MR-based respiratory and cardiac motion correction for PET imaging

被引:60
|
作者
Kuestner, Thomas [1 ,2 ]
Schwartz, Martin [1 ,3 ]
Martirosian, Petros [3 ]
Gatidis, Sergios [2 ]
Seith, Ferdinand [2 ]
Gilliam, Christopher [4 ]
Blu, Thierry [4 ]
Fayad, Hadi [5 ]
Visvikis, Dimitris [5 ]
Schick, F. [3 ]
Yang, B. [1 ]
Schmidt, H. [2 ]
Schwenzer, N. F. [2 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Stuttgart, Germany
[2] Univ Tubingen, Dept Radiol, Tubingen, Germany
[3] Univ Tubingen, Sect Expt Radiol, Tubingen, Germany
[4] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[5] Univ Bretagne, INSERM, U1101, LaTIM, Brest, France
关键词
PET/MR motion correction; Respiratory and cardiac motion correction; Image registration; Gadgetron; RECONSTRUCTION; TIME; NAVIGATOR; PET/MRI; HEART; LIVER; REGISTRATION; COMBINATION; MOVEMENTS; SEQUENCE;
D O I
10.1016/j.media.2017.08.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. Methods: A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). Results: A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. Conclusion: The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 144
页数:16
相关论文
共 50 条
  • [41] Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction
    Ulrike Attenberger
    Ciprian Catana
    Hersh Chandarana
    Onofrio A Catalano
    Kent Friedman
    Stefan A Schonberg
    James Thrall
    Marco Salvatore
    Bruce R. Rosen
    Alexander R. Guimaraes
    Abdominal Imaging, 2015, 40 : 1374 - 1386
  • [42] MR-Based Attenuation Correction Methods for Improved PET Quantification in Lesions Within Bone and Susceptibility Artifact Regions
    Bezrukov, Ilja
    Schmidt, Holger
    Mantlik, Frederic
    Schwenzer, Nina
    Brendle, Cornelia
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (10) : 1768 - 1774
  • [43] Enhancing Cardiac PET by Motion Correction Techniques
    Rubeaux, Mathieu
    Doris, Mhairi K.
    Alessio, Adam
    Slomka, Piotr J.
    CURRENT CARDIOLOGY REPORTS, 2017, 19 (02)
  • [44] Five-Dimensional Respiratory and Cardiac Motion Compensation for Simultaneous PET/MR
    Rank, Christopher M.
    Heusser, Thorsten
    Wetscherek, Andreas
    Freitag, Martin T.
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [45] Cardiac MR imaging with external respirator: Synchronizing cardiac and respiratory motion - Feasibility study
    Plein, S
    Bulugahapitiya, S
    Jones, TR
    Bainbridge, GJ
    Ridgway, JP
    Sivananthan, MU
    RADIOLOGY, 2003, 227 (03) : 877 - 882
  • [46] Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
    Spangler-Bickell, Matthew G.
    Khalighi, Mohammad Mehdi
    Hoo, Charlotte
    DiGiacomo, Phillip Scott
    Maclaren, Julian
    Aksoy, Murat
    Rettmann, Dan
    Bammer, Roland
    Zaharchuk, Greg
    Zeineh, Michael
    Jansen, Floris
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 498 - 503
  • [47] The use of a generalized reconstruction by inversion of coupled systems (GRICS) approach for generic respiratory motion correction in PET/MR imaging
    Fayad, Hadi
    Odille, Freddy
    Schmidt, Holger
    Wuerslin, Christian
    Kuestner, Thomas
    Felblinger, Jacques
    Visvikis, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (06) : 2529 - 2546
  • [48] Respiratory- and cardiac motion-corrected simultaneous whole-heart PET and dual phase coronary MR angiography
    Munoz, Camila
    Neji, Radhouene
    Kunze, Karl P.
    Nekolla, Stephan G.
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1671 - 1684
  • [49] MR-Based Attenuation Correction for Brain PET Using 3-D Cycle-Consistent Adversarial Network
    Gong, Kuang
    Yang, Jaewon
    Larson, Peder E. Z.
    Behr, Spencer C.
    Hope, Thomas A.
    Seo, Youngho
    Li, Quanzheng
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (02) : 185 - 192
  • [50] MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition
    Han, Paul Kyu
    Horng, Debra E.
    Gong, Kuang
    Petibon, Yoann
    Kim, Kyungsang
    Li, Quanzheng
    Johnson, Keith A.
    El Fakhri, Georges
    Ouyang, Jinsong
    Ma, Chao
    MEDICAL PHYSICS, 2020, 47 (07) : 3064 - 3077