Laboratory and Clinical Experience With a Diffractive Trifocal Intraocular Lens Sutured to an Artificial Iris

被引:7
作者
Mayer, Christian S. [1 ]
Son, Hyeck-Soo [1 ]
Labuz, Grzegorz [1 ]
Baur, Isabella D. [1 ]
Yildirim, Timur M. [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Res Ctr, David J Apple Int Lab Ocular Pathol & Int Vis Cor, INF 400, D-69120 Heidelberg, Germany
关键词
PUPIL SIZE; CONTRAST SENSITIVITY; OPTICAL-QUALITY; EXTENDED DEPTH; IMAGE QUALITY; DECENTRATION; IMPLANTATION; PERFORMANCE; FOCUS; TILT;
D O I
10.3928/1081597X-20211209-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine in vitro, using a translational re-search approach before realizing the procedure in a patient with iatrogenic aphakia and partial aniridia, whether suturing a trifocal intraocular lens (IOL) to an artificial iris degrades the IOL's optical quality. METHODS: Optical quality was analyzed by measuring the modulation transfer function (MTF) at a 3-mm aperture and at 50 and 100 lp/mm spatial frequencies. The FineVision Pod F GF IOL (PhysIOL) was assessed in two powers: two +20.00 diopters (D) (20A and 20B IOLs) and two +30.00 D (30A and 30B IOLs). The IOLs' decentration in relation to the artificial iris's center was evaluated. The laboratory results provided empirical evidence in the informed consent for surgical in-tervention in a patient with iatrogenic aphakia and iris de-fect in one eye. Clinical results were measured using the parameter of corrected distance visual acuity plus a patient self-assessment of the cosmetic appearance of the oper-ated eye. RESULTS: The 20A and 20B IOLs demonstrated a mean MTF reduction of up to 1.1%, whereas the 30A and 30B IOLs showed a decrease of up to 5.2% for both spatial frequencies. All lenses showed good centration levels. In the clinical case, the patient showed corrected distance visual acuity, distance -corrected near visual acuity, and distance-corrected interme-diate visual acuity of 0.20, 0.20, and 0.22 logMAR, respectively. The patient was satisfied with the cosmetic outcome. CONCLUSIONS: There was merely a slight reduction in trifo-cal IOL optical quality after it was sutured to an artificial iris. Clinically, the combined implantation of the artificial iris and FineVision IOL provided good functional and cosmetic outcomes. [J Refract Surg. 2022;38(1):61-68.]
引用
收藏
页码:61 / +
页数:11
相关论文
共 41 条
[1]   Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :430-438
[2]   Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs [J].
Artigas, Jose M. ;
Menezo, Jose L. ;
Peris, Cristina ;
Felipe, Adelina ;
Diaz-Llopis, Manuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2111-2117
[3]   Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations [J].
Baumeister, Martin ;
Buehren, Jens ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) :1006-1012
[4]   Unilateral Implantation of a new extended range of Vision Intraocular Lens in a young Patient [J].
Baur, Isabella D. ;
Auffarth, Gerd U. ;
Labuz, Grzegorz ;
Mayer, Christian S. ;
Khoramnia, Ramin .
OPHTHALMOLOGE, 2022, 119 (01) :65-70
[5]   Artificial Iris Implantation in a Patient with Iatrogenic Iris Defect Following Cataract Surgery [J].
Baur, Isabella Diana ;
Mayer, Christian S. ;
Storr, Julia ;
Khoramnia, Ramin .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2021, 238 (08) :875-877
[6]   Safety and efficacy of custom foldable silicone artificial iris implantation: prospective compassionate-use case series [J].
Bonnet, Clemence ;
Miller, Kevin M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (06) :893-901
[7]   Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intralocular lenses after cataract extraction Prospective 6-month study [J].
Cionni, Robert J. ;
Osher, Robert H. ;
Snyder, Michael E. ;
Nordlund, Michael L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) :1033-1039
[8]   History and development of the apodized diffractive intraocular lens [J].
Davison, James A. ;
Simpson, Michael J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :849-858
[9]   Hydrophilic intraocular lens opacification after posterior lamellar keratoplasty - a material analysis with special reference to optical quality assessment [J].
Giers, Bert C. ;
Tandogan, Tamer ;
Auffarth, Gerd U. ;
Choi, Chul Y. ;
Auerbach, Florian N. ;
Sel, Saadettin ;
Mayer, Christian ;
Khoramnia, Ramin .
BMC OPHTHALMOLOGY, 2017, 17
[10]   Stereoacuity and aniseikonia after unilateral and bilateral implantation of the Array refractive multifocal intraocular lens [J].
Häring, G ;
Gronemeyer, A ;
Hedderich, J ;
de Decker, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08) :1151-1156