Accuracy of alveolar bone measurements from cone beam computed tomography acquired using varying settings

被引:43
作者
Cook, V. C.
Timock, A. M.
Crowe, J. J. [1 ]
Wang, M. [2 ]
Covell, D. A., Jr. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Sch Dent, Dept Orthodont, Portland, OR 97201 USA
[2] Providence Hlth & Serv, Portland, OR USA
关键词
alveolar bone height; cone beam computed tomography; orthodontics; reliability of results; BUCCAL BONE; MAXILLOFACIAL RADIOLOGY; ANTHROPOMETRIC ANALYSIS; DIAGNOSTIC-ACCURACY; DENTAL IMPLANTS; CORTICAL BONE; RELIABILITY; THICKNESS; HEIGHT; VOLUME;
D O I
10.1111/ocr.12072
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Structured Abstract ObjectivesTo investigate the accuracy and reliability of cone beam computed tomography (CBCT) measurements of buccal alveolar bone height (BBH) and thickness (BBT) using custom acquisition settings. Settings and Sample PopulationSchool of Dentistry, Oregon Health & Science University. Twelve embalmed cadavers. Materials and MethodsCadaver heads were imaged by CBCT (i-CAT((R)) 17-19, Imaging Sciences International, Hatfield, PA) using a long scan' (LS) setting with 619 projection images, 360 degrees revolution, 26.9s duration, and 0.2mm voxel size, and using a short scan' (SS) setting with 169 projection images, 180 degrees rotation, 4.8s duration, and 0.3mm voxel size. BBH and BBT were measured with 65 teeth, indirectly from CBCT images and directly through dissection. Comparisons were assessed using paired t-tests (p0.05). Level of agreement was assessed by concordance correlation coefficients, Pearson's correlation coefficients, and Bland-Altman plots. ResultsMean differences in measurements compared to direct measurements were as follows, LS 0.170.12 (BBH) and 0.10 +/- 0.07mm (BBT), and SS 0.41 +/- 0.32 (BBH) and 0.12 +/- 0.11mm (BBT). No statistical differences were found with any of BBH or BBT measurements. Correlation coefficients and Bland-Altman plots showed agreement was high between direct and indirect measurement methods, although agreement was stronger for measurements of BBH than BBT. ConclusionsCompared to the LS, the similarity in results with the reduced scan times and hence reduced effective radiation dose, favors use of shorter scans, unless other purposes for higher resolution imaging can be defined.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 40 条
[1]   A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion [J].
Akyalcin, Sercan ;
Schaefer, Jeffrey S. ;
English, Jeryl D. ;
Stephens, Claude R. ;
Winkelmann, Sam .
IMAGING SCIENCE IN DENTISTRY, 2013, 43 (02) :85-90
[2]   A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions [J].
Al-Ekrish, A. A. ;
Ekram, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) :67-75
[3]   Comparison of 6 cone-beam computed tomography systems for image quality and detection of simulated canine impaction-induced external root resorption in maxillary lateral incisors [J].
Alqerban, Ali ;
Jacobs, Reinhilde ;
Fieuws, Steffen ;
Nackaerts, Olivia ;
Willems, Guy .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :E129-E139
[4]   Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine [J].
Ballrick, John W. ;
Palomo, J. Martin ;
Ruch, Edward ;
Amberman, B. Douglas ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) :573-582
[5]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[6]   Linear Accuracy of Cone Beam CT Derived 3D Images [J].
Brown, April A. ;
Scarfe, William C. ;
Scheetz, James P. ;
Silveira, Anibal M. ;
Farman, Allan G. .
ANGLE ORTHODONTIST, 2009, 79 (01) :150-157
[7]   Three-dimensional assessment of buccal alveolar bone after rapid and slow maxillary expansion: A clinical trial study [J].
Brunetto, Mauricio ;
Pereira Andriani, Juliana da Silva ;
Ulema Ribeiro, Gerson Luiz ;
Locks, Arno ;
Correa, Marcio ;
Correa, Leticia Ruhland .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (05) :633-644
[8]  
CARRANZA FA, 2002, TOOTH SUPPORTING STR
[9]   American Academy of Oral and Maxillofacial Radiology executive opinion statement on performing and interpreting diagnostic cone beam computed tomography [J].
Carter, Laurie ;
Geist, James ;
Scarfe, William C. ;
Angelopoulos, Christos ;
Nair, Madhu K. ;
Odont, Lic ;
Hildebolt, Charles F. ;
Tyndall, Donald ;
Shrout, Michael .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (04) :561-562
[10]   Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption [J].
Durack, C. ;
Patel, S. ;
Davies, J. ;
Wilson, R. ;
Mannocci, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) :136-147