Multi-wall carbon nanotubes as a sensor and ferrocene dicarboxylic acid as a mediator for voltammetric determination of glutathione in hemolysed erythrocyte

被引:95
作者
Raoof, Jahan Bakhsh [1 ]
Ojani, Reza [1 ]
Karimi-Maleh, Hassan [1 ]
Hajmohamadi, Mohammad R. [1 ]
Biparva, Pouria [1 ]
机构
[1] Univ Mazandaran, Dept Analyt Chem, Electroanalyt Chem Res Lab, Fac Chem, Babol Sar, Iran
关键词
PASTE ELECTRODE; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; SELECTIVE DETERMINATION; ELECTROCHEMISTRY; OXIDATION; GRAPHITE; CYSTEINE; PLASMA; THIOLS;
D O I
10.1039/c1ay05031a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective electrochemical method was developed for determination of glutathione (GSH) in hemolysed erythrocyte using a ferrocene dicarboxylic acid modified carbon nanotubes paste electrode (FDCCNTPE). Cyclic voltammetry (CV), double potential-step chronoamperometry and differential pulse voltammetric (DPV) were used to investigate the suitability of ferrocene dicarboxylic acid at the surface of a multi-wall carbon nanotubes paste electrode as a mediator for the electrocatalytic oxidation of glutathione in aqueous solutions with various pH. The results showed that FDCCNTPE had high electrocatalytic activity for the electrooxidation of glutathione. Under optimum conditions (pH 7.00), oxidation of GSH occurs at a potential about 230 mV less positive than that at the unmodified carbon nanotubes paste electrode. The catalytic reaction rate constant, k(h) was calculated (1.98 x 10(4) M-1 s(-1)) using chronoamperometry. The electrocatalytic oxidation peak current of GSH showed two linear dynamic ranges with a detection limit of 0.2 mu mol L-1 GSH. The linear calibration ranges were obtained between 0.5-24 mu mol L-1 and 24-122 mu mol L-1 GSH using the DPV method. Finally, the proposed method was also examined as a selective, simple and precise electrochemical sensor for the determination of GSH in real samples such as hemolysed erythrocyte.
引用
收藏
页码:2637 / 2643
页数:7
相关论文
共 63 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[3]   New electrodes for old: from carbon nanotubes to edge plane pyrolytic graphite [J].
Banks, CE ;
Compton, RG .
ANALYST, 2006, 131 (01) :15-21
[4]   Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites [J].
Banks, CE ;
Davies, TJ ;
Wildgoose, GG ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2005, (07) :829-841
[5]   Nanomolar and Selective Determination of Epinephrine in the Presence of Norepinephrine Using Carbon Paste Electrode Modified with Carbon Nanotubes and Novel 2-(4-Oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazinecarbothioamide [J].
Beitollahi, Hadi ;
Karimi-Maleh, Hassan ;
Khabazzadeh, Hojatollah .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9848-9851
[6]   Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ [J].
Calvo-Marzal, Percy ;
Chumbimuni-Torres, Karin Y. ;
Hoehr, Nelci Fenalti ;
Kubota, Lauro T. .
CLINICA CHIMICA ACTA, 2006, 371 (1-2) :152-158
[7]  
Caussé E, 2000, ELECTROPHORESIS, V21, P2074, DOI 10.1002/1522-2683(20000601)21:10<2074::AID-ELPS2074>3.0.CO
[8]  
2-L
[9]   CVD synthesis of high-purity multiwalled carbon nanotubes using CaCO3 catalyst support for large-scale production [J].
Couteau, E ;
Hernadi, K ;
Seo, JW ;
Thiên-Nga, L ;
Mikó, C ;
Gaál, R ;
Forró, L .
CHEMICAL PHYSICS LETTERS, 2003, 378 (1-2) :9-17
[10]   TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .