Verification of false-positive blood culture results generated by the BACTEC 9000 series by eubacterial 16S rDNA and panfungal 18S rDNA directed polymerase chain reaction (PCR)

被引:12
作者
Daxboeck, F [1 ]
Dornbusch, HJ
Krause, R
Assadian, O
Wenisch, C
机构
[1] Univ Vienna, Div Hosp Hyg, Clin Inst Hyg & Med Microbiol, Vienna, Austria
[2] Graz Univ, Dept Internal Med, Div Infect Dis, Graz, Austria
[3] Graz Univ, Dept Pediat, Div Pediat Hematol & Oncol, Graz, Austria
关键词
BACTEC; 9000; series; eubacterial 165 rDNA PCR; panfungal 185 rDNA PCR;
D O I
10.1016/j.diagmicrobio.2003.08.001
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 4 条
[1]   Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections [J].
Cockerill, FR ;
Reed, GS ;
Hughes, JG ;
Torgerson, CA ;
Vetter, EA ;
Harmsen, WS ;
Dale, JS ;
Roberts, GD ;
Ilstrup, DM ;
Henry, NK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) :1469-1472
[2]   Detection and identification of fungal pathogens in blood by using molecular probes [J].
Einsele, H ;
Hebart, H ;
Roller, G ;
Loffler, J ;
Rothenhofer, I ;
Muller, CA ;
Bowden, RA ;
vanBurik, JA ;
Engelhard, D ;
Kanz, L ;
Schumacher, U .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) :1353-1360
[3]   Direct identification of bacteria from positive blood cultures by amplification and sequencing of the 16S rRNA gene: Evaluation of BACTEC 9240 instrument true-positive and false-positive results [J].
Qian, QF ;
Tang, YW ;
Kolbert, CP ;
Torgerson, CA ;
Hughes, JG ;
Vetter, EA ;
Harmsen, WS ;
Montgomery, SO ;
Cockerill, FR ;
Persing, DH .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (10) :3578-3582
[4]   16S RIBOSOMAL DNA AMPLIFICATION FOR PHYLOGENETIC STUDY [J].
WEISBURG, WG ;
BARNS, SM ;
PELLETIER, DA ;
LANE, DJ .
JOURNAL OF BACTERIOLOGY, 1991, 173 (02) :697-703