摘要
An increase in hydrogen peroxide concentration in exhaled breath (EB) of patients, who suffer from some diseases related to the lung, function, has been observed and considered as a reliable indicator of lung diseases. In the EB of these patients, hydrogen peroxide is present in the vapour phase together with water, thus one of the approaches of monitoring hydrogen peroxide in the EB is to condense it and then to perform the hydrogen peroxide measurement in the condensate. Earlier, a hydrogen peroxide sensor based on an electrolyte metal oxide semiconductor field-effect transistor ((MOSFET)-M-E) has been investigated. The sensor shows the possibility to measure hydrogen peroxide at a concentration of micro-molar level. Due to its miniaturizability, the sensor is able to detect hydrogen peroxide in a small volume and is thus especially suitable for monitoring of hydrogen peroxide in the EB. In this paper, a simple set-up for condensation of hydrogen peroxide in the EB is introduced. The set-up consists of a cooling tube using a Peltier element for condensation of the exhaled breath air and the (MOSFET)-M-E-based hydrogen peroxide sensor. Using this cooling tube, primary results on the collection and measurement of hydrogen peroxide in artificial EB are given. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 12 条
[1]   Electroactive Gate Materials for a Hydrogen Peroxide Sensitive EMOSFET [J].
Anh, Dam T. V. ;
Olthuis, W. ;
Bergveld, P. .
IEEE SENSORS JOURNAL, 2002, 2 (01) :26-33
[2]   Transformation of a simple plastic into a superhydrophobic surface [J].
Erbil, HY ;
Demirel, AL ;
Avci, Y ;
Mert, O .
SCIENCE, 2003, 299 (5611) :1377-1380
[3]   ELECTRICAL WIRING OF REDOX ENZYMES [J].
HELLER, A .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (05) :128-134
[4]   Exhaled breath condensate: An evolving tool for noninvasive evaluation of lung disease [J].
Hunt, J .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2002, 110 (01) :28-34
[5]   Oxidative stress after lung resection therapy - A pilot study [J].
Lases, EC ;
Duurkens, VAM ;
Gerritsen, WBM ;
Haas, FJLM .
CHEST, 2000, 117 (04) :999-1003
[6]   Development of an ''electrically wired'' amperometric immunosensor for the determination of biotin based on a non-diffusional redox osmium polymer film containing an antibody to the enzyme label horseradish peroxidase [J].
Lu, B ;
Iwuoha, EI ;
Smyth, MR ;
OKennedy, R .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :59-66
[7]   Analysis of exhaled breath condensate for monitoring airway inflammation [J].
Montuschi, P ;
Barnes, PJ .
TRENDS IN PHARMACOLOGICAL SCIENCES, 2002, 23 (05) :232-237
[8]   Collection and analysis of exhaled breath condensate in humans [J].
Mutlu, GM ;
Garey, KW ;
Robbins, RA ;
Danziger, LH ;
Rubinstein, I .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (05) :731-737
[9]   Increased content of hydrogen peroxide in the expired breath of cigarette smokers [J].
Nowak, D ;
Antczak, A ;
Krol, M ;
Pietras, T ;
Shariati, B ;
Bialasiewicz, P ;
Jeczkowski, K ;
Kula, P .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (04) :652-657
[10]   Exhalation of H2O2 and thiobarbituric acid reactive substances (TBARS) by healthy subjects [J].
Nowak, D ;
Kalucka, S ;
Bialasiewicz, P ;
Król, M .
FREE RADICAL BIOLOGY AND MEDICINE, 2001, 30 (02) :178-186