A method for optimal sizing energy storage systems for microgrids

被引:239
作者
Fossati, Juan P. [1 ]
Galarza, Ainhoa
Martin-Villate, Ander
Fontan, Luis
机构
[1] Univ Navarra, CEIT, Dept Elect & Commun, Donostia San Sebastian 20018, Spain
关键词
Energy storage sizing; Microgrid; Battery lifetime model; Fuzzy expert system; Genetic algorithm; Energy management strategy; MANAGEMENT; TECHNOLOGY; OPERATION; ALGORITHM; POWER;
D O I
10.1016/j.renene.2014.12.039
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper proposes a genetic algorithm-based method for sizing the energy storage system (ESS) in microgrids. The main goal of the proposed method is to find the energy and power capacities of the storage system that minimizes the operating cost of the microgrid. The energy management strategy (EMS) used in this paper is based on a fuzzy expert system which is responsible for setting the power output of the ESS. The design of the EMS is carried out by means of a genetic algorithm that is used to set the fuzzy rules and membership functions of the expert system. Given that the size of the storage system has a major influence on the energy management strategy, in this paper the EMS and ESS capacities are jointly optimized. In addition, the proposed method uses an aging model to predict the lifetime of the ESS. In this way it is possible to determine the cost associated with energy storage in a more precise manner. The unit commitment problem, which is crucial for the proper operation of the microgrid, has been also considered in the present work. The suggested sizing methodology has been validated in two case studies. (c) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:539 / 549
页数:11
相关论文
共 36 条
[1]   Microgrid management with a quick response optimization algorithm for active power dispatch [J].
Alvarez, Eduardo ;
Campos, Antonio M. ;
Arboleya, Pablo ;
Gutierrez, Antonio J. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) :465-473
[2]  
[Anonymous], ELECT STORAGE RENEWA
[3]  
[Anonymous], SES6019864
[4]  
[Anonymous], OPERATION OPTIMIZATI
[5]  
[Anonymous], 2012, Power Generation, Operation, and Control
[6]  
[Anonymous], 2012, P 2012 IEEE POW EN S
[7]  
[Anonymous], FUZZY SETS SYST
[8]  
[Anonymous], L16RE 2V DEEP CYCLE
[9]  
[Anonymous], BATTERY ENERGY STORA
[10]   Optimal sizing of battery energy storage for micro-grid operation management using a new improved bat algorithm [J].
Bahmani-Firouzi, Bahman ;
Azizipanah-Abarghooee, Rasoul .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 56 :42-54