Ion-optical scheme for a portable high-sensitivity mass spectrograph

被引:4
|
作者
Kogan, VT [1 ]
Manninen, SA [1 ]
Lebedev, DS [1 ]
Viktorova, OS [1 ]
Amanbaev, IT [1 ]
机构
[1] Russian Acad Sci, AF Ioffe Physicotech Inst, St Petersburg 195021, Russia
关键词
D O I
10.1134/1.1947360
中图分类号
O59 [应用物理学];
学科分类号
摘要
An ion-optical scheme that allows for a considerable improvement of the sensitivity and speed of a mass spectrograph is suggested. These ends are accomplished by appropriately choosing the parameters of an electrostatic capacitor and the shape and location of a magnetic lens, as well as by using an original multichannel linear sectional detector. The numerical simulation of the detector is carried out. It is shown that rapid analysis of multicomponent mixtures in a wide mass range, along with a substantial extension of the dynamic range of a signal recorded, is a possibility. The basic parameters of a mass analyzer based on the scheme suggested are verified experimentally, and the results obtained are discussed. (c) 2005 Pleiades Publishing, Inc.
引用
收藏
页码:794 / 798
页数:5
相关论文
共 50 条
  • [21] STUDY OF THE ION-OPTICAL PROPERTIES OF THE MASS-SPECTROMETER LIDIA
    BOGDANOV, DD
    RODIN, AM
    SIDORCHUK, SI
    STEPANTSOV, SV
    TERAKOPIAN, GM
    TIMAKOV, VA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (1-2): : 205 - 212
  • [22] Ion-optical system with energy filtering for a monopole mass spectrometer
    L. P. Ovsyannikova
    T. Ya. Fishkova
    V. A. Surkov
    Technical Physics, 2007, 52 : 1614 - 1617
  • [23] ION-OPTICAL SYSTEM FOR SHAPING ION-BEAMS WITH HIGH CURRENT
    GRISHIN, SD
    KUZOVLEV, VF
    ORLOV, RV
    OGORODNI.SN
    ZHURNAL TEKHNICHESKOI FIZIKI, 1974, 44 (11): : 2374 - 2377
  • [24] PORTABLE, HIGH-SENSITIVITY RADIATION DETECTOR FOR SEARCH APPLICATIONS
    HENRY, CN
    CHAMBERS, WH
    WORTH, GM
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 114 - 114
  • [25] Portable biometric system of high-sensitivity absorption detection
    Chen, Der-Chin
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2008, 50 (04) : 868 - 871
  • [26] HIGH-SENSITIVITY MASS-SPECTROSCOPY
    REYNOLDS, JH
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1984, (71): : 345 - 346
  • [27] NEW METHODS FOR CONSIDERING AND CALCULATING THE ION-OPTICAL ACTION OF MASS SPECTROMETERS
    TARANTIN, NI
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 46 (JAN): : 51 - 54
  • [28] ION-OPTICAL SOLUTIONS IN TIME-OF-FLIGHT MASS-SPECTROMETRY
    IOANOVICIU, D
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (11) : 985 - 997
  • [29] ION DETECTOR BASED ON MICROCHANNEL PLATES FOR HIGH-SENSITIVITY MASS-SPECTROMETER
    RODIN, AM
    SIDORCHUK, SI
    TIMAKOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (02) : 317 - 319
  • [30] High-sensitivity and field analysis of lead by portable optical emission spectrometry using a microplasma trap
    Zhang, Yaru
    Liu, Jixin
    Mao, Xuefei
    Na, Xing
    Tian, Di
    Qian, Yongzhong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1141 - 1149