摘要
Background: Clinical methods of assessing adequacy of the circulation are poor predictors of volume of blood flow in the newborn preterm. Doppler echocardiography can be used to assess perfusion at various sites in the circulation. Objective: To assess repeatability of measurement of volume of superior vena caval (SVC) and descending aortic (DAo) flow. Design: SVC and DAo flow volume were assessed four times in the first 48 h of postnatal life in a cohort of preterm (<31 weeks) infants. Within-observer and between-observer repeatability was assessed in a subgroup of preterm infants. Normative values were derived from 14 preterm infants who required <48 h respiratory support and 13 healthy term infants. Results: Within-observer repeatability coefficient was 30 ml/kg/min for quantification of SVC flow, and 2.2 cm for DAo stroke distance. Measurement of DAo diameter had poor repeatability. Between-observer repeatability appeared poorer than within-observer repeatability. The fifth centile for volume of SVC flow in healthy preterm infants was 55 ml/kg/min and 4.5 cm for DAo stroke distance. Conclusions: Echocardiographic assessments of volume of SVC flow and velocity of DAo flow have similar within-observer repeatability to other neonatal haemodynamic measurements. Between-observer repeatability for both measurements was poor, reflecting the difficulty of standardising these novel techniques. In this small cohort of preterm infants, SVC flow volume <55 ml/kg/min and DAo stroke distance <4.5 cm represented low or borderline systemic perfusion in the first 48 h of postnatal life.
引用
收藏
页码:F24 / F28
页数:5
相关论文
共 31 条
[1]   Project 27/28: Inquiry into quality of neonatal care and its effect on the survival of infants who were born at 27 and 28 weeks in England, Wales, and Northern Ireland [J].
Acolet, D ;
Elbourne, D ;
McIntosh, N ;
Weindling, M ;
Korkodilos, M ;
Haviland, J ;
Modder, J ;
Macintosh, M .
PEDIATRICS, 2005, 116 (06) :1457-1465
[2]   NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN [J].
ALVERSON, DC ;
ELDRIDGE, M ;
DILLON, T ;
YABEK, SM ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1982, 101 (01) :46-50
[3]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature [J].
Chew, MS ;
Poelaert, J .
INTENSIVE CARE MEDICINE, 2003, 29 (11) :1889-1894
[6]   CARDIAC-OUTPUT DETERMINATIONS IN THE NEWBORN - REPRODUCIBILITY OF THE PULSED DOPPLER VELOCITY-MEASUREMENT [J].
CLAFLIN, KS ;
ALVERSON, DC ;
PATHAK, D ;
ANGELUS, P ;
BACKSTROM, C ;
WERNER, S .
JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (06) :311-315
[7]   Hypotension in the very low birthweight infant: the old, the new, and the uncertain [J].
Dasgupta, SJ ;
Gill, AB .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2003, 88 (06) :F450-F454
[8]   ASSESSMENT OF DUCTUS-ARTERIOSUS SHUNT IN PRETERM INFANTS SUPPORTED BY MECHANICAL VENTILATION - EFFECT OF INTERATRIAL SHUNTING [J].
EVANS, N ;
IYER, P .
JOURNAL OF PEDIATRICS, 1994, 125 (05) :778-785
[9]   INCOMPETENCE OF THE FORAMEN OVALE IN PRETERM INFANTS SUPPORTED BY MECHANICAL VENTILATION [J].
EVANS, N ;
IYER, P .
JOURNAL OF PEDIATRICS, 1994, 125 (05) :786-792
[10]   LONGITUDINAL CHANGES IN THE DIAMETER OF THE DUCTUS-ARTERIOSUS IN VENTILATED PRETERM INFANTS - CORRELATION WITH RESPIRATORY OUTCOMES [J].
EVANS, N ;
IYER, P .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1995, 72 (03) :F156-F161