Electrochemical Detection of Hydrazine Using Poly(dopamine)-Modified Electrodes

被引:35
|
作者
Lee, Ji Young [1 ]
Truc Ly Nguyen [2 ]
Park, Jun Hui [3 ]
Kim, Byung-Kwon [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Chem, Daejeon 34141, South Korea
[2] Sookmyung Womens Univ, Dept Chem, Seoul 04310, South Korea
[3] Chonbuk Natl Univ, Dept Chem Educ, Jeonju 54896, South Korea
来源
SENSORS | 2016年 / 16卷 / 05期
基金
新加坡国家研究基金会;
关键词
hydrazine; detection; indium tin oxide electrode; dopamine; poly(dopamine) film; cyclic voltammetry; CHEMICAL SENSOR; GOLD NANOPARTICLES; POLYDOPAMINE; OXIDATION; DOPAMINE; FILM; NANOCOMPOSITES; PERFORMANCE; FABRICATION; PORPHYRIN;
D O I
10.3390/s16050647
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a simple and selective method for the electrochemical detection of hydrazine (HZ) using poly(dopamine) (pDA)-modified indium tin oxide (ITO) electrodes. Modification with pDA was easily achieved by submerging the ITO electrode in a DA solution for 30 min. The electrocatalytic oxidation of HZ on the pDA-modified ITO electrode was measured by cyclic voltammetry. In buffer solution, the concentration range for linear HZ detection was 100 mu M-10 mM, and the detection limit was 1 mu M. The proposed method was finally used to determine HZ in tap water to simulate the analysis of real samples. This method showed good recovery (94%-115%) and was not affected by the other species present in the tap water samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Precursor Modified Electrodes: Electrochemical Detection of Captopril
    Lee, Patricia T.
    Compton, Richard G.
    ELECTROANALYSIS, 2015, 27 (10) : 2286 - 2294
  • [32] MODIFIED ELECTRODES FOR ELECTROCHEMICAL DETECTION IN FLOWING STREAMS
    WANG, J
    ANALYTICA CHIMICA ACTA, 1990, 234 (01) : 41 - 48
  • [33] MODIFIED ELECTRODES FOR ELECTROCHEMICAL DETECTION IN FLOWING STREAMS
    WANG, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 43 - ANYL
  • [34] Electrocatalysis and simultaneous detection of dopamine and ascorbic acid using poly(3,4-ethylenedioxy)thiophene film modified electrodes
    Vasantha, V. S.
    Chen, Shen-Ming
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 592 (01) : 77 - 87
  • [35] The Influence of the Cathodic Pretreatment on the Electrochemical Detection of Dopamine by Poly(1-aminoanthracene) Modified Electrode
    Troiani, Estela de Pieri
    Faria, Ronaldo Censi
    ELECTROANALYSIS, 2010, 22 (19) : 2284 - 2289
  • [36] Poly(Methylene Blue) Modified Carbon-based Electrodes for Electrochemical Detection of Hydrogen Sulfide
    Zlamalova, Magda
    Janda, Pavel
    Nesmerak, Karel
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 289 - 293
  • [37] Electrochemical Organophosphorus Pesticide Detection Using Nanostructured Gold-Modified Electrodes
    Chang, Han-Wei
    Chen, Chien-Lin
    Chen, Yan-Hua
    Chang, Yu-Ming
    Liu, Feng-Jiin
    Tsai, Yu-Chen
    SENSORS, 2022, 22 (24)
  • [38] Electrochemical detection of plant virus using gold nanoparticle-modified electrodes
    Khater, Mohga
    de la Escosura-Muniz, Alfredo
    Quesada-Gonzalez, Daniel
    Merkoci, Arben
    ANALYTICA CHIMICA ACTA, 2019, 1046 : 123 - 131
  • [39] Electrochemical Detection of Metals Using Thick Nanofibrous Nafion Web Modified Electrodes
    Musameh, Mustafa M.
    Klink, Daniela
    Choi, Jonghyun
    Yen Bach Truong
    Kyratzis, Ilias Louis
    ELECTROANALYSIS, 2012, 24 (05) : 1207 - 1211
  • [40] Electrochemical Detection of Histamine in Red Wine Using CB[7] Modified Electrodes
    Ngwekazi, Andisiwe
    Arendse, Christopher
    Baker, Priscilla
    CHEMELECTROCHEM, 2025,