Comprehensive two-dimensional gas chromatography and time-of-flight mass spectrometry detection with a 50 ms modulation period

被引:15
作者
Bahaghighat, H. Daniel [1 ,2 ]
Freye, Chris E. [1 ]
Gough, Derrick, V [1 ]
Synovec, Robert E. [1 ]
机构
[1] Univ Washington, Dept Chem, Box 351700, Seattle, WA 98195 USA
[2] US Mil Acad, Dept Chem & Life Sci, West Point, NY 10996 USA
关键词
Ultra-fast modulation; Comprehensive two-dimensional; Time-of-flight mass spectrometry; Chemometric deconvolution; THERMAL MODULATOR; DIFFERENTIAL FLOW; VALVE; IONIZATION;
D O I
10.1016/j.chroma.2018.11.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultrafast flow modulation period, P-M of 50 ms, for comprehensive two-dimensional (2D) gas chromatography (GC x GC) with time-of-flight mass spectrometry (TOFMS) detection is demonstrated, producing narrow peak widths, W-2(4 sigma width-at-base on the D-2 dimension), demonstrating the potential for ultrafast (2D) separations with high peak capacity. The modulator is a pulse flow valve that injects a narrow pulse of carrier gas at a user defined P-M, at the union between the D-1 and D-2 columns. The raw data produced combines the properties of vacancy chromatography and frontal analysis. Deconvolution of the raw data using unconstrained multivariate curve resolution alternating least squares (MCR-ALS) analysis facilitates identification and quantification for overlapped analyte peaks. The peak profile loadings obtained from MCR-ALS are converted into traditional appearing GC x GC data through a process commonly used with frontal analysis. An 18-component test mixture at seven different injected mass levels was studied. The D-2 peaks generated ranged from an W-2 of 16 to 36 ms with an average of 26 ms. At an on-column injected mass of 14 ng per analyte, an average mass spectral match value, MV, of 822 was achieved using in-house collected spectra for comparison, with an average match value RSD of 7.1%. Calibration of overlapped test analytes was evaluated using the areas of the MCR-ALS loadings, with excellent quantification demonstrated. The advancement demonstrated in modulation performance for GC x GC represents a significant decrease in P-M as most commercial modulators have a minimum P-M of 1 s, while maintaining the benefits of a duty cycle of essentially 1.0, which promises to enable new chemical analyzer designs, compatible with the vacuum requirements of the TOFMS detector. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 41 条
[1]   Recent advances in modulator technology for comprehensive two dimensional gas chromatography [J].
Bahaghighat, H. Daniel ;
Freye, Chris E. ;
Synovec, Robert E. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 113 :379-391
[2]   Ultrafast separations via pulse flow valve modulation to enable high peak capacity multidimensional gas chromatography [J].
Bahaghighat, H. Daniel ;
Freye, Chris E. ;
Gough, Derrick V. ;
Sudol, Paige E. ;
Synovec, Robert E. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1573 :115-124
[3]   Flow optimization in one-dimensional and comprehensive two-dimensional gas chromatography [J].
Blumberg, Leonid M. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 :27-38
[4]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[5]   Thermal modulator array for analyte modulation and comprehensive two-dimensional gas chromatography [J].
Burger, BV ;
Snyman, T ;
Burger, WJG ;
van Rooyen, WF .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (1-2) :123-128
[6]   Partial modulation method via pulsed flow modulator for comprehensive two-dimensional gas chromatography [J].
Cai, HM ;
Stearns, SD .
ANALYTICAL CHEMISTRY, 2004, 76 (20) :6064-6076
[7]  
Deans D.R., 1968, CHROMATOGRAPHIA, V1, P18
[8]   Development of a thermal desorption modulator for gas chromatography [J].
deGeus, HJ ;
deBoer, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :137-151
[9]   Comparison of cryogenic and differential flow (forward and reverse fill/flush) modulators and applications to the analysis of heavy petroleum cuts by high-temperature comprehensive gas chromatography [J].
Duhamel, Chloe ;
Cardinael, Pascal ;
Peulon-Agasse, Valerie ;
Firor, Roger ;
Pascaud, Laurent ;
Semard-Jousset, Gaelle ;
Giusti, Pierre ;
Livadaris, Vincent .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1387 :95-103
[10]   Modulation in comprehensive two-dimensional gas chromatography: 20 years of innovation [J].
Edwards, Matthew ;
Mostafa, Ahmed ;
Gorecki, Tadeusz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) :2335-2349