Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry

被引:23
作者
Liu, Chao [1 ]
Zeng, Jiafa [1 ,4 ,5 ]
Sinues, Pablo [4 ,5 ]
Fang, Mingliang [6 ]
Zhou, Zhen [1 ,2 ,3 ]
Li, Xue [1 ,2 ,3 ]
机构
[1] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Guangzhou 510632, Peoples R China
[2] Guangzhou Hexin Instrument Co LTD, Guangzhou 510530, Peoples R China
[3] Guangdong Hongkong Macau Joint Lab Collaborat Inn, Guangzhou 510632, Peoples R China
[4] Basel Univ, Dept Biomed Engn, CH-4123 Allschwil, Switzerland
[5] Univ Basel, Childrens Hosp UKBB, CH-4056 Basel, Switzerland
[6] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
Volatile organic compounds; Secondary electrospray ionization; High resolution mass spectrometry; Quantitative analysis; REAL-TIME ANALYSIS; BREATH ANALYSIS; TRACE GASES; OPEN-AIR; IDENTIFICATION; DEGRADATION; EXPOSURE; DISEASE; TEDLAR; VAPOR;
D O I
10.1016/j.aca.2021.338876
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Secondary electrospray ionization coupled with high resolution mass spectrometry (SESI-HRMS) is a direct mass spectrometry technique, which can identify trace volatile organic compounds (VOCs) in real time without sample pretreatment and chromatographic separation. SESI-HRMS has been successfully applied in multiple applications, including breath analysis, animals and plants VOCs emissions, analysis of headspace of cell cultures and indoor and outdoor air. The range of areas where the technique can potentially have a substantial impact is very broad. However, one critical aspect that requires further development to consolidate the technique is absolute quantification. Therefore, in this study we aim to develop a quantitative method for eight representative VOCs, including ketones (acetone, 2-butanone and 2-pentanone), alkenes (isoprene and alpha-terpinene) and aromatics (toluene, styrene and mesitylene). The mass spectrometric platform includes a commercial SESI source hyphenated with a Q-Exactive hybrid quadrupole Orbitrap high resolution mass spectrometer. Within the concentration range of 0-100 ppbv studied, the optimal coefficient of determination for linear regression (R-2 = 0.993-0.999) between signal intensity and concentration is obtained in the range of 0-10 ppbv for all eight VOCs. The detection limits range between 3 (2-Pentanone) and 15 (Acetone) pptv. The intraday (n = 10) and inter day (n = 30) coefficients of variation (CV) are <= 6% and <= 10%, respectively. Finally the method is applied for the fast evaluation (<5 min) of different materials widely used for the collection, storage or pretreatment of gas sample. Better recovery of trace levels of eight VOCs is observed for PTFE gas sampling bag as compared to Nalophan and Tedlar bags; when Nafion tube is used to pretreat the gas sample, recovery of <= 50% are obtained for 2-pentanone, alpha-terpinene and all three aromatics. (C) 2021 Published by Elsevier B.V.
引用
收藏
页数:6
相关论文
共 49 条
[1]   OUR PRESENT UNDERSTANDING OF THE GAS-PHASE ATMOSPHERIC DEGRADATION OF VOCs [J].
Atkinson, R. .
SIMULATION AND ASSESSMENT OF CHEMICAL PROCESSES IN A MULTIPHASE ENVIRONMENT, 2008, :1-19
[2]   Real-time mass spectrometric identification of metabolites characteristic of chronic obstructive pulmonary disease in exhaled breath [J].
Bregy, Lukas ;
Nussbaumer-Ochsner, Yvonne ;
Sinues, Pablo Martinez-Lozano ;
Garcia-Gomez, Diego ;
Suter, Yannick ;
Gaisl, Thomas ;
Stebler, Nina ;
Gaugg, Martin Thomas ;
Kohler, Malcolm ;
Zenobi, Renato .
CLINICAL MASS SPECTROMETRY, 2018, 7 :29-35
[3]   Influence of Exposure Route and Oral Dosage Regimen on 1,1-Dichloroethylene Toxicokinetics and Target Organ Toxicity [J].
Bruckner, J. V. ;
White, C. A. ;
Muralidhara, S. ;
Hines, C. ;
Dallas, C. E. .
JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2010, 333 (02) :519-527
[4]   BREATH AND BLOOD-LEVELS OF BENZENE, TOLUENE, CUMENE AND STYRENE IN NON-OCCUPATIONAL EXPOSURE [J].
BRUGNONE, F ;
PERBELLINI, L ;
FACCINI, GB ;
PASINI, F ;
MARANELLI, G ;
ROMEO, L ;
GOBBI, M ;
ZEDDE, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1989, 61 (05) :303-311
[5]   Investigation of lung cancer biomarkers by hyphenated separation techniques and chemometrics [J].
Buszewski, Boguslaw ;
Ulanowska, Agnieszka ;
Kowalkowski, Tomasz ;
Cieslinski, Krzysztof .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (03) :573-581
[6]  
Caprioli R.M., 1997, Selected topics in mass spectrometry in the biomolecular sciences
[7]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[8]   Noninvasive detection of lung cancer using exhaled breath [J].
Fu, Xiao-An ;
Li, Mingxiao ;
Knipp, Ralph J. ;
Nantz, Michael H. ;
Bousamra, Michael .
CANCER MEDICINE, 2014, 3 (01) :174-181
[9]   Real-time, in vivo monitoring and pharmacokinetics of valproic acid via a novel biomarker in exhaled breath [J].
Gamez, Gerardo ;
Zhu, Liang ;
Disko, Andreas ;
Chen, Huanwen ;
Azov, Vladimir ;
Chingin, Konstantin ;
Kraemer, Guenter ;
Zenobi, Renato .
CHEMICAL COMMUNICATIONS, 2011, 47 (17) :4884-4886
[10]   Applications of DART-MS for food quality and safety assurance in food supply chain [J].
Guo, Tianyang ;
Yong, Wei ;
Jin, Yong ;
Zhang, Liya ;
Liu, Jiahui ;
Wang, Sai ;
Chen, Qilong ;
Dong, Yiyang ;
Su, Haijia ;
Tan, Tianwei .
MASS SPECTROMETRY REVIEWS, 2017, 36 (02) :161-187