Extensor malalignment arising from femoral component malrotation in knee arthroplasty: Effect of rotating-bearing

被引:40
作者
Colwell, Clifford W., Jr. [1 ]
Chen, Peter C. [1 ]
D'Lima, Darryl [1 ]
机构
[1] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
Knee arthroplasty; Femoral component malrotation; Patellar tracking; Computer model; Knee biomechanics; PATELLAR TRACKING; CHAIN EXERCISE; REPLACEMENT; KINEMATICS; DESIGN; ALIGNMENT; JOINT; POSITION; CONTACT; SYSTEM;
D O I
10.1016/j.clinbiomech.2010.08.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Many patellofemoral complications such as anterior knee pain, subluxation, fracture, wear, and aseptic loosening after total knee arthroplasty are attributed to malrotation of the femoral component. Rotating-platform mobile bearings can reduce malrotation between the tibial and femoral components and may also improve patellofemoral maltracking. Methods: A computer model (LifeMOD/KneeSIM) of a weight-bearing deep knee bend was validated using cadaver knees tested in an Oxford-type knee rig. Changes in knee kinematics and patellofemoral forces were measured after femoral component malrotation of +/-3 degrees. The effect of a rotating-bearing on these kinematics and forces was determined. Findings: In a fixed-bearing arthroplasty femoral component internal malrotation increased tibiofemoral internal rotation by 3.4 degrees, and external malrotation increased tibiofemoral external rotation by 4 degrees. Femoral component malrotation affected patellofemoral lateral shift by up to 2.5 mm, and patellofemoral lateral shear by up to 19 N. When the malrotated femoral component was tested against a rotating-bearing the change in tibiofemoral rotation and patellofemoral lateral shift was less than 1 degrees and 1 mm respectively. The rotating-bearing reduced peak lateral shear by 7 N and peak medial shear by 17 N. Increasing the conformity of the rotating-bearing reduced changes in tibiofemoral rotation due to femoral malrotation and increased the net rotation of the bearing (by approximately 5 degrees) during flexion. Interpretation: Our results are consistent with one randomized clinical outcome study and emphasize the value of computational modeling for preclinical design evaluation. It is important to continue to improve existing methodologies for accurate femoral component alignment especially in rotation. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 31 条
[1]   Patellofemoral design influences function following total knee arthroplasty [J].
Andriacchi, TP ;
Yoder, D ;
Conley, A ;
Rosenberg, A ;
Sum, J ;
Galante, JO .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :243-249
[2]   THE INFLUENCE OF TOTAL KNEE-REPLACEMENT DESIGN ON WALKING AND STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
FERMIER, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1328-1335
[3]  
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
[4]   Patellar position after total knee arthroplasty - Influence of femoral component malposition [J].
Armstrong, AD ;
Brien, HJC ;
Dunning, CE ;
King, GJW ;
Johnson, JA ;
Chess, DG .
JOURNAL OF ARTHROPLASTY, 2003, 18 (04) :458-465
[5]   Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[6]   ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[7]   LONG-TERM COMPLICATIONS AFTER TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT RESURFACING OF THE PATELLA [J].
BOYD, AD ;
EWALD, FC ;
THOMAS, WH ;
POSS, R ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :674-681
[8]  
BRICK GW, 1988, CLIN ORTHOP RELAT R, P163
[9]   Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm [J].
Browne, C ;
Hermida, JC ;
Bergula, A ;
Colwell, CW ;
D'Lima, DD .
KNEE, 2005, 12 (02) :81-88
[10]  
BUECHEL FF, 1989, ORTHOP CLIN N AM, V20, P147