In-vivo, real-time cross-sectional images of retina using a GPU enhanced master slave optical coherence tomography system

被引:0
|
作者
Bradu, Adrian [1 ]
Kapinchev, Konstantin [2 ]
Barnes, Frederick [2 ]
Podoleanu, Adrian [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
[2] Univ Kent, Sch Comp, Canterbury CT2 7NF, Kent, England
来源
OPHTHALMIC TECHNOLOGIES XXVI | 2016年 / 9693卷
关键词
optical coherence tomography; master slave; CUDA; graphics cards; imaging retina;
D O I
10.1117/12.2211072
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
In our previous reports we demonstrated a novel Fourier domain optical coherence tomography method, Master Slave optical coherence tomography (MS-OCT), that does not require resampling of data and can deliver en-face images from several depths simultaneously. While ideally suited for delivering information from a selected depth, the MS-OCT has been so far inferior to the conventional FFT based OCT in terms of time of producing cross section images. Here, we demonstrate that by taking advantage of the parallel processing capabilities offered by the MS-OCT method, cross-sectional OCT images of the human retina can be produced in real-time by assembling several T-scans from different depths. We analyze the conditions that ensure a real-time B-scan imaging operation, and demonstrate in-vivo real-time images from human fovea and the optic nerve, of comparable resolution and sensitivity to those produced using the traditional Fourier domain based method.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] In vivo imaging of dynamic biological specimen by real-time single-shot full-field optical coherence tomography
    Hrebesh, Molly Subhash
    Dabu, Razvan
    Sato, Manabu
    OPTICS COMMUNICATIONS, 2009, 282 (04) : 674 - 683
  • [42] Simultaneous real-time quantification of blood flow and vascular growth in the chick embryo using optical coherence tomography
    Kowalski, William J.
    Teslovich, Nikola C.
    Chen, Chia-Yuan
    Keller, Bradley B.
    Pekkan, Kerem
    OPTICAL METHODS IN DEVELOPMENTAL BIOLOGY II, 2014, 8953
  • [43] Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system
    Paul Hahn
    Justin Migacz
    Rachelle O’Connell
    Joseph A. Izatt
    Cynthia A. Toth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 213 - 220
  • [44] Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system
    Hahn, Paul
    Migacz, Justin
    O'Connell, Rachelle
    Izatt, Joseph A.
    Toth, Cynthia A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 213 - 220
  • [45] Near real-time classification of optical coherence tomography data using principal components fed linear discriminant analysis
    Bazant-Hegemark, Florian
    Stone, Nicholas
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (03)
  • [46] Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography
    Kitahara, Hideki
    Waseda, Katsuhisa
    Yamada, Ryotaro
    Otagiri, Kyuhachi
    Tanaka, Shigemitsu
    Kobayashi, Yuhei
    Okada, Kozo
    Kume, Teruyoshi
    Nakagawa, Kaori
    Teramoto, Tomohiko
    Ikeno, Fumiaki
    Yock, Paul G.
    Fitzgerald, Peter J.
    Honda, Yasuhiro
    EUROINTERVENTION, 2016, 12 (02) : E190 - E198
  • [47] Measurement of Foveal Retinal Thickness in Myopic Patients Using Different Display Modes on Optical Coherence Tomography: A Retrospective, Cross-Sectional Study
    Lawali, Dan Jouma A. Maman
    Wu, Guanrong
    Guo, Yunxiang
    Lin, Zhangjie
    Wu, Qiaowei
    Amza, Abdou
    Du, Zijing
    Ren, Yun
    Fang, Ying
    Dong, Xinran
    Hu, Yunyan
    Niu, Yongyi
    Zhang, Hongyang
    Yu, Honghua
    Yang, Xiaohong
    Hu, Yijun
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (01) : 167 - 178
  • [48] Measurement of Foveal Retinal Thickness in Myopic Patients Using Different Display Modes on Optical Coherence Tomography: A Retrospective, Cross-Sectional Study
    Dan Jouma A. Maman Lawali
    Guanrong Wu
    Yunxiang Guo
    Zhangjie Lin
    Qiaowei Wu
    Abdou Amza
    Zijing Du
    Yun Ren
    Ying Fang
    Xinran Dong
    Yunyan Hu
    Yongyi Niu
    Hongyang Zhang
    Honghua Yu
    Xiaohong Yang
    Yijun Hu
    Ophthalmology and Therapy, 2023, 12 : 167 - 178
  • [49] Intraoperative optical coherence tomography using an optimized reflective optical relay, real-time heads-up display, and semitransparent surgical instrumentation
    Tao, Yuankai K.
    El-Haddad, Mohamed T.
    Srivastava, Sunil K.
    Feiler, Daniel
    Noonan, Amanda I.
    Rollins, Andrew M.
    Ehlers, Justis P.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIX, 2015, 9312
  • [50] Non-invasive characterization of anterior segment structures using real-time optical coherence tomography at 1310nm
    Radhakrishnan, S
    Reeves, D
    Lass, JH
    Bardenstein, DS
    Rollins, AM
    Westphal, V
    Roth, JE
    Izatt, JA
    PHOTON MIGRATION, OPTICAL COHERENCE TOMOGRAPHY, AND MICROSCOPY, 2001, 4431 : 43 - 45