MR-based respiratory and cardiac motion correction for PET imaging

被引:60
|
作者
Kuestner, Thomas [1 ,2 ]
Schwartz, Martin [1 ,3 ]
Martirosian, Petros [3 ]
Gatidis, Sergios [2 ]
Seith, Ferdinand [2 ]
Gilliam, Christopher [4 ]
Blu, Thierry [4 ]
Fayad, Hadi [5 ]
Visvikis, Dimitris [5 ]
Schick, F. [3 ]
Yang, B. [1 ]
Schmidt, H. [2 ]
Schwenzer, N. F. [2 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Stuttgart, Germany
[2] Univ Tubingen, Dept Radiol, Tubingen, Germany
[3] Univ Tubingen, Sect Expt Radiol, Tubingen, Germany
[4] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
[5] Univ Bretagne, INSERM, U1101, LaTIM, Brest, France
关键词
PET/MR motion correction; Respiratory and cardiac motion correction; Image registration; Gadgetron; RECONSTRUCTION; TIME; NAVIGATOR; PET/MRI; HEART; LIVER; REGISTRATION; COMBINATION; MOVEMENTS; SEQUENCE;
D O I
10.1016/j.media.2017.08.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. Methods: A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). Results: A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. Conclusion: The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 144
页数:16
相关论文
共 50 条
  • [31] Joint cardiac and respiratory motion estimation for motion-corrected cardiac PET-MR
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Schuh, Andreas
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01)
  • [32] Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
    Matthias Hofmann
    Bernd Pichler
    Bernhard Schölkopf
    Thomas Beyer
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 93 - 104
  • [33] Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications
    Fayad, Hadi
    Schmidt, Holger
    Wuerslin, Christian
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (06) : 884 - 889
  • [34] Extended MRI-based PET motion correction for cardiac PET/MRI
    Aizaz, Mueez
    van der Pol, Jochem A. J.
    Schneider, Alina
    Munoz, Camila
    Holtackers, Robert J.
    van Cauteren, Yvonne
    van Langen, Herman
    Meeder, Joan G.
    Rahel, Braim M.
    Wierts, Roel
    Botnar, Rene M.
    Prieto, Claudia
    Moonen, Rik P. M.
    Kooi, M. Eline
    EJNMMI PHYSICS, 2024, 11 (01)
  • [35] Evaluation of three methods for delineation and attenuation estimation of the sinus region in MR-based attenuation correction for brain PET-MR imaging
    Jani Lindén
    Jarmo Teuho
    Mika Teräs
    Riku Klén
    BMC Medical Imaging, 22
  • [36] Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR
    Marin, Thibault
    Djebra, Yanis
    Han, Paul K.
    Chemli, Yanis
    Bloch, Isabelle
    El Fakhri, Georges
    Ouyang, Jinsong
    Petibon, Yoann
    Ma, Chao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [37] Pulmonary imaging using respiratory motion compensated simultaneous PET/MR
    Dutta, Joyita
    Huang, Chuan
    Li, Quanzheng
    El Fakhri, Georges
    MEDICAL PHYSICS, 2015, 42 (07) : 4227 - 4240
  • [38] Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI
    Marchesseau, Stephanie
    Totman, John J.
    Fadil, Hakim
    Leek, Francesca A. A.
    Chaal, Jasper
    Richards, Mark
    Chan, Mark
    Reilhac, Anthonin
    MEDICAL PHYSICS, 2019, 46 (02) : 726 - 737
  • [39] Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR
    Jang, Hyungseok
    Liu, Fang
    Bradshaw, Tyler
    McMillan, Alan B.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 2912 - 2922
  • [40] Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction
    Attenberger, Ulrike
    Catana, Ciprian
    Chandarana, Hersh
    Catalano, Onofrio A.
    Friedman, Kent
    Schonberg, Stefan A.
    Thrall, James
    Salvatore, Marco
    Rosen, Bruce R.
    Guimaraes, Alexander R.
    ABDOMINAL IMAGING, 2015, 40 (06): : 1374 - 1386