Maximization of the sealing effect of fibrin glue in aortic surgery

被引:4
|
作者
Naganuma, Masaaki [1 ]
Akiyama, Masatoshi [1 ]
Takaya, Hiroki [1 ]
Sakuma, Kei [1 ]
Kumagai, Kiichiro [1 ]
Kawamoto, Shunsuke [1 ]
Adachi, Osamu [1 ]
Saiki, Yoshikatsu [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Div Cardiovasc Surg, Aoba Ku, 1-1 Seiryomachi, Sendai, Miyagi 9808574, Japan
关键词
Fibrin glue; Sealant; Aortic surgery; SEALANT;
D O I
10.1007/s11748-019-01155-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Fibrin glue is used to reinforce anastomosis in aortic surgery. There has not yet been a consensus on how it should be applied optimally. This study aimed to define the optimal condition of applying fibrin glue. Methods In experiment 1, we determined the optimal condition for spraying fibrin glue using an expanded polytetrafluoroethylene graft within a needle hole. The length and area of the fibrin cap within the hole were measured. In experiment 2, methods for applying fibrinogen were assessed by comparing brushing and spraying. In experiment 3, swine aorta segments sutured with a Dacron graft were divided into the following three groups: nothing was applied; fibrinogen was sprayed and rubbed using brush. The aorta was clamped and blood was infused from an occlusion catheter inserted into the graft. The pressure at the first appearance of blood leak was recorded. Results In experiment 1, among the four groups divided by the pressure and distance of spraying, the fibrin cap area in the group with 0.075 MPa and 2-cm spray distance was significantly larger than that in the group with 0.15 MPa and 2 cm (P < 0.01). In experiment 2, the fibrin cap area in the brushing group was significantly larger than that in the spraying group (P < 0.05). In experiment 3, the capacity to resist endoluminal pressure was higher in the brushing and combined spraying group compared with that in the sequential combined spraying group (P < 0.01). Conclusions The brush and spray methods showed excellent hemostatic outcomes.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 50 条
  • [21] Fibrin glue as agent for sealing corneal and conjunctival wound leaks
    C Scalcione
    D Ortiz-Vaquerizas
    D G Said
    H S Dua
    Eye, 2018, 32 : 463 - 466
  • [22] THE USE OF FIBRIN GLUE IN UROLOGICAL SURGERY
    ALBALA, D
    MCKAY, T
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1463 - 1463
  • [23] Fibrin glue as agent for sealing corneal and conjunctival wound leaks
    Scalcione, C.
    Ortiz-Vaquerizas, D.
    Said, D. G.
    Dua, H. S.
    EYE, 2018, 32 (02) : 463 - 466
  • [24] Sealing of gastrointestinal anastomoses with fibrin glue coated collagen patch
    Nordentoft, Tyge
    DANISH MEDICAL JOURNAL, 2015, 62 (05):
  • [25] Sealing of polyester prostheses with autologous fibrin glue and bone marrow
    Cardon, A
    Chakfé, N
    Thaveau, F
    Gagnon, E
    Hartung, O
    Aillet, S
    Kerdiles, Y
    Dion, YM
    Kretz, JG
    Doillon, CJ
    ANNALS OF VASCULAR SURGERY, 2000, 14 (06) : 543 - 552
  • [26] THE USE OF FIBRIN GLUE IN HEPATIC SURGERY
    Wang Jie
    Ou Jinjia
    Chen Jisheng(Department of General Surgery
    Chinese Journal of Biomedical Engineering(English Edition), 1997, (03) : 210 - 211
  • [27] EXPERIENCES WITH FIBRIN GLUE IN EAR SURGERY
    STRAATMAN, NJA
    SIBINGA, CTS
    CLINICAL OTOLARYNGOLOGY, 1983, 8 (01): : 69 - 69
  • [28] PREPARATION AND USE OF FIBRIN GLUE IN SURGERY
    SILVER, FH
    WANG, MC
    PINS, GD
    BIOMATERIALS, 1995, 16 (12) : 891 - 903
  • [29] The use of fibrin glue in surgery of the knee
    Patel, S.
    Rodriguez-Merchan, E. C.
    Haddad, F. S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (10): : 1325 - 1331
  • [30] Use of fibrin glue in maxillofacial surgery
    Davis, BR
    Sandor, GKB
    JOURNAL OF OTOLARYNGOLOGY, 1998, 27 (02): : 107 - 112