Patient-Specific Radiation Dose and Cancer Risk Estimation in Pediatric Chest CT: A Study in 30 Patients

被引:0
|
作者
Lia, Xiang [1 ,2 ,3 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ]
Segars, W. Paul [1 ,2 ,3 ]
Sturgeon, Gregory M. [2 ,3 ]
Colsher, James G. [1 ,3 ]
Frush, Donald P. [1 ,3 ]
机构
[1] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Phys, Durham, NC 27705 USA
[5] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
关键词
com puted t omography; C T; chest; pediatric; or gan dose; effective dose; cancer risk; effective risk; patient-specific; Monte Carlo; ORGAN;
D O I
10.1117/12.845491
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides radiation dose and cancer risk estimates specific to each patient and each CT examination. Recently, we reported a method for estimating patient-specific dose from pediatric chest CT. The purpose of this study is to extend that effort to patient-specific risk estimation and to a population of pediatric CT patients. Our study included thirty pediatric CT patients (16 males and 14 females; 0-16 years old), for whom full-body computer models were recently created based on the patients' clinical CT data. Using a validated Monte Carlo program, organ dose received by the thirty patients from a chest scan protocol (LightSpeed VCT, 120 kVp, 1.375 pitch, 40-mm collimation, pediatric body scan field-of-view) was simulated and used to estimate patient-specific effective dose. Risks of cancer incidence were calculated for radiosensitive organs using gender-, age-, and tissue-specific risk coefficients and were used to derive patientspecific effective risk. The thirty patients had normalized effective dose of 3.7-10.4 mSv/100 mAs and normalized effective risk of 0.5-5.8 cases/1000 exposed persons/100 mAs. Normalized lung dose and risk of lung cancer correlated strongly with average chest diameter (correlation coefficient: r = -0.98 to -0.99). Normalized effective risk also correlated strongly with average chest diameter (r = -0.97 to -0.98). These strong correlations can be used to estimate patient-specific dose and risk prior to or after an imaging study to potentially guide healthcare providers in justifying CT examinations and to guide individualized protocol design and optimization.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    RADIOLOGY, 2011, 259 (03) : 862 - 874
  • [2] Patient-specific dose estimation for pediatric chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    MEDICAL PHYSICS, 2008, 35 (12) : 5821 - 5828
  • [3] Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    MEDICAL PHYSICS, 2011, 38 (01) : 408 - 419
  • [4] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    CIRCULATION, 2005, 111 (01) : 83 - 89
  • [5] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Susan D. Kost
    Nicholas D. Fraser
    Diana E. Carver
    David R. Pickens
    Ronald R. Price
    Marta Hernanz-Schulman
    Michael G. Stabin
    Pediatric Radiology, 2015, 45 : 1771 - 1780
  • [6] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Kost, Susan D.
    Fraser, Nicholas D.
    Carver, Diana E.
    Pickens, David R.
    Price, Ronald R.
    Hernanz-Schulman, Marta
    Stabin, Michael G.
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1771 - 1780
  • [7] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [8] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    European Radiology, 2016, 26 : 2646 - 2655
  • [9] Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    MEDICAL PHYSICS, 2011, 38 (01) : 397 - 407
  • [10] A framework for analytical estimation of patient-specific CT dose
    Youn, Hanbean
    Kim, Jin Woo
    Jeon, Hosang
    Nam, Jiho
    Yun, Seungman
    Cho, Min Kook
    Kim, Ho Kyung
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783