Changes in the pre-surgical treatment planning using conventional spiral tomography

被引:15
作者
Diniz, Ana Flavia N. [1 ]
Mendonca, Elismauro F. [1 ]
Leles, Claudio R. [1 ]
Guilherme, Aderico S. [1 ]
Cavalcante, Marcelo P. [1 ]
Silva, Maria Alves G. S. [1 ]
机构
[1] Univ Fed Goias, Fac Odontol, BR-74605220 Goiania, Go, Brazil
关键词
conventional spiral tomography; implant dentistry; treatment planning;
D O I
10.1111/j.1600-0501.2007.01475.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To investigate variation in the pre-surgical treatment planning after using conventional spiral tomography in addition to conventional radiographic exams. Material and methods: Twenty-nine partial or fully edentulous patients referred to implant therapy were selected and submitted to periapical, panoramic and conventional cross-sectional tomography exams. Pre-surgical treatment planning of 120 potential implant sites in 69 edentulous areas was performed by two independent experienced dental implant surgeons. After clinical examination, pre-surgical planning was made using only periapical and panoramic exams. Examiners were requested to reformulated initial planning after assessing tomographic images. Four treatment parameters were evaluated: length and width of implants, need of bone grafting and need of other surgical procedures. Results: Implant length and width remained unchanged in 60.2% and 87.2% of cases, respectively. No difference in length (P=0.576) and width (P=1) scores was observed in treatment planning with and without tomography. Variation in implant dimension was not affected by location of edentulous areas. Bone grafting and other surgical procedures significantly changed after tomograms (P < 0.001), independent of the location of edentulous areas. In 15.8% and 5.3% of cases bone grafting and other procedures were planned only after tomograms, respectively. Significant differences were observed in all maxillary and mandibular regions. Conclusion: Conventional spiral tomography plays an important role in pre-surgical treatment planning, increasing clinician's certainty of the need of additional surgical procedures (bone grafting, sinus lifting, and others) in pre-surgical treatment stage.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 28 条
[1]  
Almog Dov M, 2006, J Oral Implantol, V32, P77, DOI 10.1563/789.1
[2]   Displacement of the incisive foramen in conjunction with implant placement in the anterior maxilla without jeopardizing vitality of nasopalatine nerve and vessels: a novel surgical approach [J].
Artzi, Z ;
Nemcovsky, CE ;
Bitlitum, I ;
Segal, P .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) :505-510
[3]   Radiographic evaluation of mandibular posterior implant sites: Correlation between panoramic and tomographic determinations [J].
Bolin, A ;
Eliasson, S ;
vonBeetzen, M ;
Jansson, L .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) :354-359
[4]   A 5-year prospective study on small diameter screw-shaped oral implants [J].
Comfort, MB ;
Chu, FCS ;
Chai, J ;
Wat, PYP ;
Chow, TW .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) :341-345
[5]   Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible [J].
Dula, K ;
Mini, R ;
vanderStelt, PF ;
Lambrecht, JT ;
Schneeberger, P ;
Buser, D .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1996, 104 (5-6) :503-510
[6]  
Dula K, 2001, INT J ORAL MAX IMPL, V16, P80
[7]   Hypothetical mortality risk associated with spiral tomography of the maxilla and mandible prior to endosseous implant treatment [J].
Dula, K ;
Mini, R ;
Lambrecht, JT ;
vanderStelt, PF ;
Schneeberger, P ;
Clemens, G ;
Sanderink, H ;
Buser, D .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1997, 105 (02) :123-129
[8]   The use of tomography for dental implant planning [J].
Ekestubbe, A ;
Grondahl, K ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (04) :206-213
[9]   Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry [J].
Frei, C ;
Buser, D ;
Dula, K .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :490-497
[10]  
GARG SC, 1995, J SPACECR TECHNOL, V5, P11