3D Fluid-Attenuated Inversion Recovery Imaging: Reduced CSF Artifacts and Enhanced Sensitivity and Specificity for Subarachnoid Hemorrhage

被引:35
作者
Lummel, N. [1 ]
Schoepf, V. [2 ,3 ]
Burke, M. [4 ]
Brueckmann, H. [1 ]
Linn, J. [1 ]
机构
[1] Univ Munich, Dept Neuroradiol, D-81377 Munich, Germany
[2] Med Univ Vienna, Div Neuro & Musculoskeletal Radiol, Dept Radiol, Vienna, Austria
[3] Med Univ Vienna, MR Ctr Excellence, Vienna, Austria
[4] GE Healthcare, Solingen, Germany
关键词
BLOOD-FLOW ARTIFACTS; SLICE POSITION KRISP; CEREBROSPINAL-FLUID; MR-IMAGES; INTRAVENTRICULAR HEMORRHAGE; PULSE SEQUENCE; FLAIR IMAGES; SPACE; BRAIN; HYPERINTENSITY;
D O I
10.3174/ajnr.A2682
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: FLAIR images are highly sensitive for SAH. However, CSF flow artifacts caused by conventional FLAIR can produce false-positive results. Here, we compare 3D and 3D FLAIR sequences, focusing on their potential for containing these artifacts and their sensitivity and specificity for detection of SAHs. MATERIALS AND METHODS: We evaluated the following 4 FLAIR sequences: 1) 2D FLAIR at 1.51, 2) 2D FLAIR, 3) 2D PROPELLER-FLAIR, and 4) 3D Cube-FLAIR at 3T. All sequences were performed in 5 healthy volunteers; sequences 2 and 4 were also performed under routine conditions in 10 patients with focal epilepsy and in 10 patients with SAH. Two neuroradiologists independently conducted the analysis. The presence of flow artifacts in the ventricles and cisterns of healthy volunteers and patients with epilepsy was evaluated and scored on a 4-point scale. Mean values were calculated and compared by using paired t tests. Sensitivity and specificity for SAH detection in sequences 2 and 4 were determined. RESULTS: Cube-FLAIR showed almost no CSF artifacts in the volunteers and the patients with epilepsy; therefore, it was superior to any other FLAIR (P < .001). Sensitivity and specificity of SAH detection by 3T FLAIR were 58.3% and 89.4%, respectively, whereas Cube-FLAIR had a sensitivity of 95% and a specificity of 100%. CONCLUSIONS: Cube-FLAIR allows FLAIR imaging with almost no CSF artifacts and is, thus, particularly useful for SAH detection.
引用
收藏
页码:2054 / 2060
页数:7
相关论文
共 33 条
[21]   Abnormal hyperintensity within the subarachnoid space evaluated by fluid-aftenuated inversion-recovery MR imaging: a spectrum of central nervous system diseases [J].
Maeda, M ;
Yagishita, A ;
Yamamoto, T ;
Sakuma, H ;
Takeda, K .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 6) :L192-L201
[22]   Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T [J].
Naganawa, S ;
Koshikawa, T ;
Nakamura, T ;
Kawai, H ;
Fukatsu, H ;
Ishigaki, T ;
Komada, T ;
Maruyama, K ;
Takizawa, O .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1901-1908
[23]  
Noguchi K, 2000, AM J NEURORADIOL, V21, P923
[24]   ACUTE SUBARACHNOID HEMORRHAGE - MR-IMAGING WITH FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES [J].
NOGUCHI, K ;
OGAWA, T ;
INUGAMI, A ;
TOYOSHIMA, H ;
SUGAWARA, S ;
HATAZAWA, J ;
FUJITA, H ;
SHIMOSEGAWA, E ;
KANNO, I ;
OKUDERA, T ;
UEMURA, K ;
YASUI, N .
RADIOLOGY, 1995, 196 (03) :773-777
[25]   Evaluation of a FLAIR sequence designed to reduce CSF and blood flow artifacts by use of k-space reordered by inversion time at each slice position (KRISP) in high grade gliomas of the brain [J].
Oatridge, A ;
Curati, WL ;
Herlihy, AH ;
Hajnal, JV ;
Virji, N ;
Puri, BK ;
Bydder, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (02) :251-256
[26]  
Pipe JG, 1999, MAGNET RESON MED, V42, P963, DOI 10.1002/(SICI)1522-2594(199911)42:5<963::AID-MRM17>3.0.CO
[27]  
2-L
[28]  
Sohn CH, 2005, AM J NEURORADIOL, V26, P662
[29]   Hyperintensity in the subarachnoid space on FLAIR MRI [J].
Stuckey, Stephen L. ;
Goh, Tony D. ;
Heffernan, Theresa ;
Rowan, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :913-921
[30]  
Tanaka N, 2000, AM J NEURORADIOL, V21, P1095