Sequence-specific DNA solid-phase extraction in an on-chip monolith: Towards detection of antibiotic resistance genes

被引:9
作者
Knob, Radim [1 ]
Nelson, Daniel B. [2 ]
Robison, Richard A. [2 ]
Woolley, Adam T. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Microbiol & Mol Biol, Provo, UT 84602 USA
基金
美国国家卫生研究院;
关键词
Hybridization; Microfluidics; Monolith; Sepsis; HYBRIDIZATION; CHROMATOGRAPHY; PERFORMANCE; PROTEIN; BLOOD; IDENTIFICATION; PURIFICATION; DIAGNOSTICS; MONOVALENT; SEPARATION;
D O I
10.1016/j.chroma.2017.07.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Antibiotic resistance of bacteria is a growing problem and presents a challenge for prompt treatment in patients with sepsis. Currently used methods rely on culturing or amplification; however, these steps are either time consuming or suffer from interference issues. A microfluidic device was made from black polypropylene, with a monolithic column modified with a capture oligonucleotide for sequence selective solid-phase extraction of a complementary target from a lysate sample. Porous properties of the monolith allow flow and hybridization of a target complementary to the probe immobilized on the column surface. Good flow-through properties enable extraction of a 100 mu L sample and elution of target DNA in 12 min total time. Using a fluorescently labeled target oligonucleotide related to Verona Integron-Mediated Metallo-beta-lactamase it was possible to extract and detect a 1 pM sample with 83% recovery. Temperature-mediated elution by heating above the duplex melting point provides a clean extract without any agents that interfere with base pairing, allowing various labeling methods or further downstream processing of the eluent. Further integration of this extraction module with a system for isolation and lysis of bacteria from blood, as well as combining with single-molecule detection should allow rapid determination of antibiotic resistance. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 39 条
[11]   Improved DNA extraction efficiency from low level cell numbers using a silica monolith based micro fluidic device [J].
Kashkary, Loay ;
Kemp, Cordula ;
Shaw, Kirsty J. ;
Greenway, Gillian M. ;
Haswell, Stephen J. .
ANALYTICA CHIMICA ACTA, 2012, 750 :127-131
[12]   A chitosan coated monolith for nucleic acid capture in a thermoplastic microfluidic chip [J].
Kendall, Eric L. ;
Wienhold, Erik ;
DeVoe, Don L. .
BIOMICROFLUIDICS, 2014, 8 (04)
[13]   Advances in monoliths and related porous materials for microfluidics [J].
Knob, Radim ;
Sahore, Vishal ;
Sonker, Mukul ;
Woolley, Adam T. .
BIOMICROFLUIDICS, 2016, 10 (03)
[14]   Modeling of flow in a polymeric chromatographic monolith [J].
Koku, Harun ;
Maier, Robert S. ;
Czymmek, Kirk J. ;
Schure, Mark R. ;
Lenhoff, Abraham M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (22) :3466-3475
[15]   New "one-step" method for the simultaneous synthesis and anchoring of organic monolith inside COC microchip channels [J].
Ladner, Yoann ;
Bruchet, Anthony ;
Cretier, Gerard ;
Dugas, Vincent ;
Randon, Jerome ;
Faure, Karine .
LAB ON A CHIP, 2012, 12 (09) :1680-1685
[16]   Affinity chromatography of DNA on nonporous copolymerized particles of styrene and glycidyl methacrylate with immobilized polynucleotide [J].
Lee, GY ;
Chen, CH ;
Wang, TH ;
Lee, WC .
ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) :235-241
[17]   Physicochemical perspectives on DNA microarray and biosensor technologies [J].
Levicky, R ;
Horgan, A .
TRENDS IN BIOTECHNOLOGY, 2005, 23 (03) :143-149
[18]   Biocompatible polymeric monoliths for protein and peptide separations [J].
Li, Yun ;
Lee, Milton L. .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (20) :3369-3378
[19]   Cell lysis and DNA extraction of gram-positive and gram-negative bacteria from whole blood in a disposable microfluidic chip [J].
Mahalanabis, Madhumita ;
Al-Muayad, Hussam ;
Kulinski, M. Dominika ;
Altman, Dave ;
Klapperich, Catherine M. .
LAB ON A CHIP, 2009, 9 (19) :2811-2817
[20]   High-performance affinity monolith chromatography: Development and evaluation of human serum albumin columns [J].
Mallik, R ;
Tao, J ;
Hage, DS .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7013-7022