Fractures of the coronoid: morphology based upon computer tomography scanning

被引:39
作者
Adams, Julie E. [1 ]
Sanchez-Sotelo, Joaquin [2 ]
Kallina, Charles F. [3 ]
Morrey, Bernard F. [2 ]
Steinmann, Scott P. [2 ]
机构
[1] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55454 USA
[2] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
[3] Scott & White Healthcare Orthopaed, Temple, TX USA
关键词
Coronoid; coronoid fracture; coronoid process; classification system; elbow; elbow trauma; elbow fracture; PROXIMAL HUMERAL FRACTURES; ANTEROMEDIAL FACET; INTEROBSERVER RELIABILITY; OBSERVER AGREEMENT; ELBOW STABILITY; RADIAL HEAD; CLASSIFICATION; ULNA; INJURY; REPRODUCIBILITY;
D O I
10.1016/j.jse.2012.01.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis/Background: Coronoid fractures have traditionally been described by the Regan-Morrey classification system, based upon lateral plain film radiographs. However, use of computer tomography (CT) scans to determine fracture morphology, define associated injuries, and make treatment plans is now commonplace. In addition, it is increasingly recognized that classification systems based upon plain film imaging studies may not be adequate to describe complex fracture patterns. The purpose of the present investigation was to review CT scans obtained for elbow trauma to describe coronoid fracture morphology and determine inter-and intra-observer reliability. Methods: CT scans performed for elbow trauma over a 2-year period were examined to identify coronoid fractures, and recurring patterns were sought. After patterns were identified, the scans were reviewed by 3 observers to determine inter-and intra-observer reliability. Results: Of 373 CT scans, 52 identified coronoid fractures were appropriate for review. Five common patterns were identified, including a tip type, mid-transverse type, basal type, anteromedial oblique fractures, and an anterolateral oblique type fracture that has not been well described previously. Inter-and intra-observer reliability ranged from good to very good in this series. Discussion/Conclusion: In this series, we describe anatomic patterns by which coronoid fractures break. Five common patterns were noted: a "tip'' type fracture seen in 29% of the cases; a "mid-transverse'' type fracture (24%); a "basal'' type fracture (23); and 2 "oblique'' type fracture patterns (24%), including an "anteromedial'' type fracture (17%) and an "anterolateral'' type (7%). There was a high rate of intra-and inter-observer reliability between and within 3 observers.
引用
收藏
页码:782 / 788
页数:7
相关论文
共 37 条
[1]   Ulnar coronoid process anatomy - Possible implications for elbow instability [J].
Ablove, Robert H. ;
Moy, Owen J. ;
Howard, Craig ;
Peimer, Clayton A. ;
S'Doia, Samuel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (449) :259-261
[2]  
Adams JE, 2009, J BONE JOINT SURG BR, V91B, P632, DOI [10.1302/0301-620X.91B5.21755, 10.1302/0301-620X.91B5]
[3]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[4]   Expanded Use Of Imaging Technology And The Challenge of Measuring Value [J].
Baker, Laurence C. ;
Atlas, Scott W. ;
Afendulis, Christopher C. .
HEALTH AFFAIRS, 2008, 27 (06) :1467-1478
[5]   Reliability of a modified Gartland classification of supracondylar humerus fractures [J].
Barton, KL ;
Kaminsky, CK ;
Green, DW ;
Shean, CJ ;
Kautz, SM ;
Skaggs, DL .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2001, 21 (01) :27-30
[6]   The effect of coronoid fractures on elbow kinematics and stability [J].
Beingessner, Daphne M. ;
Dunning, Cynthia E. ;
Stacpoole, Rebecca A. ;
Johnson, James A. ;
King, Graham J. W. .
CLINICAL BIOMECHANICS, 2007, 22 (02) :183-190
[7]   Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[8]   The radiologist's conundrum: benefits and costs of increasing CT capacity and utilization - Opinion [J].
Boland, Giles W. L. ;
Guimaraes, Alexander S. ;
Mueller, Peter R. .
EUROPEAN RADIOLOGY, 2009, 19 (01) :9-11
[9]   Isolated anterolateral fracture of the coronoid process of the ulna: a case report [J].
Butler, Daniel P. ;
Alsousou, Joseph ;
Keys, Richard .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (02) :E1-E4
[10]  
Chemama B, 2010, ORTHOP TRAUMATOL-SUR, V96, P147, DOI [10.1016/j.rcot.2010.02.008, 10.1016/j.otsr.2009.11.009]