Evaluating perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) removal across granular activated carbon (GAC) filter-adsorbers in drinking water treatment plants

被引:23
作者
Yuan, Jie [1 ]
Mortazavian, Soroosh [1 ]
Passeport, Elodie [1 ,2 ]
Hofmann, Ron [1 ]
机构
[1] Univ Toronto, Dept Civil & Mineral Engn, 35 St George St, Toronto, ON M5S 1A4, Canada
[2] Univ Toronto, Dept Chem Engn & Appl Chem, 200 Coll St, Toronto, ON M5S 3E5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Granular activated carbon; PFOA; PFOS; Adsorption; Biodegradation; POLYFLUOROALKYL SUBSTANCES PFASS; PILOT-SCALE; ADSORPTION CAPACITY; PERFLUOROALKYL; FATE; BIODEGRADATION; GROUNDWATER; SURFACTANTS; PRECURSORS; SULFONATE;
D O I
10.1016/j.scitotenv.2022.156406
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Granular activated carbon (GAC) was harvested from six filter-adsorbers that are used for taste and odour control in three drinking water treatment plants in Ontario, Canada, and evaluated for the removal of perfluorooctanic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) using minicolumn tests under different operational conditions. Parallel column tests were conducted using unsterilized GAC and sterilized GAC to distinguish adsorption from potential biodegradation of PFOA and PFOS across the GAC. It was observed that the GAC could achieve approximately 20% to 55% of PFOA and PFOS removal even after a long period of GAC operation (e.g., 6 years). There was no evidence of PFOA and PFOS biodegradation, so the removal in GAC can be attributed solely to adsorption under the conditions tested. However, in one location, there was evidence suggesting both removal and formation of PFOS and PFOA across the GAC, with the formation presumably due to the biotransformation of pre-existing precursors in the source water. Additionally, GAC service time and empty bed contact time (EBCT) were identified to be important factors that could affect the removal of PFOA and PFOS. Based on this information, an empirical model was proposed to predict PFOA and PFOS removal in GAC filter-adsorbers as a function of GAC service time and EBCT. This study provides useful information for utilities that have installed GAC for taste and odour control but may consider per-and polyfluoroalkyl substances (PFAS) removal as an additional voluntary objective or due to more stringent guidelines.
引用
收藏
页数:9
相关论文
共 53 条
[11]  
EASA, 2019, Type-certificate data sheet for Trent 1000 series engines
[12]  
EPA, 2016, EPA 800-F-16-003, PFOA & PFOS DRINKING WATER HEALTH ADVISORIES
[13]  
Franke V, 2019, ENVIRON SCI-WAT RES, V5, P1836, DOI [10.1039/c9ew00286c, 10.1039/C9EW00286C]
[14]   Removal of poly- and perfluoroalkyl substances (PFAS) from water by adsorption: Role of PFAS chain length, effect of organic matter and challenges in adsorbent regeneration [J].
Gagliano, Erica ;
Sgroi, Massimiliano ;
Falciglia, Pietro P. ;
Vagliasindi, Federico G. A. ;
Roccaro, Paolo .
WATER RESEARCH, 2020, 171
[15]  
Gillogly TET, 1999, J AM WATER WORKS ASS, V91, P98
[16]  
GRAESE SL, 1987, J AM WATER WORKS ASS, V79, P64
[17]  
Health Canada, 2018, GUIDELINES CANADIAN
[18]   Defluorination of Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS) by Acidimicrobium sp. Strain A6 [J].
Huang, Shan ;
Jaffe, Peter R. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (19) :11410-11419
[19]  
Huang YF, 2019, ENVIRON SCI-WAT RES, V5, P609, DOI [10.1039/C8EW00600H, 10.1039/c8ew00600h]
[20]  
Kempisty David M., 2022, AWWA Water Sci., V4, pe1269