Accuracy of alveolar bone measurements from cone beam computed tomography acquired using varying settings

被引:43
作者
Cook, V. C.
Timock, A. M.
Crowe, J. J. [1 ]
Wang, M. [2 ]
Covell, D. A., Jr. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Sch Dent, Dept Orthodont, Portland, OR 97201 USA
[2] Providence Hlth & Serv, Portland, OR USA
关键词
alveolar bone height; cone beam computed tomography; orthodontics; reliability of results; BUCCAL BONE; MAXILLOFACIAL RADIOLOGY; ANTHROPOMETRIC ANALYSIS; DIAGNOSTIC-ACCURACY; DENTAL IMPLANTS; CORTICAL BONE; RELIABILITY; THICKNESS; HEIGHT; VOLUME;
D O I
10.1111/ocr.12072
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Structured Abstract ObjectivesTo investigate the accuracy and reliability of cone beam computed tomography (CBCT) measurements of buccal alveolar bone height (BBH) and thickness (BBT) using custom acquisition settings. Settings and Sample PopulationSchool of Dentistry, Oregon Health & Science University. Twelve embalmed cadavers. Materials and MethodsCadaver heads were imaged by CBCT (i-CAT((R)) 17-19, Imaging Sciences International, Hatfield, PA) using a long scan' (LS) setting with 619 projection images, 360 degrees revolution, 26.9s duration, and 0.2mm voxel size, and using a short scan' (SS) setting with 169 projection images, 180 degrees rotation, 4.8s duration, and 0.3mm voxel size. BBH and BBT were measured with 65 teeth, indirectly from CBCT images and directly through dissection. Comparisons were assessed using paired t-tests (p0.05). Level of agreement was assessed by concordance correlation coefficients, Pearson's correlation coefficients, and Bland-Altman plots. ResultsMean differences in measurements compared to direct measurements were as follows, LS 0.170.12 (BBH) and 0.10 +/- 0.07mm (BBT), and SS 0.41 +/- 0.32 (BBH) and 0.12 +/- 0.11mm (BBT). No statistical differences were found with any of BBH or BBT measurements. Correlation coefficients and Bland-Altman plots showed agreement was high between direct and indirect measurement methods, although agreement was stronger for measurements of BBH than BBT. ConclusionsCompared to the LS, the similarity in results with the reduced scan times and hence reduced effective radiation dose, favors use of shorter scans, unless other purposes for higher resolution imaging can be defined.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 40 条
[31]   Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography [J].
Razavi, Touraj ;
Palmer, Richard M. ;
Davies, Jonathan ;
Wilson, Ron ;
Palmer, Paul J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (07) :718-725
[32]   Digital tooth-based superimposition method for assessment of alveolar bone levels on cone-beam computed tomography images [J].
Romero-Delmastro, Alejandro ;
Kadioglu, Onur ;
Currier, G. Frans ;
Cook, Tanner .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (02) :255-263
[33]  
Scarfe WC, 2006, J CAN DENT ASSOC, V72, P75
[34]   Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs [J].
Sherrard, John F. ;
Rossouw, P. Emile ;
Benson, Byron W. ;
Carrillo, Roberto ;
Buschang, Peter H. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) :S100-S108
[35]   Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography [J].
Shiratori, Lucy Naomi ;
Marotti, Juliana ;
Yamanouchi, Julio ;
Chilvarquer, Israel ;
Contin, Ivo ;
Tortamano-Neto, Pedro .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) :797-804
[36]   Comparison of cone beam computed tomography imaging with physical measures [J].
Stratemann, S. A. ;
Huang, J. C. ;
Maki, K. ;
Miller, A. J. ;
Hatcher, D. C. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (02) :80-93
[37]   Effect of bone thickness on alveolar bone-height measurements from cone-beam computed tomography images [J].
Sun, Zongyang ;
Smith, Tharon ;
Kortam, Sahira ;
Kim, Do-Gyoon ;
Tee, Boon Ching ;
Fieldse, Henry .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (02) :e117-e127
[38]   Anthropometric Analysis of the Human Mandibular Cortical Bone as Assessed by Cone-Beam Computed Tomography [J].
Swasty, Denise ;
Lee, Janice S. ;
Huang, John C. ;
Maki, Koutaro ;
Gansky, Stuart A. ;
Hatcher, David ;
Miller, Arthur J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (03) :491-500
[39]   Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging [J].
Timock, Adam M. ;
Cook, Valane ;
McDonald, Terry ;
Leo, Michael C. ;
Crowe, Jennifer ;
Benninger, Brion L. ;
Covell, David A., Jr. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) :734-744
[40]  
Tomasi C, 2011, DENTOMAXILLOFAC RAD, V40, P244, DOI [10.1259/dmfr/17432330, 10.1259/dmfr/1742330]