Experiences with packed capillary electrochromatography at ambient pressure

被引:104
|
作者
vandenBosch, SE [1 ]
Heemstra, S [1 ]
Kraak, JC [1 ]
Poppe, H [1 ]
机构
[1] UNIV AMSTERDAM,ANALYT CHEM LAB,AMSTERDAM INST MOL STUDIES,NL-1018 WV AMSTERDAM,NETHERLANDS
关键词
air bubbles; electrochromatography; capillary columns; packed capillary columns; packing retainers; frits; phenols; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(96)00612-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The practical execution of packed capillary electrochromatography is evaluated. The most serious problem is the generation of air bubbles in the system. This occurs especially in frits which were fabricated by glueing particles differing from the packing particles. No air bubbles were generated with frits which were prepared by locally sintering a narrow band of the reversed-phase packing by means of a heating filament, while flushing the column with water. In this way electrochromatography can be performed simply without pressurizing the buffer vials, providing the mobile phase is frequently degassed with helium. The performance under electrically driven conditions appears to be excellent and for 5 mu m reversed-phase particles reduced plate heights down to 1.8 were achieved. Compared to pressure driven conditions, 25-40% smaller plate heights were obtained under electrically driven conditions.
引用
收藏
页码:165 / 177
页数:13
相关论文
共 50 条
  • [1] Capillary electrochromatography in columns packed by centripetal forces
    Fermier, AM
    Colon, LA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (05) : 439 - 447
  • [2] Attempt to define the role of the length of the packed section in capillary electrochromatography
    Cikalo, MG
    Bartle, KD
    Myers, P
    JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) : 25 - 34
  • [3] Aspects of column fabrication for packed capillary electrochromatography
    Angus, PDA
    Demarest, CW
    Catalano, T
    Stobaugh, JF
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 347 - 365
  • [4] Magnetically immobilized frits for the preparation of packed columns used in capillary electrochromatography
    Wang, Hongling
    Cao, Jingjing
    Bi, Yanping
    Chen, Lei
    Wan, Qian-Hong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (31) : 5882 - 5887
  • [5] Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries
    Choudhary, G
    Horvath, C
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 161 - 183
  • [6] Photopolymerized sol-gel frits for packed columns in capillary electrochromatography
    Kato, M
    Dulay, MT
    Bennett, BD
    Quirino, JP
    Zare, RN
    JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) : 187 - 195
  • [7] Kinetic performance evaluation and perspectives of contemporary packed column capillary electrochromatography
    De Smet, Seppe
    Lynen, Frederic
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1355 : 261 - 268
  • [8] Separation of enantiomers by packed capillary electrochromatography on a cellulose-based stationary phase
    Mayer, S
    Briand, X
    Francotte, E
    JOURNAL OF CHROMATOGRAPHY A, 2000, 875 (1-2) : 331 - 339
  • [9] Capillary electrochromatography with macroporous particles
    Stol, R
    Kok, WT
    Poppe, H
    JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) : 45 - 54
  • [10] Simplification of capillary electrochromatography procedures