Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)

被引:7
作者
Fakhrabad, Azam Hosseini [1 ]
Khoshnood, Razieh Sanavi [1 ]
Ebrahimi, Mahmoud [1 ]
Abedi, Mohammad Reza [2 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
关键词
ion selective electrode; multi-walled carbon nanotubes; D-optimal optimization; potentiometry; NANOPOROUS SILICA-GEL; SENSOR; OXIDATION; BROMIDE;
D O I
10.1134/S1061934820070072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, different electrodes were made by combining certain percentages of carbon paste for a range of cations. Then, ligand selectivity was calculated for each cation using a potentiometric method to identify the most sensitive cation. A modified carbon paste electrode was applied to the quantification of chromium cation based on carbon nanotubes. In addition, paraffin, graphite, and 1,13-bis(8-quinolyl)-l,4,7,10,13-pentaoxatridecane were utilized in the manufacture of the electrodes. To get an optimum composition, D-optimal test design method was employed to increase electrode sensitivity and placement accuracy. Upon combining optimal percentages, this electrode showed the Nernstian response within the concentration range of 1.0 x 10(-10)-1.0 x 10(-2)M, slope of 19.63 mV/decade with a detection limit of 3 x 10(-11)M. The potential was found to remain constant within the pH range of 5.0-9.0, while a gradual deviation was observed outside this range.
引用
收藏
页码:951 / 957
页数:7
相关论文
共 38 条
[1]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[2]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P4158
[3]   Potentiometric determination of iron in polluted water samples using new modified Fe(III)-screen printed ion selective electrode [J].
Ali, Tamer Awad ;
Farag, Ahmed A. ;
Mohamed, Gehad G. .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (04) :2394-2400
[4]  
Brereton R.G., 2003, DATA ANAL LAB CHEM P, DOI DOI 10.1002/0470863242
[5]   Mechanism of hexavalent chromium detoxification by microorganisms and bioremediation application potential: A review [J].
Cheung, K. H. ;
Gu, Ji-Dong .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2007, 59 (01) :8-15
[6]  
Emmanuel S.D., 2014, J TOXICOLOGY ENV HLT, V6, P89, DOI [10.5897/JTEHS2013.0293, DOI 10.5897/JTEHS2013.0293]
[7]  
Eriksson L., 2008, Design of Experiments-Principles and Applications
[8]  
Esbensen KH., 2002, Introduction to Multivariate Data Analysis - Overview Multivariate data analysis: in practice: a introduction to multivariate data analysis and experimental design
[9]   Heavy metal distribution in sediments and ecological risk assessment: The role of diagenetic processes in reducing metal toxicity in bottom sediments [J].
Fernandes, HM .
ENVIRONMENTAL POLLUTION, 1997, 97 (03) :317-325