene blue and radiocolloid dye. Intraoperative frozen section of these hot or blue or any enlarged nodes is performed. Patients with positive frozen section undergo complete axillary clearance. All frozen and unfrozen biopsy material is subjected to further paraffin sectioning and immunohistochemistry. False negative rate and factors associated with were analyzed. A total number of 424 patients had undergone intraoperative frozen section for the sentinel node in breast cancer at our institute during the study period. Among these, 307 patients had negative sentinel nodes and 117 had positive sentinel nodes of frozen section. Seventeen patients out of 307 had lymph node metastases in final paraffin report (false negative rate = 12.6%). Two of these were found to have macrometastasis, 13 had micrometastasis and 2 had isolated tumor cells on final immunohistochemistry report. Size of metastases to sentinel lymph node was found to be a statistically significant contributor to higher false negative rate. Sentinel lymph node biopsy using intraoperative frozen section, is a sensitive and specific technique of staging axilla in breast cancer patients. Detection of micrometastasis and isolated tumor cells present a technical challenge and are associated with higher false negative rates.
引用
收藏
页码:312 / 315
页数:4
相关论文
共 50 条
  • [21] Intraoperative palpation for clinically suspicious axillary sentinel lymph nodes reduces the false-negative rate of sentinel lymph node biopsy in breast cancer
    Carmon, M
    Olsha, O
    Rivkin, L
    Spira, RM
    Golomb, E
    BREAST JOURNAL, 2006, 12 (03) : 199 - 201
  • [22] Efficacy of frozen section in sentinel lymph node biopsy in early breast cancer - An Australian single-centre experience
    Novis, Elan
    Kim, Tae Jun
    Gauci, Chahaya
    Mui, Jasmine
    Gao, Yijun
    Garibotto, Natalia
    SURGERY IN PRACTICE AND SCIENCE, 2023, 15
  • [23] Lymph node wire localization post-chemotherapy: Towards improving the false negative sentinel lymph node biopsy rate in breast cancer patients
    Dashevsky, Brittany Z.
    Altman, Ashley
    Abe, Hiroyuki
    Jaskowiak, Nora
    Bao, Jean
    Schacht, David, V
    Sheth, Deepa
    Kulkarni, Kirti
    CLINICAL IMAGING, 2018, 48 : 69 - 73
  • [24] Intraoperative Frozen Section Analysis of Sentinel Lymph Nodes in Breast Cancer Patients
    Liu, Liang-Chih
    Lang, Julie E.
    Lu, Ying
    Roe, Denise
    Hwang, Shelley E.
    Ewing, Cheryl A.
    Esserman, Laura J.
    Morita, Eugene
    Treseler, Patrick
    Leong, Stanley P.
    CANCER, 2011, 117 (02) : 250 - 258
  • [25] Analysis of false negative rate in sentinel lymph node biopsy of breast cancer: a single centre retrospective study from China
    Wang, Xinzhao
    Liu, Zhaoyun
    Yu, Qian
    Xu, Nana
    Wang, Leilei
    Ma, Qinghua
    Yu, Zhiyong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16703 - 16709
  • [26] Beyond the False Negative Rate: Development of Quality Indicators for Sentinel Lymph Node Biopsy in Breast Cancer
    Quan, May Lynn
    Wells, Bryan J.
    McCready, David
    Wright, Frances C.
    Fraser, Novlette
    Gagliardi, Anna R.
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (02) : 579 - 591
  • [27] Factors affecting false-negative breast sentinel node biopsy in chinese patients
    Chok, Kenneth S. H.
    Suen, Dacita T. K.
    Lim, Fiona M. Y.
    Li, George K. H.
    Kwong, Ava
    ANZ JOURNAL OF SURGERY, 2007, 77 (10) : 866 - 869
  • [28] Intraoperative Frozen Section Analysis of Sentinel Lymph Node in Breast Cancer Patients Treated with Neoadjuvant Chemotherapy
    Kenzo Shimazu
    Yasuhiro Tamaki
    Tetsuya Taguchi
    Fumine Tsukamoto
    Tsutomu Kasugai
    Shinzaburo Noguchi
    Annals of Surgical Oncology, 2008, 15
  • [29] Sentinel lymph node biopsy in patients with multicentric/multifocal breast cancer: low false-negative rate and lack of axillary recurrence
    Hotwitt, Dana M.
    Gillanders, William E.
    Aft, Rebecca L.
    Eberlein, Timothy J.
    Margenthaler, Julie A.
    AMERICAN JOURNAL OF SURGERY, 2008, 196 (04) : 562 - 565
  • [30] Intraoperative frozen section analysis of sentinel lymph node in breast cancer patients treated with neoadjuvant chemotherapy
    Shimazu, Kenzo
    Tamaki, Yasuhiro
    Taguchi, Tetsuya
    Tsukamoto, Fumine
    Kasugai, Tsutomu
    Noguchi, Shinzaburo
    ANNALS OF SURGICAL ONCOLOGY, 2008, 15 (06) : 1717 - 1722