A feasible study on using multiplexed sensitivity-encoding to reduce geometric distortion in diffusion-weighted echo planar imaging

被引:12
|
作者
Chen, Xinyuan [1 ,2 ]
Zhang, Ye [1 ,2 ]
Cao, Ying [1 ,2 ]
Sun, Rui [3 ]
Huang, Peng [1 ,2 ]
Xu, Yingjie [1 ,2 ]
Wang, Wenqing [1 ,2 ]
Feng, Qinfu [1 ,2 ]
Xiao, Jianping [1 ,2 ]
Yi, Junlin [1 ,2 ]
Li, Yexiong [1 ,2 ]
Dai, Jianrong [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Natl Canc Ctr, Natl Clin Res Ctr Canc, Canc Hosp, Beijing 100021, Peoples R China
[2] Peking Union Med Coll, Beijing 100021, Peoples R China
[3] Anhui Prov Taihe Cty Peoples Hosp, Fuyang, Anhui, Peoples R China
基金
国家重点研发计划; 美国国家科学基金会;
关键词
Multiplexed sensitivity-encoding; Diffusion-weighted echo planar imaging; Multi-shot acquisition; Geometric distortion; Brain radiotherapy; BRAIN METASTASES; FUNCTIONAL MRI; PROPELLER EPI; RESOLUTION; RADIOTHERAPY; IMAGES; ACQUISITIONS; CANCER; HEAD;
D O I
10.1016/j.mri.2018.08.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Single-shot (SS) echo planar imaging (EPI) is commonly used for diffusion-weighted imaging (DWI) in radiation treatment planning. The geometric distortion of single-shot diffusion-weighted EPI (SS-DWEPI) limits its utility in precision radiotherapy. We aimed to investigate the use of multiplexed sensitivity-encoding DWEPI (MUSE-DWEPI) to reduce the geometric distortions to allow its use in brain radiotherapy. Methods: In a phantom study, phantom diameters measured using MUSE-DWEPI and SS-DWEPI were compared and the percentages of geometric distortion (%GD) were calculated. The shifting vectors of control points were also plotted and calculated. In a patient study, ten patients (six with post-surgery glioma, four with brain metastases) requiring MRI were enrolled, and the image distortion levels in SS-DWEPI and MUSE-DWEPI were compared using T2 Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (T2 PROPELLER) images as the reference. The tumor targets and four brain regions were delineated based on T2 PROPELLER, SS-DWEPI, and MUSE-DWEPI, using the Dice similarity coefficient (DSC) and the Hausdorff distance (HD) to quantify the level of geometric distortion. Results: In the phantom study, the most prominent image distortion was along the phase encoding direction in terms of %GD fluctuated from 7%-8% for SS-DWEPI (b = 0 s/mm(2) and 1000 s/mm(2)) and fluctuated from 2%-3% for MUSE-DWEPI (b = 0 s/mm(2) and 1000 s/mm(2)) with different positions and b values. The mean relative displacement of all control points was 4.45 +/- 3.44 mm for SS-DWEPI 130 and 2.17 +/- 1.9 mm for MUSE-DWEPI b(0) close to the isocenter. Increasing the distance away from the isocenter in the z direction, the distortion increased more in SS-DWEPI. For all brain regions and targets involved, higher DSC values and lower HDs were obtained using MUSE-DWEPI than with SS-DWEPI (p < .01). The mean improvement in HD when switching from SS-DWEPI to MUSE-DWEPI was 3.65 +/- 1.31 mm. Conclusions: MUSE-DWEPI is an improvement upon SS-DWEPI in geometric distortion reduction, which might be a promising application strategy for DWI in radiotherapy.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 50 条
  • [1] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Wang, Xiuyu
    Wang, Peng
    Zhang, Heng
    Wang, Xian
    Shi, Jie
    Hu, Shudong
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (03) : 268 - 275
  • [2] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Xiuyu Wang
    Peng Wang
    Heng Zhang
    Xian Wang
    Jie Shi
    Shudong Hu
    Japanese Journal of Radiology, 2024, 42 : 268 - 275
  • [3] Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique
    Nasu, K
    Kuroki, Y
    Kuroki, S
    Murakami, K
    Nawano, S
    Moriyama, N
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2004, 34 (10) : 620 - 626
  • [4] Diffusion-Weighted Echo Planar Imaging using MUltiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head and Neck Cancer: An Initial Study
    Konar, Amaresha Shridhar
    Fung, Maggie
    Paudyal, Ramesh
    Oh, Jung Hun
    Mazaheri, Yousef
    Hatzoglou, Vaios
    Shukla-Dave, Amita
    TOMOGRAPHY, 2020, 6 (02) : 231 - 240
  • [5] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [6] Multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE) in diffusion-weighted imaging for rectal MRI: a quantitative and qualitative analysis at multiple b-values
    El Homsi, Maria
    Bates, David D. B.
    Mazaheri, Yousef
    Sosa, Ramon
    Gangai, Natalie
    Petkovska, Iva
    ABDOMINAL RADIOLOGY, 2023, 48 (02) : 448 - 457
  • [7] Multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE) in diffusion-weighted imaging for rectal MRI: a quantitative and qualitative analysis at multiple b-values
    Maria El Homsi
    David D. B. Bates
    Yousef Mazaheri
    Ramon Sosa
    Natalie Gangai
    Iva Petkovska
    Abdominal Radiology, 2023, 48 : 448 - 457
  • [8] Rice Pads Reduce Geometric Distortion of Echo-planar Diffusion-weighted Images of the Cervical Spinal Cord
    Moriya, Susumu
    Miki, Yukio
    Yokobayashi, Tsuneo
    Kanagaki, Mitsunori
    Komori, Yoshiaki
    Fujimoto, Koji
    Ishikawa, Mitsunori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (01) : 65 - 69
  • [9] High-resolution Diffusion-weighted Imaging of the Prostate Using Multiplexed Sensitivity-encoding: Comparison with the Conventional and Reduced Field-of-view Techniques
    Nakamoto, Atsushi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Fukui, Hideyuki
    Ota, Takashi
    Yano, Keigo
    Kiso, Kengo
    Honda, Toru
    Tarewaki, Hiroyuki
    Koyama, Yoshihiro
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2025, 24 (01) : 58 - 65
  • [10] Assessing Image Quality in Multiplexed Sensitivity-Encoding Diffusion-Weighted Imaging with Deep Learning-Based Reconstruction in Bladder MRI
    Cha, Seung Ha
    Han, Yeo Eun
    Han, Na Yeon
    Kim, Min Ju
    Park, Beom Jin
    Sim, Ki Choon
    Sung, Deuk Jae
    Yoo, Seulki
    Lan, Patricia
    Guidon, Arnaud
    DIAGNOSTICS, 2025, 15 (05)