Intracranial Nonthermal Irreversible Electroporation: In Vivo Analysis

被引:120
作者
Garcia, Paulo A. [1 ]
Rossmeisl, John H., Jr. [2 ]
Neal, Robert E., II [1 ]
Ellis, Thomas L. [3 ]
Olson, John D. [4 ]
Henao-Guerrero, Natalia [2 ]
Robertson, John [2 ]
Davalos, Rafael V. [1 ,5 ]
机构
[1] Virginia Tech Wake Forest Univ, Virginia Tech, Bioelectromech Syst BEMS Lab, SBES, Blacksburg, VA 24061 USA
[2] Virginia Maryland Reg Coll Vet Med, Blacksburg, VA 24061 USA
[3] Wake Forest Univ, Bowman Gray Sch Med, Dept Neurosurg, Winston Salem, NC 27157 USA
[4] Wake Forest Univ, Bowman Gray Sch Med, Ctr Biomol Imaging, Winston Salem, NC 27157 USA
[5] Virginia Polytech Inst & State Univ, Bioelectromech Syst BEMS Lab, Dept Engn Sci & Mech ESM, Blacksburg, VA 24061 USA
基金
美国国家科学基金会;
关键词
Brain cancer therapy; Minimally invasive surgery; Nonthermal ablation; Tumor ablation; Electropermeabilization; Bioheat transfer; Finite element analysis; Electric field correlation; Electrical conductivity; ELECTRICAL-IMPEDANCE TOMOGRAPHY; TISSUE ELECTROPORATION; TUMOR ABLATION; GENE-THERAPY; MODEL; ELECTROPERMEABILIZATION; ELECTROCHEMOTHERAPY; ELECTROTRANSFER; CONDUCTIVITY; DOGS;
D O I
10.1007/s00232-010-9284-z
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nonthermal irreversible electroporation (NTIRE) is a new minimally invasive technique to treat cancer. It is unique because of its nonthermal mechanism of tumor ablation. Intracranial NTIRE procedures involve placing electrodes into the targeted area of the brain and delivering a series of short but intense electric pulses. The electric pulses induce irreversible structural changes in cell membranes, leading to cell death. We correlated NTIRE lesion volumes in normal brain tissue with electric field distributions from comprehensive numerical models. The electrical conductivity of brain tissue was extrapolated from the measured in vivo data and the numerical models. Using this, we present results on the electric field threshold necessary to induce NTIRE lesions (495-510 V/cm) in canine brain tissue using 90 50-mu s pulses at 4 Hz. Furthermore, this preliminary study provides some of the necessary numerical tools for using NTIRE as a brain cancer treatment. We also computed the electrical conductivity of brain tissue from the in vivo data (0.12-0.30 S/m) and provide guidelines for treatment planning and execution. Knowledge of the dynamic electrical conductivity of the tissue and electric field that correlates to lesion volume is crucial to ensure predictable complete NTIRE treatment while minimizing damage to surrounding healthy tissue.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 43 条
[1]   A study of the immunological response to tumor ablation with irreversible Electroporation [J].
Al-Sakere, B. ;
Bernat, C. ;
Andr, F. ;
Connault, E. ;
Opolon, P. ;
Davalos, R. V. ;
Mir, L. M. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (04) :301-305
[2]   Tumor Ablation with Irreversible Electroporation [J].
Al-Sakere, Bassim ;
Andre, Franck ;
Bernat, Claire ;
Connault, Elisabeth ;
Opolon, Paule ;
Davalos, Rafael V. ;
Rubinsky, Boris ;
Mir, Lluis M. .
PLOS ONE, 2007, 2 (11)
[3]   Irreversible Electroporation: A New Challenge in "Out of Operating Theater" Anesthesia [J].
Ball, Christine ;
Thomson, Kenneth R. ;
Kavnoudias, Helen .
ANESTHESIA AND ANALGESIA, 2010, 110 (05) :1305-1309
[4]   Numerical modeling of in vivo plate electroporation thermal dose assessment [J].
Becker, SM ;
Kuznetsov, AV .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01) :76-84
[5]   Neuroimaging in Neuro-Oncology [J].
Cha, Soonmee .
NEUROTHERAPEUTICS, 2009, 6 (03) :465-477
[6]   Utility of magnetic resonance imaging for distinguishing neoplastic from non-neoplastic brain lesions in dogs and cats [J].
Cherubini, GB ;
Mantis, P ;
Martinez, TA ;
Lamb, CR ;
Cappello, R .
VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (05) :384-387
[7]   Electric and thermal field effects in tissue around radiofrequency electrodes [J].
Cosman, ER ;
Cosman, ER .
PAIN MEDICINE, 2005, 6 (06) :405-424
[8]   Real time electroporation control for accurate and safe in vivo non-viral gene therapy [J].
Cukjati, David ;
Batiuskaite, Danute ;
Andre, Franck ;
Miklavcic, Damijan ;
Mir, Lluis M. .
BIOELECTROCHEMISTRY, 2007, 70 (02) :501-507
[9]   Electrical impedance tomography of cell viability in tissue with application to cryosurgery [J].
Davalos, R ;
Rubinsky, B .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (02) :305-309
[10]   Temperature considerations during irreversible electroporation [J].
Davalos, Rafael V. ;
Rubinsky, Boris .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (23-24) :5617-5622