Determination of N-nitrosamines by automated dispersive liquid-liquid microextraction integrated with gas chromatography and mass spectrometry

被引:27
作者
Amayreh, Mousa [1 ]
Chanbasha, Basheer [1 ]
Alhooshani, Khalid [1 ]
Mu'azu, Nuhu Dalhat [2 ]
Lee, Hian Kee [3 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[2] Univ Dammam, Dept Environm Engn, Coll Engn, Dammam, Saudi Arabia
[3] Natl Univ Singapore, Dept Chem, Singapore 117548, Singapore
关键词
Automation; Dispersive liquid-liquid microextraction; Environmental analysis; Gas chromatography with mass spectrometry; N-nitrosamines; SOLID-PHASE MICROEXTRACTION; RESPONSE-SURFACE METHODOLOGY; LOW-POLARITY WATER; PHENOLIC-COMPOUNDS; ORGANIC-COMPOUNDS; SINGLE-DROP; FLAX SHIVES; NITROSODIMETHYLAMINE; OPTIMIZATION; EXTRACTION;
D O I
10.1002/jssc.201401043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated dispersive liquid-liquid microextraction integrated with gas chromatography and mass spectrometric procedure was developed for the determination of three N-nitrosamines (N-nitroso-di-n-propylamine, N-nitrosopiperidine, and N-nitroso di-n-butylamine) in water samples. Response surface methodology was employed to optimize relevant extraction parameters including extraction time, dispersive solvent volume, water sample pH, sodium chloride concentration, and agitation (stirring) speed. The optimal dispersive liquid-liquid microextraction conditions were 28 min of extraction time, 33 L of methanol as dispersive solvent, 722 rotations per minute of agitation speed, 23% w/v sodium chloride concentration, and pH of 10.5. Under these conditions, good linearity for the analytes in the range from 0.1 to 100 g/L with coefficients of determination (r(2)) from 0.988 to 0.998 were obtained. The limits of detection based on a signal-to-noise ratio of 3 were between 5.7 and 124 ng/L with corresponding relative standard deviations from 3.4 to 5.9% (n = 4). The relative recoveries of N-nitroso-di-n-propylamine, N-nitrosopiperidine, and N-nitroso di-n-butylamine from spiked groundwater and tap water samples at concentrations of 2 g/L of each analyte (mean +/- standard deviation, n = 3) were (93.9 +/- 8.7), (90.6 +/- 10.7), and (103.7 +/- 8.0)%, respectively. The method was applied to determine the N-nitrosamines in water samples of different complexities, such as tap water, and groundwater, before and after treatment, in a local water treatment plant.
引用
收藏
页码:1741 / 1748
页数:8
相关论文
共 42 条
[1]   Ultrasound-Assisted Ion-Pair Dispersive Liquid-Liquid Microextraction of Trace Amounts of Lead in Water Samples Prior to Graphite Furnace Atomic Absorption Spectrometry Determination [J].
Afzali, Daryoush ;
Mohadesi, Ali Reza ;
Falahnejad, Masoumeh ;
Bahadori, Behnoosh .
JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (01) :161-165
[2]   Application of the central composite design and response surface methodology to the advanced treatment of olive oil processing wastewater using Fenton's peroxidation [J].
Ahmadi, M ;
Vahabzadeh, F ;
Bonakdarpour, B ;
Mofarrah, E ;
Mehranian, M .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 123 (1-3) :187-195
[3]  
Anderson MarkJ., 2005, RSM SIMPLIFIED OPTIM
[4]   Five Years of Dispersive Liquid-Liquid Microextraction [J].
Andruch, Vasil ;
Balogh, Ioseph S. ;
Kocurova, Livia ;
Sandrejova, Jana .
APPLIED SPECTROSCOPY REVIEWS, 2013, 48 (03) :161-259
[5]  
Aristidi N. A., 2009, TALANTA, V79, P86
[6]  
BARNES JM, 1954, BRIT J IND MED, V11, P167
[7]   Response surface methodology (RSM) as a tool for optimization in analytical chemistry [J].
Bezerra, Marcos Almeida ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Villar, Leonardo Silveira ;
Escaleira, Luciane Amlia .
TALANTA, 2008, 76 (05) :965-977
[8]   Dispersive liquid-liquid microextraction for the determination of macrocyclic lactones in milk by liquid chromatography with diode array detection and atmospheric pressure chemical ionization ion-trap tandem mass spectrometry [J].
Campillo, Natalia ;
Vinas, Pilar ;
Ferez-Melgarejo, Gema ;
Hernandez-Cordoba, Manuel .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1282 :20-26
[9]   Determination of volatile nitrosamines in meat products by microwave-assisted extraction and dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry [J].
Campillo, Natalia ;
Vinas, Pilar ;
Martinez-Castillo, Nelson ;
Hernandez-Cordoba, Manuel .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (14) :1815-1821
[10]   High-performance liquid chromatography with fluorescence detection for aqueous analysis of nanogram-level N-nitrosodimethylamine [J].
Cha, W ;
Fox, P ;
Nalinakumari, B .
ANALYTICA CHIMICA ACTA, 2006, 566 (01) :109-116