Comprehensive two-dimensional gas chromatography and time-of-flight mass spectrometry detection with a 50 ms modulation period

被引:15
|
作者
Bahaghighat, H. Daniel [1 ,2 ]
Freye, Chris E. [1 ]
Gough, Derrick, V [1 ]
Synovec, Robert E. [1 ]
机构
[1] Univ Washington, Dept Chem, Box 351700, Seattle, WA 98195 USA
[2] US Mil Acad, Dept Chem & Life Sci, West Point, NY 10996 USA
关键词
Ultra-fast modulation; Comprehensive two-dimensional; Time-of-flight mass spectrometry; Chemometric deconvolution; THERMAL MODULATOR; DIFFERENTIAL FLOW; VALVE; IONIZATION;
D O I
10.1016/j.chroma.2018.11.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultrafast flow modulation period, P-M of 50 ms, for comprehensive two-dimensional (2D) gas chromatography (GC x GC) with time-of-flight mass spectrometry (TOFMS) detection is demonstrated, producing narrow peak widths, W-2(4 sigma width-at-base on the D-2 dimension), demonstrating the potential for ultrafast (2D) separations with high peak capacity. The modulator is a pulse flow valve that injects a narrow pulse of carrier gas at a user defined P-M, at the union between the D-1 and D-2 columns. The raw data produced combines the properties of vacancy chromatography and frontal analysis. Deconvolution of the raw data using unconstrained multivariate curve resolution alternating least squares (MCR-ALS) analysis facilitates identification and quantification for overlapped analyte peaks. The peak profile loadings obtained from MCR-ALS are converted into traditional appearing GC x GC data through a process commonly used with frontal analysis. An 18-component test mixture at seven different injected mass levels was studied. The D-2 peaks generated ranged from an W-2 of 16 to 36 ms with an average of 26 ms. At an on-column injected mass of 14 ng per analyte, an average mass spectral match value, MV, of 822 was achieved using in-house collected spectra for comparison, with an average match value RSD of 7.1%. Calibration of overlapped test analytes was evaluated using the areas of the MCR-ALS loadings, with excellent quantification demonstrated. The advancement demonstrated in modulation performance for GC x GC represents a significant decrease in P-M as most commercial modulators have a minimum P-M of 1 s, while maintaining the benefits of a duty cycle of essentially 1.0, which promises to enable new chemical analyzer designs, compatible with the vacuum requirements of the TOFMS detector. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [1] Dynamic pressure gradient modulation for comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detection
    Schoneich, Sonia
    Gough, Derrick, V
    Trinklein, Timothy J.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1620
  • [2] Detection of an Extended Human Volatome with Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry
    Phillips, Michael
    Cataneo, Renee N.
    Chaturvedi, Anirudh
    Kaplan, Peter D.
    Libardoni, Mark
    Mundada, Mayur
    Patel, Urvish
    Zhang, Xiang
    PLOS ONE, 2013, 8 (09):
  • [3] The detection of various opiates and benzodiazepines by comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry
    Guthery, Bill
    Bassindale, Alan
    Pillinger, Colin T.
    Morgan, Geraint H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (03) : 340 - 348
  • [4] Comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry peak sorting algorithm
    Oh, Cheolhwan
    Huang, Xiaodong
    Regnier, Fred E.
    Buck, Charles
    Zhang, Xiang
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 205 - 215
  • [5] Data Analysis Tool for Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry
    Castillo, Sandra
    Mattila, Ismo
    Miettinen, Jarkko
    Oresic, Matej
    Hyotylainen, Tuulia
    ANALYTICAL CHEMISTRY, 2011, 83 (08) : 3058 - 3067
  • [6] Application of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry in human metabolomic studies
    Zrostlikova, Jitka
    Binkley, Joe
    Wojtowicz, Petr
    Adam, Tomas
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (13) : 1333 - 1340
  • [7] Identification of petroleum aromatic fraction by comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    Wang HuiTong
    Weng Na
    Zhang ShuiChang
    Zhu GuangYou
    Chen JianPing
    Wei CaiYun
    CHINESE SCIENCE BULLETIN, 2010, 55 (19): : 2039 - 2045
  • [8] Identification of petroleum aromatic fraction by comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    WANG HuiTong1
    2 Key Laboratory of Petroleum Geochemistry of PetroChina
    3 State key laboratory of enhanced oil recovery
    Chinese Science Bulletin, 2010, 55 (19) : 2039 - 2045
  • [9] Evaluation of comprehensive two-dimensional gas chromatography - time-of-flight mass spectrometry for the determination of pesticides in tobacco
    Cochran, Jack
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 202 - 210
  • [10] Application of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry in human metabolomic studies
    Jitka Zrostlikova
    Joe Binkley
    Petr Wojtowicz
    Tomas Adam
    Journal of Analytical Chemistry, 2011, 66 : 1333 - 1340