Assessment of Ventricular Septal Defect Size and Morphology by Three-Dimensional Transthoracic Echocardiography

被引:12
|
作者
Hadeed, Khaled [1 ]
Hascoet, Sebastien [1 ,3 ]
Amadieu, Romain [1 ]
Karsenty, Clement [1 ,3 ]
Cuttone, Fabio [2 ]
Leobon, Bertrand [2 ]
Dulac, Yves [1 ]
Acar, Philippe [1 ]
机构
[1] CHU, Children Hosp, Pediat Cardiol Unit, Toulouse, France
[2] CHU, Children Hosp, Cardiac Surg Unit, Toulouse, France
[3] INSERM, UMR1048, Inst Malad Metab & Cardiovasc, F-31000 Toulouse, France
关键词
Ventricular septal defect; Three-dimensional echocardiography; Children; TRANSCATHETER CLOSURE; INTERVENTIONAL CLOSURE; DEVICE CLOSURE; OCCLUDER; FEASIBILITY; ACCURACY; CHILDREN; INSIGHTS; VSD;
D O I
10.1016/j.echo.2016.04.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Morphologic description of ventricular septal defect (VSD) is mandatory before performing the newly developed transcatheter closure procedure. Inaccurate estimation of defect size has been reported using conventional two-dimensional (2D) transthoracic echocardiography (TTE). The aim of this study was to assess VSD morphology and size using three-dimensional (3D) TTE compared with 2D TTE and surgery. Methods: Forty-eight children aged 21.4 +/- 29.3 months with isolated muscular (n = 11 [22.9%]) and membranous (n = 37 [77.1%]) VSDs were prospectively included. Three-dimensional images were acquired using full-volume single-beat mode. Minimal diameter, maximal diameter, and systolic and diastolic VSD areas were measured from 3D data sets using multiplanar reconstruction mode (QLAB 9). Maximal-to-minimal VSD diameter ratio was used to assess VSD geometry. Linear regression analysis and the Bland-Altman method were used to compare 3D measurements with 2D and surgical measurements in a subgroup of 15 patients who underwent surgical VSD closure. Results: VSD 3D diameters and areas were measured in all patients (100%; 95% CI, 92.6%-100%). Maximal diameter was lower on 2D TTE compared with 3D TTE (7.3 vs 11.3 mm, P < .0001). Mean bias was 4 mm, with 95% of values ranging from -1.76 to 9.75 mm. Correlation between 3D maximal diameter and surgical diameter was strong (r(2) = 0.97, P < .0001), while correlation between maximal 2D diameter and surgical diameter was moderate (r(2) = 0.63, P < .0001). VSDs had an oval shape when assessed by 3D TTE. Maximal-to-minimal diameter ratio assessed by 3D TTE was significantly higher in muscular VSDs compared with membranous VSDs (3.20 +/- 1.51 vs 2.13 +/- 1.28, respectively, P = .01). VSD area variation throughout the cardiac cycle was 32% and was higher in muscular compared with membranous VSDs (49% vs 26%, P = .0001). Conclusions: Three-dimensional TTE allows better VSD morphologic and maximal diameter assessment compared with 2D TTE. VSD shape and its changes during the cardiac cycle can be visually and quantitatively displayed. Three-dimensional echocardiography may thus be particularly useful before and during percutaneous VSD closure.
引用
收藏
页码:777 / 785
页数:9
相关论文
共 50 条
  • [21] Three-dimensional transesophageal echocardiography in the diagnosis of atrial septal aneurysm with patent foramen ovale in a patient with ventricular septal defect
    Takayanagi Y.
    Yuda S.
    Sugio H.
    Ichimura M.
    Masuda-Yamamoto H.
    Tanaka-Saito N.
    Miura T.
    Journal of Echocardiography, 2012, 10 (3) : 101 - 103
  • [22] A study of clinical implementation of ventricular septal defect closure using three transthoracic approaches
    Cai, Longren
    Zeng, Ganhua
    Li, Yan
    Peng, Xinghua
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (10): : 11833 - 11841
  • [23] Transthoracic closure of ventricular septal defects guided by transesophageal echocardiography
    Sun Kai-Peng
    Ning, Xu
    Hang Gui-Can
    Huang Jiang-Shan
    Qiang, Chen
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 28 (02): : 250 - 256
  • [24] Presentation of mitral valve cleft with concurrent atrial septal defect and ventricular septal defect detected by three-dimensional transesophageal echocardiography: a case report
    Alizadehasl, Azin
    Amini-Salehi, Ehsan
    Jebelli, Seyedeh Fatemeh Hosseini
    Hosseini, Kaveh
    Aliabadi, Azam Yalameh
    Yazzaf, Rosa
    Nobakht, Sara
    JOURNAL OF MEDICAL CASE REPORTS, 2024, 18 (01)
  • [25] Usefulness of live three-dimensional transthoracic echocardiography in the characterization of atrial septal defects in adults
    Mehmood, F
    Vengala, S
    Nanda, NC
    Dod, HS
    Sinha, A
    Miller, AP
    Khanna, D
    Misra, VK
    Lloyd, SG
    Upendram, S
    Bodiwala, K
    McMahon, WS
    Kasliwal, RR
    Chouhan, N
    Govinder, M
    Pacifico, AD
    Kirklin, JK
    McGiffin, DC
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2004, 21 (08): : 707 - 713
  • [26] Incremental Value of Live/Real Time Three-Dimensional Transthoracic Echocardiography in the Assessment of Right Ventricular Masses
    Reddy, Venkataramana K.
    Faulkner, Michael
    Bandarupalli, Naveen
    Nanda, Navin C.
    Singh, Preeti
    Dutta, Rajarshi
    Singh, Anurag
    Pothineni, Koteswara R.
    Dod, Harvinder S.
    Bhardwaj, Ravindra
    Warden, Bradford E.
    Beto, Robert J.
    Jain, Abnash C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (05): : 598 - 609
  • [27] Amplatzer Septal Occluder Closure of Atrial Septal Defect: Evaluation of Transthoracic Echocardiography, Cardiac CT, and Transesophageal Echocardiography
    Ko, Sheung-Fat
    Liang, Chi-Di
    Yip, Hon-Kan
    Huang, Chung-Cheng
    Ng, Shu-Hang
    Huang, Chien-Fu
    Chen, Min-Chi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1522 - 1529
  • [28] Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography
    Shinichi Fujimoto
    Reiko Mizuno
    Yoshihito Nakagawa
    Kazuhiro Dohi
    Hiroshi Nakano
    The International Journal of Cardiac Imaging, 1998, 14 : 385 - 390
  • [29] Live three-dimensional transthoracic echocardiographic assessment of transcatheter closure of atrial septal defect and patent foramen ovale
    Sinha, A
    Nanda, NC
    Misra, V
    Khanna, D
    Dod, HS
    Vengala, S
    Mehmood, F
    Singh, V
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2004, 21 (08): : 749 - 753
  • [30] Comparison of two- and three-dimensional transthoracic echocardiography for measurement of aortic annulus diameter in children
    Martin, Romain
    Hascoet, Sebastien
    Dulac, Yves
    Peyre, Marianne
    Mejean, Simon
    Hadeed, Khaled
    Cazavet, Alexandre
    Leobon, Bertrand
    Acar, Philippe
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2013, 106 (10) : 492 - 500