Using a smartwatch electrocardiogram to detect abnormalities associated with sudden cardiac arrest in young adults

被引:32
作者
Nasarre, Mathieu [1 ]
Strik, Marc [1 ,2 ]
Ramirez, Francisco Daniel [1 ,2 ,3 ]
Buliard, Samuel [1 ]
Marchand, Hugo [1 ]
Abu-Alrub, Saer [1 ,2 ]
Ploux, Sylvain [1 ,2 ]
Haissaguerre, Michel [1 ,2 ]
Bordachar, Pierre [1 ,2 ]
机构
[1] Bordeaux Univ Hosp CHU, Cardio Thorac Unit, F-33600 Pessac, France
[2] Fdn Bordeaux Univ, IHU Liryc Electrophysiol & Heart Modeling Inst, F-33600 Pessac, France
[3] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
来源
EUROPACE | 2022年 / 24卷 / 03期
基金
加拿大健康研究院;
关键词
Electrocardiography; Brugada; Long QT; Smartwatch; Sudden cardiac arrest; Sudden cardiac death; Pre-excitation; Arrhythmogenic right ventricular cardiomyopathy; Hypertrophic cardiomyopathy; Young adults; DEATH;
D O I
10.1093/europace/euab192
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Smartwatch electrocardiograms (ECGs) could facilitate the detection of sudden cardiac arrest (SCA)-associated abnormalities. We evaluated the feasibility of using smartwatch-derived ECGs for detecting SCA-associated abnormalities in young adults and its agreement with 12-lead ECGs. Methods and results Twelve-lead and Apple Watch ECGs were registered in 155 healthy volunteers and 67 patients aged 18-45 years with diagnosis and ECG signs of long-QT syndrome (n = 10), Brugada syndrome (n = 12), ventricular pre-excitation (n = 19), hypertrophic cardiomyopathy (HCM, n = 13), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC/D, n = 13). Cardiologists separately analysed 12-lead ECGs and the smartwatch ECGs taken from the left wrist (AW-I) and then from chest positions V1, V3, and V6 (AW-4). Compared with AW-I, AW-4 improved the classification of ECGs as 'abnormal', increasing the sensitivity from 64% to 89% (P < 0.01). Pre-excitation was detected in most cases using AW-I (sensitivity 89%) and in all cases using AW-4 (sensitivity 100%, P = 0.48 compared with AW-I, specificity 100% for both). Brugada was missed using AW-I but was detected in 11/12 patients using AW-4 (sensitivity 92%, specificity 100%, P = 0.003). Long QT was detected in 8/10 cases using AW-I (sensitivity 80%, specificity 100%) and in 9 patients using AW-4 (sensitivity 90%, specificity 100%, P > 0.99). Hypertrophic cardiomyopathy was correctly suspected using AW-I and AW-4 (sensitivity 92% and 85%, specificity 85%, and 100%, P > 0.99). AW-I was mostly (62%) considered normal in ARVC/D whereas AW-4 was useful in suspecting ARVC/D (100% sensitivity, 99% specificity, P = 0.004). Conclusions Detection of SCA-associated ECG abnormalities (pre-excitation, Brugada patterns, long QT, and signs suggestive of HCM and ARVC/D) is possible with an ECG smartwatch.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 17 条
[11]   Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation [J].
Perez, Marco V. ;
Mahaffey, Kenneth W. ;
Hedlin, Haley ;
Rumsfeld, John S. ;
Garcia, Ariadna ;
Ferris, Todd ;
Balasubramanian, Vidhya ;
Russo, Andrea M. ;
Rajmane, Amol ;
Cheung, Lauren ;
Hung, Grace ;
Lee, Justin ;
Kowey, Peter ;
Talati, Nisha ;
Nag, Divya ;
Gummidipundi, Santosh E. ;
Beatty, Alexis ;
Hills, Mellanie True ;
Desai, Sumbul ;
Granger, Christopher B. ;
Desai, Manisha ;
Turakhia, Mintu P. .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (20) :1909-1917
[12]   Brugada syndrome: A general cardiologist's perspective [J].
Polovina, Marija M. ;
Vukicevic, Milica ;
Banko, Bojan ;
Lip, Gregory Y. H. ;
Potpara, Tatjana S. .
EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2017, 44 :19-27
[13]   Long-QT Syndrome From Genetics to Management [J].
Schwartz, Peter J. ;
Crotti, Lia ;
Insolia, Roberto .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (04) :868-877
[14]   Accuracy of Apple Watch for Detection of Atrial Fibrillation [J].
Seshadri, Dhruv R. ;
Bittel, Barbara ;
Browsky, Dalton ;
Houghtaling, Penny ;
Drummond, Colin K. ;
Desai, Milind Y. ;
Gillinov, A. Marc .
CIRCULATION, 2020, 141 (08) :702-703
[15]   Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes [J].
Spaccarotella, Carmen Anna Maria ;
Polimeni, Alberto ;
Migliarino, Serena ;
Principe, Elisa ;
Curcio, Antonio ;
Mongiardo, Annalisa ;
Sorrentino, Sabato ;
De Rosa, Salvatore ;
Indolfi, Ciro .
JAMA CARDIOLOGY, 2020, 5 (10) :1176-1180
[16]   Validating QT-Interval Measurement Using the Apple Watch ECG to Enable Remote Monitoring During the COVID-19 Pandemic [J].
Strik, Marc ;
Caillol, Theo ;
Ramirez, F. Daniel ;
Abu-Alrub, Saer ;
Marchand, Hugo ;
Welte, Nicolas ;
Ritter, Philippe ;
Haissaguerre, Michel ;
Ploux, Sylvain ;
Bordachar, Pierre .
CIRCULATION, 2020, 142 (04) :416-418
[17]  
U.S. Food & Drug Administartion, 2020, STAT FDA COMM SCOTT