In-vivo, real-time cross-sectional images of retina using a GPU enhanced master slave optical coherence tomography system

被引:0
|
作者
Bradu, Adrian [1 ]
Kapinchev, Konstantin [2 ]
Barnes, Frederick [2 ]
Podoleanu, Adrian [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
[2] Univ Kent, Sch Comp, Canterbury CT2 7NF, Kent, England
来源
OPHTHALMIC TECHNOLOGIES XXVI | 2016年 / 9693卷
关键词
optical coherence tomography; master slave; CUDA; graphics cards; imaging retina;
D O I
10.1117/12.2211072
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
In our previous reports we demonstrated a novel Fourier domain optical coherence tomography method, Master Slave optical coherence tomography (MS-OCT), that does not require resampling of data and can deliver en-face images from several depths simultaneously. While ideally suited for delivering information from a selected depth, the MS-OCT has been so far inferior to the conventional FFT based OCT in terms of time of producing cross section images. Here, we demonstrate that by taking advantage of the parallel processing capabilities offered by the MS-OCT method, cross-sectional OCT images of the human retina can be produced in real-time by assembling several T-scans from different depths. We analyze the conditions that ensure a real-time B-scan imaging operation, and demonstrate in-vivo real-time images from human fovea and the optic nerve, of comparable resolution and sensitivity to those produced using the traditional Fourier domain based method.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Real-time monitoring of hemodynamic changes in tumor vessels during photoimmunotherapy using optical coherence tomography
    Liang, Chia-Pin
    Nakajima, Takahito
    Watanabe, Rira
    Sato, Kazuhide
    Choyke, Peter L.
    Chen, Yu
    Kobayashi, Hisataka
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (09)
  • [32] Real-time retinal imaging with a parallel optical coherence tomography using a CMOS smart array detector
    Kim, Jeehyun
    Sohn, Bong-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (05) : 1787 - 1791
  • [33] Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning
    Lyu, J.
    Ren, L.
    Liu, Q-Y
    Wang, Y.
    Zhou, Z-Q
    Chen, Y-Y
    Jia, H-B
    Tang, Y-G
    Li, M.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (20) : 7349 - 7358
  • [34] Using Enhanced Depth Imaging Optical Coherence Tomography-Derived Parameters to Discriminate between Eyes with and without Glaucoma: A Cross-Sectional Comparative Study
    Lopes, Flavio Siqueira Santos
    Matsubara, Igor
    Almeida, Izabela
    Gracitelli, Carolina Pelegrini Barbosa
    Dorairaj, Syril K.
    Vessani, Roberto Murad
    Paranhos Jr., Augusto
    Prata, Tiago Santos
    OPHTHALMIC RESEARCH, 2021, 64 (01) : 108 - 115
  • [35] Increased retinal thickness in sarcoidosis patients with ocular system involvement visualized with optical coherence tomography: a cross-sectional study
    Byg, Keld-Erik
    Ellingsen, Torkell
    Wied, Jimmi
    Peiris, Michella
    Lowater, Simon Joel
    Sejbaek, Tobias
    Grauslund, Jakob
    RHEUMATOLOGY INTERNATIONAL, 2025, 45 (03)
  • [36] Non-Destructive Cross-Sectional Imaging of Tomato Using Ultra-High Resolution Optical Coherence Tomography
    Yamanaka, Masahito
    Kawagoe, Hiroyuki
    Nishizawa, Norihiko
    2015 54TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2015, : 95 - 96
  • [37] Visualization of Real-Time Intraoperative Maneuvers with a Microscope-Mounted Spectral Domain Optical Coherence Tomography System
    Ehlers, Justis P.
    Tao, Yuankai K.
    Farsiu, Sina
    Maldonado, Ramiro
    Izatt, Joseph A.
    Toth, Cynthia A.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (01): : 232 - 236
  • [38] Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor
    Su, Jianping
    Zhang, Jun
    Yu, Lingfeng
    Colt, Henri G.
    Brenner, Matthew
    Chen, Zhongping
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (03)
  • [39] Calibration of histological retina specimens after fixation in Margo’s solution and paraffin embedding to in-vivo dimensions, using photography and optical coherence tomography
    Stefan Koinzer
    Sandra Bajorat
    Carola Hesse
    Amke Caliebe
    Marco Bever
    Ralf Brinkmann
    Christoph Roecken
    Johann Roider
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 145 - 153
  • [40] Calibration of histological retina specimens after fixation in Margo's solution and paraffin embedding to in-vivo dimensions, using photography and optical coherence tomography
    Koinzer, Stefan
    Bajorat, Sandra
    Hesse, Carola
    Caliebe, Amke
    Bever, Marco
    Brinkmann, Ralf
    Roecken, Christoph
    Roider, Johann
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (01) : 145 - 153