Percutaneous closure of ascending aortic pseudoaneurysm using Amplatzer septal occluder device: The first clinical case report and literature review

被引:39
作者
Bashir, F [1 ]
Quaife, R [1 ]
Carroll, JD [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Div Cardiol, Denver, CO 80262 USA
关键词
aortic pseudoaneurysm; transthoracic echocardiogram; Amplatzer septal occluder;
D O I
10.1002/ccd.20422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the first case of the use of an Amplatzer septal occluder device to close a large ascending aortic pseudoaneurysm. The patient had a complex cardiac history with redo coronary artery bypass graft surgery, severe left ventricular dysfunction, and end-stage renal disease requiring hemodialysis. The procedure was successfully performed under fluoroscopic and 2D/3D transthoracic echocardiographic guidance. Six-week follow-up with both transthoracic echocardiography and MRI showed the device was in proper position with complete closure of the pseudoaneurysm. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:547 / 551
页数:5
相关论文
共 14 条
  • [1] Abreo G, 1997, AM J MED SCI, V314, P273
  • [2] Transluminal occlusion of a pseudoaneurysm arising from a thoracic aortic graft patch using catheter delivery of thrombin
    Badran, MF
    Gould, DA
    Sampson, C
    Harris, PL
    Hewitt, H
    Stables, R
    Rashid, A
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (09) : 1201 - 1205
  • [3] Management of pseudoaneurysm of the ascending aorta performed under circulatory arrest by port-access
    D'Attellis, N
    Diemont, FF
    Julia, PL
    Cardon, C
    Fabiani, JN
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03) : 1010 - 1011
  • [4] de Almeida R M, 2001, Arq Bras Cardiol, V76, P326
  • [5] Aortic pseudoaneurysm complicating sternal wound infection following CABG
    Devbhandari, MP
    Balasubramanian, SK
    Campanella, C
    Brackenbury, ET
    [J]. CARDIOVASCULAR SURGERY, 2003, 11 (03): : 243 - 245
  • [6] Transcatheter closure of fistula between the right pulmonary artery and left atrium using the Amplatzer duct occluder
    Francis, E
    Sivakumar, K
    Kumar, RK
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (01) : 83 - 86
  • [7] Device closure of iatrogenic membranous ventricular septal defects after prosthetic aortic valve replacement using the amplatzer membranous ventricular septal defect occluder
    Holzer, R
    Latson, L
    Hijazi, ZM
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (02) : 276 - 280
  • [8] Neonatal transcatheter occlusion of a large coronary artery fistula with amplatzer duct occluder
    Khan, MD
    Oureshi, SA
    Rosenthal, E
    Sharland, GK
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (02) : 282 - 286
  • [9] Novel use of the amplatzer duct occluder to close perivalvar leak involving a prosthetic mitral valve
    Kort, HW
    Sharkey, AM
    Balzer, DT
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (04) : 548 - 551
  • [10] Transcatheter left atrial appendage occlusion with Amplatzer devices to obviate anticoagulation in patients with atrial fibrillation
    Meier, B
    Palacios, I
    Windecker, S
    Rotter, M
    Cao, QL
    Keane, D
    Ruiz, CE
    Hijazi, ZM
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (03) : 417 - 422