Models of the Long-term Mechanical Strength of Long Rod Composite Insulators

被引:17
作者
Wankowicz, Jacek [1 ]
Bielecki, Jerzy [1 ]
机构
[1] Inst Energetyki, Warsaw, Poland
关键词
Composite insulator; fatigue strength; insulators testing; mechanical factors; dynamic response; NONCERAMIC INSULATORS; FAILURE ANALYSES;
D O I
10.1109/TDEI.2010.5448089
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Different mathematical models of long-term fatigue strength of long-rod insulators were evaluated by studying the effects of superimposed cyclic and constant loads. It has been shown that the strength of composite insulators can well be represented by the power type behavior of the fatigue characteristics and that the time to fatigue failure of a composite insulator strongly depends of the cyclic load amplitude and the maximum level of the total load. It has also been shown that the diameter of the core of composite insulator with crimp-mounted end fittings is the major factor determining the insulator's fatigue and static strength.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 16 条
[1]  
[Anonymous], 2008, IEC 61109
[2]  
ARGASINSKA H, 2001, DYNAMIC OCCURR UNPUB
[3]   RESPONSE OF COMPOSITE INSULATORS TO DYNAMIC MECHANICAL LOADS [J].
DETOURREIL, CH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (01) :379-383
[4]  
*EN, 2001, 5034112001 EN
[5]  
GUERY D, 2008, B2214 CIGRE
[6]  
*IEC, 1995, 611091992 IEC, pA1
[7]  
*IEC, 1997, 6146611997 IEC
[8]  
JAKUBOWICZ A, 1984, MAT STRENGTH, P586
[9]   Failure analyses of nonceramic insulators: Part II - The brittle fracture model and failure prevention [J].
Kumosa, M ;
Kumosa, L ;
Armentrout, D .
IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (04) :28-41
[10]   Failure analyses of nonceramic insulators part 1: Brittle fracture characteristics [J].
Kumosa, M ;
Kumosa, L ;
Armentrout, D .
IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (03) :14-27