Integrated water quality monitoring system with pH, free chlorine, and temperature sensors

被引:66
作者
Qin, Yiheng [1 ]
Alam, Arif U. [1 ,2 ]
Pan, Si [3 ]
Howlader, Matiar M. R. [1 ]
Ghosh, Raja [3 ]
Hu, Nan-Xing [2 ]
Jin, Hao [1 ,4 ]
Dong, Shurong [4 ]
Chen, Chih-Hung [1 ]
Deen, M. Jamal [1 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] Xerox Res Ctr Canada Ltd, Adv Mat Lab, 2660 Speakman Dr, Mississauga, ON L5K 2L1, Canada
[3] McMaster Univ, Dept Chem Engn, 1280 Main St West, Hamilton, ON L8S 4L7, Canada
[4] Zhejiang Univ, Coll Informat Sci & Elect Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Inkjet printing; Integration; pH; Free chlorine; Temperature; Water quality monitoring; Sensor; PALLADIUM/PALLADIUM OXIDE; MULTISENSOR SYSTEM; MICROSENSORS; ELECTRODES; THERAPY;
D O I
10.1016/j.snb.2017.07.188
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate, efficient, inexpensive, and multi-parameter monitoring of water quality parameters is critical for continued water safety from developed urban regions to resource-limited or sparsely populated areas. This study describes an integrated sensing system with solution-processed pH, free chlorine, and temperature sensors on a common glass substrate. The pH and temperature sensors are fabricated by low-cost inkjet printing of palladium/palladium oxide and silver. The potentiometric pH sensor has a high sensitivity of 60.6 mV/pH and a fast response of 15 s. The Wheatstone-bridge-based temperature sensor shows an immediate response of 3.35 mv/degrees C towards temperature change. The free chlorine sensor is based on an electrochemically modified pencil lead, which exhibits a stable and reproducible sensitivity of 342 nA/ppm for hypochlorous acid. Such a free chlorine sensor is potentiostat-free and calibration free, so it is easy-to-use. The three sensors are connected to a field-programmable gate array board for data collection, analysis and display, with real-time pH and temperature compensation for free chlorine sensing. The developed sensing system is user-friendly, cost-effective, and can monitor water samples in real-time with an accuracy of >82%. This platform enables water quality monitoring by nonprofessionals in a simple manner. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:781 / 790
页数:10
相关论文
共 40 条
  • [1] [Anonymous], 2018, Guidelines for Drinking Water Quality
  • [2] Electrochemical Biosensors for pollutants in the environment
    Badihi-Mossberg, Michal
    Buchner, Virginia
    Rishpon, Judith
    [J]. ELECTROANALYSIS, 2007, 19 (19-20) : 2015 - 2028
  • [3] Online Drinking Water Quality Monitoring: Review on Available and Emerging Technologies
    Banna, Muinul H.
    Imran, Syed
    Francisque, Alex
    Najjaran, Homayoun
    Sadiq, Rehan
    Rodriguez, Manuel
    Hoorfar, Mina
    [J]. CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2014, 44 (12) : 1370 - 1421
  • [4] Miniaturized water quality monitoring pH and conductivity sensors
    Banna, Muinul H.
    Najjaran, Homayoun
    Sadiq, Rehan
    Imran, Syed A.
    Rodriguez, Manuel J.
    Hoorfar, Mina
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 434 - 441
  • [5] Chapman D., 2021, Water Quality Assessments: A Guide to the Use of Biota, Sediments and Water in Environmental Monitoring, V2nd, DOI [10.1201/9781003062103, DOI 10.1201/9781003062103]
  • [6] Connell G.F., 1996, WATER DISINFECTION S
  • [7] Feng YG, 2007, J ENVIRON ENG SCI, V6, P277, DOI 10.1139/s06-052
  • [8] Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
    Gao, Wei
    Emaminejad, Sam
    Nyein, Hnin Yin Yin
    Challa, Samyuktha
    Chen, Kevin
    Peck, Austin
    Fahad, Hossain M.
    Ota, Hiroki
    Shiraki, Hiroshi
    Kiriya, Daisuke
    Lien, Der-Hsien
    Brooks, George A.
    Davis, Ronald W.
    Javey, Ali
    [J]. NATURE, 2016, 529 (7587) : 509 - +
  • [9] IMPROVEMENTS IN THE N,N-DIETHYL-P-PHENYLENEDIAMINE METHOD FOR THE DETERMINATION OF FREE AND COMBINED RESIDUAL CHLORINE THROUGH THE USE OF FIA
    GORDON, G
    SWEETIN, DL
    SMITH, K
    PACEY, GE
    [J]. TALANTA, 1991, 38 (02) : 145 - 149
  • [10] Wearable, Human-Interactive, Health-Monitoring, Wireless Devices Fabricated by Macroscale Printing Techniques
    Honda, Wataru
    Harada, Shingo
    Arie, Takayuki
    Akita, Seiji
    Takei, Kuniharu
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2014, 24 (22) : 3299 - 3304