Cloud point extraction for the determination of As(111) in water samples by electrothermal atomic absorption spectrometry

被引:60
作者
Tang, AN [1 ]
Ding, GS
Yan, XP
机构
[1] Nankai Univ, State Key Lab Funct Polymer Mat Adsorpt & Separat, Coll Chem, Tianjin 300071, Peoples R China
[2] Nankai Univ, Res Ctr Analyt Sci, Coll Chem, Tianjin 300071, Peoples R China
[3] Tianjin Univ, Coll Pharmaceut & Biotechnol, Tianjin 300072, Peoples R China
关键词
cloud point extraction; preconcentration and complexation; electrothermal atomic absorption spectrometry; arsenite;
D O I
10.1016/j.talanta.2005.04.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cloud point extraction was applied as a preconcentration step for electrothermal atomic absorption spectrometry (ETAAS) determination of As(III) in aqueous solutions. After complexation with ammonium pyrrolidinedithiocarbamate, the analyte was quantitatively extracted to the surfactant-rich phase in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X- 114) after centrifugation. 0.1 moL L-1 HNO3 in methanol was added to the surfactant-rich phase before ETAAS determination. The precision (R.S.D.) for 11 replicate determinations of 5.0 mu g L-1 of As(III) was 3.0%. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for ETAAS determination and in the initial solution, was 36 for As(III). The linear concentration range was from 0.1 to 20 mu g L-1. The developed method was applied to the determination of As(III) in lake water and river water. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:942 / 946
页数:5
相关论文
共 39 条
[31]   Quantification of polycyclic aromatic hydrocarbons and polychlorinated dibenzo-p-dioxins in human serum by combined micelle mediated extraction (cloud-point extraction) and HPLC [J].
Sirimanne, SR ;
Barr, JR ;
Patterson, DG ;
Ma, L .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1556-1560
[32]   DIFFERENTIAL DETERMINATION OF ARSENIC(III) AND TOTAL ARSENIC USING FLOW-INJECTION ONLINE SEPARATION AND PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
SPERLING, M ;
YIN, XF ;
WELZ, B .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (14) :1789-1801
[33]   Micelle-mediated extraction as a tool for separation and preconcentration in metal analysis [J].
Stalikas, CD .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (05) :343-355
[34]   Cloud point extraction for high-performance liquid chromatographic speciation of Cr(III) and Cr(VI) in aqueous solutions [J].
Tang, AN ;
Jiang, DQ ;
Jiang, Y ;
Wang, SW ;
Yan, XP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (02) :183-188
[35]   Cloud point extraction preconcentration for capillary electrophoresis of metal ions [J].
Tang, AN ;
Jiang, DQ ;
Yan, XP .
ANALYTICA CHIMICA ACTA, 2004, 507 (02) :199-204
[36]   Comparison of ultrasound-assisted extraction, microwave-assisted acid leaching and reflux for the determination of arsenic, cadmium and copper in contaminated soil samples by electrothermal atomic absorption spectrometry [J].
Väisänen, A ;
Suontamo, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :739-742
[37]   Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (Ultra)trace amounts of Arsenic(III) and Arsenic(V) in natural water samples [J].
Yan, XP ;
Yin, XB ;
He, XW ;
Jiang, Y .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2162-2166
[38]   On-line coupling of capillary electrophoresis to hydride generation atomic fluorescence spectrometry for arsenic speciation analysis [J].
Yin, XB ;
Yan, XP ;
Jiang, Y ;
He, XW .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3720-3725
[39]  
[No title captured]