Whole body [18F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: a preliminary prospective study

被引:96
作者
Bensimhon, L. [1 ]
Lavergne, T. [2 ]
Hugonnet, F. [1 ]
Mainardi, J. -L. [3 ]
Latremouille, C. [4 ]
Maunoury, C. [1 ]
Lepillier, A. [2 ]
Le Heuzey, J. -Y. [2 ]
Faraggi, M. [1 ]
机构
[1] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Nucl Med, Paris, France
[2] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Cardiol, Paris, France
[3] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Microbiol, Paris, France
[4] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Cardiovasc Surg, Paris, France
关键词
F-18-FDG; infection; pacemaker; PET-CT; FDG-PET;
D O I
10.1111/j.1469-0691.2010.03312.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
We studied the potential use of [F-18]fluorodeoxyglucose (F-18-FDG) whole body positron emission tomography (PET)-computed tomography for the diagnosis of device infection and extension of infection. Twenty-one patients with suspected device infection were prospectively included and compared with 14 controls free of infection. F-18-FDG uptake on the box and on the leads was visually and quantitatively interpreted (using the maximal standard uptake value). The final diagnosis was obtained either from bacteriological data after device culture (n = 11) or by a 6-month follow-up according to modified Duke's criteria (n = 10). Ten patients finally showed infection on bacteriological study (n = 8) or during follow-up (n = 2). Sensitivity, specificity, positive predictive value and negative predictive value were, respectively, 80%, 100%, 100% and 84.6% on patient-based analysis (presence or absence of infection). They were 100%, 100%, 100% and 100% for boxes, but only 60%, 100%, 100% and 73% for leads. Quantitative analysis could be useful for boxes but not for leads, for which the presence of a mild hot spot was the best criterion of infection. The four false negatives on leads received antibiotics for longer than the six true positives (20 +/- 7.2 vs. 3.2 +/- 2.3 days, p < 0.01). Although the study was not designed for this purpose, management could have been modified by PET results in six of 21 patients. F-18-FDG PET imaging may be useful for the diagnosis of device infection, and could impact on clinical management. Interpretation of negative cases should be performed with caution if patients have received antibiotics.
引用
收藏
页码:836 / 844
页数:9
相关论文
共 16 条
[1]  
ABIKHZER G, 2009, J NUCL CARDIOL, V16, P1532
[2]   PET-CT findings in large vessel vasculitis presenting as FUO, a case report [J].
Akin, Esma ;
Coen, Adam ;
Momeni, Mahnaz .
CLINICAL RHEUMATOLOGY, 2009, 28 (06) :737-738
[3]   F-18-FDG uptake in tuberculosis [J].
Bakheet, SMB ;
Powe, J ;
Ezzat, A ;
Rostom, A .
CLINICAL NUCLEAR MEDICINE, 1998, 23 (11) :739-742
[4]  
Bleeker-Rovers CP, 2003, NETH J MED, V61, P323
[5]  
COSTA A, 1998, ARCH MAL COEUR VAISS, V91, P753
[6]   Thromboembolism in Pulmonary Artery Sarcoma [J].
Farsad, Mohsen ;
Pernter, Patrizia ;
Triani, Antonio ;
Osele, Luzian ;
Wiedermann, Christian J. .
CLINICAL NUCLEAR MEDICINE, 2009, 34 (04) :239-240
[7]   Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: Comparison with computed tomographic findings [J].
Fukuchi, K ;
Ishida, Y ;
Higashi, M ;
Tsunekawa, T ;
Ogino, H ;
Minatoya, K ;
Kiso, K ;
Naito, H .
JOURNAL OF VASCULAR SURGERY, 2005, 42 (05) :919-925
[8]   Fluorine-18 fluorodeoxyglucose PET in infectious bone diseases:: results of histologically confirmed cases [J].
Kälicke, T ;
Schmitz, A ;
Risse, JH ;
Arens, S ;
Keller, E ;
Hansis, M ;
Schmitt, O ;
Biersack, HJ ;
Grünwald, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (05) :524-528
[9]  
Keidar Z, 2009, Q J NUCL MED MOL IM, V53, P35
[10]   Imaging Coronary Sinus Infection in Pacemaker Electrode with [18F]-Fluorodeoxyglucose Positron Emission Tomography [J].
Khamaisi, Mogher ;
Medina, Aharon ;
Mazouz, Benjamin ;
Bocher, Moshe .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (12) :1327-1328