Does left atrial appendage (LAA) occlusion device alter the echocardiography and electrocardiogram parameters in patients with atrial fibrillation?

被引:3
作者
Jie, Qiqiang [1 ]
Wang, Dongzhi [1 ]
Liu, Baoxin [1 ]
Zhao, Dongdong [1 ]
Li, Yong [1 ]
Luo, Jiachen [1 ]
Dai, Liming [1 ]
Li, Shuang [1 ]
Xu, Yawei [1 ]
Wei, Yidong [1 ]
机构
[1] Tongji Univ, Sch Med, Dept Cardiol, Shanghai Peoples Hosp 10, 301 Yanchang Rd, Shanghai 200072, Peoples R China
关键词
Echocardiography; Electrocardiogram; Atrial fibrillation; Left atrial appendage occlusion; CONGESTIVE-HEART-FAILURE; WARFARIN THERAPY; SIZE; STROKE; ENLARGEMENT; MORTALITY; RISK; PREDICTORS; PREVENTION; DURATION;
D O I
10.1016/j.ijcard.2016.03.204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The alterations of echocardiography and electrocardiogram(ECG) in patients received left atrial appendage LAA occlusion therapy are still unclear. The present study was to evaluate the influence of LAA occlusion device on echocardiography and ECG changes in patients with atrial fibrillation (AF). Methods: Seventy-three patients who had undergone Watchman, LAmbre and Lefort were enrolled in this study. Echocardiography and ECG results at pre- and post-operation were collected. Besides, echocardiography was also performed during follow-up visits at 1, 6 and 12 months after discharge. Results: After LAA occlusion, a slight and measureable movement of QRS electric axis was observed in most patients. The significant differences were also observed in heart rate (HR) and the mean-mean QT interval between pre- and post-operation for all patients. There existed no significant difference in echocardiographic parameters between before and after device implantation. However, a larger left atrial (LA) diameter was detected by echocardiography during follow-up visit at 6 months when compared with pre-operation parameters. Similarly, aortic root diameter (ARD) was also larger during follow-up at 12 months than the baseline dimension in preoperation. Conclusions: LAA occlusion device resulted in a slightly movement in QRS axis, reduced HR and increased the mean-mean QT interval duration. In addition, LA diameter and ARD seemed to be larger after device implantation. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:494 / 501
页数:8
相关论文
共 35 条
  • [1] Incident atrial fibrillation and mortality in older adults with heart failure
    Ahmed, A
    Perry, GJ
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2005, 7 (07) : 1118 - 1121
  • [2] ANDERSON DC, 1992, ANN INTERN MED, V116, P6
  • [3] The Clinical Profile and Pathophysiology of Atrial Fibrillation Relationships Among Clinical Features, Epidemiology, and Mechanisms
    Andrade, Jason
    Khairy, Paul
    Dobrev, Dobromir
    Nattel, Stanley
    [J]. CIRCULATION RESEARCH, 2014, 114 (09) : 1453 - 1468
  • [4] ESTIMATION OF LEFT-VENTRICULAR FILLING PRESSURES USING 2-DIMENSIONAL AND DOPPLER-ECHOCARDIOGRAPHY IN ADULT PATIENTS WITH CARDIAC DISEASE - ADDITIONAL VALUE OF ANALYZING LEFT ATRIAL SIZE, LEFT ATRIAL EJECTION FRACTION AND THE DIFFERENCE IN DURATION OF PULMONARY VENOUS AND MITRAL FLOW VELOCITY AT ATRIAL CONTRACTION
    APPLETON, CP
    GALLOWAY, JM
    GONZALEZ, MS
    GABALLA, M
    BASNIGHT, MA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) : 1972 - 1982
  • [5] LEFT ATRIAL SIZE AND THE RISK OF STROKE AND DEATH - THE FRAMINGHAM HEART-STUDY
    BENJAMIN, EJ
    DAGOSTINO, RB
    BELANGER, AJ
    WOLF, PA
    LEVY, D
    [J]. CIRCULATION, 1995, 92 (04) : 835 - 841
  • [6] Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy 5-Year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study
    Block, Peter C.
    Burstein, Steven
    Casale, Paul N.
    Kramer, Paul H.
    Teirstein, Paul
    Williams, David O.
    Reisman, Mark
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (07) : 594 - 600
  • [7] Anticoagulants for atrial fibrillation: Why is the treatment rate so low?
    Buckingham, TA
    Hatala, R
    [J]. CLINICAL CARDIOLOGY, 2002, 25 (10) : 447 - 454
  • [8] Camm AJ, 2012, EUROPACE, V14, P1385, DOI [10.1093/europace/eus305, 10.1093/eurheartj/ehs253]
  • [9] ATRIAL SIZE, ATRIAL-FIBRILLATION, AND STROKE
    CAPLAN, LR
    DCRUZ, I
    HIER, DB
    REDDY, H
    SHAH, S
    [J]. ANNALS OF NEUROLOGY, 1986, 19 (02) : 158 - 161
  • [10] Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
    Cotter, Paul E.
    Martin, Peter J.
    Ring, Liam
    Warburton, Elizabeth A.
    Belham, Mark
    Pugh, Peter J.
    [J]. NEUROLOGY, 2013, 80 (17) : 1546 - 1550