Two-dimensional speckle tracking echocardiography: standardization efforts based on synthetic ultrasound data

被引:64
作者
D'hooge, Jan [1 ]
Barbosa, Daniel [1 ]
Gao, Hang [1 ]
Claus, Piet [1 ]
Prater, David [2 ]
Hamilton, Jamie [3 ]
Lysyansky, Peter [4 ]
Abe, Yasuhiko [5 ]
Ito, Yasuhiro [6 ]
Houle, Helene [7 ]
Pedri, Stefano [8 ]
Baumann, Rolf [9 ]
Thomas, James [10 ]
Badano, Luigi P. [11 ]
机构
[1] Univ Leuven, Dept Cardiovasc Sci, Herestr 49, B-3000 Leuven, Belgium
[2] Philips Med Syst, Andover, MA USA
[3] Epsilon Imaging, Ann Arbor, MI USA
[4] GE Healthcare, Tel Aviv, Israel
[5] Toshiba Med Syst Corp, Otawara Shi, Tochigi, Japan
[6] Hitachi Aloka Med, Tokyo, Japan
[7] Siemens Ultrasound, Mountain View, CA USA
[8] Esaote, Genoa, Italy
[9] TomTec Imaging Syst, Unterschleissheim, Germany
[10] Northwestern Univ, Bluhm Cardiovasc Inst, Chicago, IL 60611 USA
[11] Univ Padua, Padua, Italy
关键词
speckle tracking echocardiography; variability; standardization; cardiac function; EACVI/ASE/INDUSTRY TASK-FORCE; CONSENSUS DOCUMENT; COMMON STANDARD; LEFT-VENTRICLE; DEFORMATION; STRAIN; DEFINITIONS;
D O I
10.1093/ehjci/jev197
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Speckle tracking echocardiography has already demonstrated its clinical potential. However, its use in routine practice is jeopardized by recent reports on high inter-vendor variability of the measurements. As such, the European Association of CardioVascular Imaging (EACVI) and the American Society of Echocardiography (ASE) set up a standardization task force, which was joined by all manufacturers of echocardiographic equipment as well as by companies offering software solutions only, with the ambition to tackle this problem by standardization and quality assurance (QA). Methods and results In this study, a first step towards QA of all commercially available tracking solutions based on computer-generated ultrasound images is presented. The accuracy of the products was acceptable with relative errors below 10% and intra-vendor reproducibility within 5%. Conclusion Whether these results can be extrapolated to the clinical setting is the topic of an ongoing study of the EACVI/ASE/Industry Task Force to standardize deformation imaging. This study was an important first step in the development of generally accepted tools for QA of speckle tracking echocardiography.
引用
收藏
页码:693 / 701
页数:9
相关论文
共 14 条
  • [1] A Pipeline for the Generation of Realistic 3D Synthetic Echocardiographic Sequences: Methodology and Open-Access Database
    Alessandrini, M.
    De Craene, M.
    Bernard, O.
    Giffard-Roisin, S.
    Allain, P.
    Waechter-Stehle, I.
    Weese, J.
    Saloux, E.
    Delingette, H.
    Sermesant, M.
    D'hooge, J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (07) : 1436 - 1451
  • [2] DESCRIPTION OF THE DEFORMATION OF THE LEFT-VENTRICLE BY A KINEMATIC MODEL
    ARTS, T
    HUNTER, WC
    DOUGLAS, A
    MUIJTJENS, AMM
    RENEMAN, RS
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (10) : 1119 - 1127
  • [3] De Craene M., 2014, P ISBI 2014, P73
  • [4] Head-to-Head Comparison of Global Longitudinal Strain Measurements among Nine Different Vendors The EACVI/ASE Inter-Vendor Comparison Study
    Farsalinos, Konstantinos E.
    Daraban, Ana M.
    Unlu, Serkan
    Thomas, James D.
    Badano, Luigi P.
    Voigt, Jens-Uwe
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (10) : 1171 - +
  • [5] A Fast Convolution-Based Methodology to Simulate 2-D/3-D Cardiac Ultrasound Images
    Gao, Hang
    Choi, Hon Fai
    Claus, Piet
    Boonen, Steven
    Jaecques, Siegfried
    van Lenthe, G. Harry
    Van der Perre, Georges
    Lauriks, Walter
    D'hooge, Jan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) : 404 - 409
  • [6] Current State of Three-Dimensional Myocardial Strain Estimation Using Echocardiography
    Jasaityte, Ruta
    Heyde, Brecht
    D'hooge, Jan
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (01) : 15 - 28
  • [7] Comparison between Different Speckle Tracking and Color Tissue Doppler Techniques to Measure Global and Regional Myocardial Deformation in Children
    Koopman, Laurens P.
    Slorach, Cameron
    Hui, Wei
    Manlhiot, Cedric
    McCrindle, Brian W.
    Friedberg, Mark K.
    Jaeggi, Edgar T.
    Mertens, Luc
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 919 - 928
  • [8] Marwick TH, 2008, MYOCARDIAL IMAGING T
  • [9] TEXTURE OF B-MODE ECHOGRAMS - 3-D SIMULATIONS AND EXPERIMENTS OF THE EFFECTS OF DIFFRACTION AND SCATTERER DENSITY
    OOSTERVELD, BJ
    THIJSSEN, JM
    VERHOEF, WA
    [J]. ULTRASONIC IMAGING, 1985, 7 (02) : 142 - 160
  • [10] Normal Range of Left Ventricular 2-Dimensional Strain - Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) Study
    Takigiku, Kiyohiro
    Takeuchi, Masaaki
    Izumi, Chisato
    Yuda, Satoshi
    Sakata, Konomi
    Ohte, Nobuyuki
    Tanabe, Kazuaki
    Nakatani, Satoshi
    [J]. CIRCULATION JOURNAL, 2012, 76 (11) : 2623 - 2632