Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

被引:45
作者
Lee, Ho [1 ]
Xing, Lei [1 ]
Lee, Rena [2 ]
Fahimian, Benjamin P. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Ewha Womans Univ, Sch Med, Dept Radiat Oncol, Seoul 158710, South Korea
基金
美国国家科学基金会;
关键词
cone-beam CT; half beam blocker; scatter correction; FDK; total variation; GUIDED RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; RECONSTRUCTION; ALGORITHM;
D O I
10.1118/1.3691901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3691901]
引用
收藏
页码:2386 / 2395
页数:10
相关论文
共 22 条
[1]   AN ANALYTICAL MODEL OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :721-725
[2]   Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy [J].
Brunner, Stephen ;
Nett, Brian E. ;
Tolakanahalli, Ranjini ;
Chen, Guang-Hong .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) :1015-1030
[3]   Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography [J].
Fahimian, Benjamin P. ;
Mao, Yu ;
Cloetens, Peter ;
Miao, Jianwei .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5383-5400
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[6]   Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT) [J].
Jin, Jian-Yue ;
Ren, Lei ;
Liu, Qiang ;
Kim, Jinkoo ;
Wen, Ning ;
Guan, Huaiqun ;
Movsas, Benjamin ;
Chetty, Indrin J. .
MEDICAL PHYSICS, 2010, 37 (11) :5634-5644
[7]   Fast hybrid CPU- and GPU-based CT reconstruction algorithm using air skipping technique [J].
Lee, Byeonghun ;
Lee, Ho ;
Shin, Yeong Gil .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (03) :221-234
[8]   Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series [J].
Lee, Ho ;
Lee, Jeongjin ;
Shin, Yeong Gil ;
Lee, Rena ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12) :3417-3440
[9]   Image metamorphosis with scattered feature constraints [J].
Lee, S ;
Wolberg, G ;
Chwa, KY ;
Shin, SY .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 1996, 2 (04) :337-354
[10]   Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging [J].
Li, Heng ;
Mohan, Radhe ;
Zhu, X. Ronald .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23) :6729-6748