Interference of engineered nanomaterials in flow cytometry: A case study

被引:21
作者
Bohmer, Nils [1 ]
Rippl, Alexandra [1 ]
May, Sarah [1 ]
Walter, Aurelie [2 ]
Heo, Min Beom [3 ]
Kwak, Minjeong [3 ]
Roesslein, Matthias [1 ]
Song, Nam Woong [3 ]
Wick, Peter [1 ]
Hirsch, Cordula [1 ]
机构
[1] Empa, Swiss Fed Labs Mat Sci & Technol, Lab Particles Biol Interact, Lerchenfeldstr 5, CH-9014 St Gallen, Switzerland
[2] Ecole Polytech Fed Lausanne, Powder Technol Lab, Inst Mat, CH-1015 Lausanne, Switzerland
[3] KRISS, Daejeon 305340, South Korea
关键词
Nanomaterials; Flow cytometry; Interference; In vitro assay; Human cells; Fluorescence; MESOPOROUS SILICA NANOPARTICLES; IN-VITRO TESTS; CARBON NANOTUBES; PROTEIN CORONA; REACTIVE OXYGEN; CELL; FLUORESCENCE; IMPACT; ASSAY; ADSORPTION;
D O I
10.1016/j.colsurfb.2018.09.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nanotechnology is regarded as the enabling technology of the 21st century. However, only a relatively small number of nano-enabled medical and healthcare products finally made their way to the market. There are several reasons why such innovative approaches fail in translation, with one key factor being the uncertainty surrounding their safety assessment. Although well described, interference reactions of engineered nanomaterials (ENM) with classical cytotoxicity assays remain a major source of uncertainty. Flow cytometry is a powerful, widely used, in vitro technique. Its readout is based on the detection of refracted laser light and fluorescence signals. It is therefore susceptible to ENM interference. Here we investigated possible interferences of ENM in the Annexin V/propidium iodide (PI) assay, which quantifies apoptotic and necrotic cell populations by flow cytometry. Two case studies were conducted using either silica or gold nanoparticles differing in size, specific surface area and surface chemistry. Both ENM types were found to cause distinct interference reactions at realistic concentrations. Silica particles induced false-positive signals; however only in the absence of a protein corona and in conjunction with a particular fluorophore combination (FITC/PI). In contrast, gold particles led to complex quenching effects which were only marginally influenced by the presence of proteins and occurred for both fluorophore combinations analyzed. We present a versatile spike-in approach which is applicable to all ENM and cell types. It further allows for the identification of a broad range of different interference phenomena, thereby increasing the reliability and quality of flow cytometry and ENM hazard assessment.
引用
收藏
页码:635 / 645
页数:11
相关论文
共 40 条
  • [1] Fluoroimmunoassay for antigen based on fluorescence quenching signal of gold nanoparticles
    Ao, LM
    Gao, F
    Pan, BF
    He, R
    Cui, DX
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1104 - 1106
  • [2] The reliability and limits of the MTT reduction assay for carbon nanotubes-cell interaction
    Belyanskaya, Larisa
    Manser, Plus
    Spohn, Philipp
    Bruinink, Arle
    Wick, Peter
    [J]. CARBON, 2007, 45 (13) : 2643 - 2648
  • [3] Spectroscopic analysis confirms the interactions between single walled carbon nanotubes and various dyes commonly used to assess cytotoxicity
    Casey, A.
    Herzog, E.
    Davoren, M.
    Lyng, F. M.
    Byrne, H. J.
    Chambers, G.
    [J]. CARBON, 2007, 45 (07) : 1425 - 1432
  • [4] Understanding the nanoparticle-protein corona using methods to quantify exchange rates and affinities of proteins for nanoparticles
    Cedervall, Tommy
    Lynch, Iseult
    Lindman, Stina
    Berggard, Tord
    Thulin, Eva
    Nilsson, Hanna
    Dawson, Kenneth A.
    Linse, Sara
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (07) : 2050 - 2055
  • [5] Multimorphology Mesoporous Silica Nanoparticles for Dye Adsorption and Multicolor Luminescence Applications
    Chen, Jie
    Sheng, Ye
    Song, Yanhua
    Chang, Meiqi
    Zhang, Xiangting
    Cui, Lei
    Meng, Deyue
    Zhu, He
    Shi, Zhan
    Zou, Haifeng
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (03): : 3533 - 3545
  • [6] Advanced computational modeling for in vitro nanomaterial dosimetry
    DeLoid, Glen M.
    Cohen, Joel M.
    Pyrgiotakis, Georgios
    Pirela, Sandra V.
    Pal, Anoop
    Liu, Jiying
    Srebric, Jelena
    Demokritou, Philip
    [J]. PARTICLE AND FIBRE TOXICOLOGY, 2015, 12
  • [7] Dobrovolskaia MA, 2009, NAT NANOTECHNOL, V4, P411, DOI [10.1038/NNANO.2009.175, 10.1038/nnano.2009.175]
  • [8] The nanoparticle biomolecule corona: lessons learned - challenge accepted?
    Docter, D.
    Westmeier, D.
    Markiewicz, M.
    Stolte, S.
    Knauer, S. K.
    Stauber, R. H.
    [J]. CHEMICAL SOCIETY REVIEWS, 2015, 44 (17) : 6094 - 6121
  • [9] No king without a crown - impact of the nanomaterial-protein corona on nanobiomedicine
    Docter, Dominic
    Strieth, Sebastian
    Westmeier, Dana
    Hayden, Oliver
    Gao, Mingyuan
    Knauer, Shirley K.
    Stauber, Roland H.
    [J]. NANOMEDICINE, 2015, 10 (03) : 503 - 519
  • [10] Nanotoxicology
    Donaldson, K
    Stone, V
    Tran, CL
    Kreyling, W
    Borm, PJA
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2004, 61 (09) : 727 - 728