Thermal analysis of a pool fire test in a steel container

被引:1
|
作者
Cheng, Xudong [1 ,2 ]
Bystrom, Alexandra [1 ]
Wickstrom, Ulf [1 ,3 ]
Veljkovic, Milan [1 ]
机构
[1] Lulea Univ Technol, Div Struct & Construct Engn, S-97187 Lulea, Sweden
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Peoples R China
[3] SP Tech Res Inst Sweden, Boras, Sweden
关键词
Thermal analysis; adiabatic surface temperature; pool fire; FDS; COMBUSTION CHARACTERISTICS; VENTILATION; TUNNEL;
D O I
10.1177/0734904111432834
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A pool fire test was conducted in an uninsulated steel container under low ambient temperature condition, at -20 degrees C. The heat balance of the enclosure fire was analyzed. The size of the container was 12 mx 2.4 m and 2.4 m high, and it was made of 3-mm-thick steel. During the fire test, the fuel mass loss rate was recorded and the temperatures at different positions were measured with high-temperature thermocouples and plate thermometers. The fire scenario was simulated by using fire dynamics simulator software, and the simulated and measured results were compared. The coarse high-temperature thermocouple responded slower, and therefore, temperature measured by the high-temperature thermocouple was corrected to eliminate the effect of the thermal inertia. Furthermore, a simple two-zone model was proposed for estimating gas temperature in the enclosure of the highly conductive steel walls assuming a constant combustion rate. The convective and radiative heat transfer resistances at the inside and outside surfaces of the enclosure were analyzed.
引用
收藏
页码:170 / 184
页数:15
相关论文
共 50 条
  • [1] Theoretical analysis of the liquid thermal structure in a pool fire
    Beji, Tarek
    JOURNAL OF FIRE SCIENCES, 2021, 39 (01) : 36 - 52
  • [2] Finite Element Thermal Analysis of the Packing Container in Fire Environment
    Huang, Peng
    Hao, Zhiming
    Li, Weifen
    Hu, Shaoquan
    ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, PTS 1 AND 2, 2014, 444-445 : 1539 - 1544
  • [3] Pool fire accident in an aboveground LFO tank storage: thermal analysis
    Rebec, A.
    Plesec, P.
    Kolsek, J.
    FIRE SAFETY JOURNAL, 2014, 67 : 135 - 150
  • [4] VALIDATION OF CONTAINER ANALYSIS FIRE ENVIRONMENT (CAFE) CODE FOR MEMORIAL TUNNEL FIRE VENTILATION TEST PROGRAM
    Chalasani, N. R.
    Greiner, Miles
    Suo-Anttila, Ahti
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 7, 2010, : 561 - 571
  • [5] Thermal response of steel structures to fire: test versus field conditions
    LaMalva, Kevin J.
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2011, 21 (04) : 285 - 299
  • [6] Simulating the fire-thermal-structural behavior in a localized fire test on a bare steel beam
    Zhang, Chao
    Yu, Hong-Xia
    Choe, Lisa
    Gross, John
    Li, Guo-Hua
    ENGINEERING STRUCTURES, 2018, 163 : 61 - 70
  • [7] ESTIMATION OF THERMAL BALANCE IN HEPTANE POOL FIRE
    KOSEKI, H
    HAYASAKA, H
    JOURNAL OF FIRE SCIENCES, 1989, 7 (04) : 237 - 250
  • [8] Analysis of thermal radiation models for large open pool fire on ship deck
    Ding Li-bin
    Pu Jin-yun
    Ren Kai
    MECHANICAL ENGINEERING, MATERIALS SCIENCE AND CIVIL ENGINEERING II, 2014, 470 : 259 - 262
  • [9] Thermal analysis of steel decking concrete slabs in case of fire
    Bolina, Fabricio
    Tutikian, Bernardo
    Rodrigues, Joao Paulo C.
    FIRE SAFETY JOURNAL, 2021, 121
  • [10] Steel-steel composite metal foam in simulated pool fire testing
    Rabiei, A.
    Karimpour, K.
    Basu, D.
    Janssens, M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 153