Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing

被引:321
作者
Ge, Lei [1 ]
Yan, Jixian [1 ]
Song, Xianrang [2 ]
Yan, Mei [1 ]
Ge, Shenguang [3 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Shandong Tumor Hosp, Canc Res Ctr, Jinan 250117, Peoples R China
[3] Univ Jinan, Shandong Prov Key Lab Fluorine Chem & Chem Mat, Jinan 250022, Peoples R China
关键词
Electrochemiluminescence immunoassay; Lab on paper; Screen-printed electrode; Biomarker; Point-of-care testing; MICROFLUIDIC DEVICES; CHEMILUMINESCENCE DETECTION; CAMERA PHONES; TUMOR-MARKERS; ON-PAPER; LOW-COST; ELECTRONICS; TIME; FLOW; WAX;
D O I
10.1016/j.biomaterials.2011.10.065
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (mu PADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on mu PAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (II) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable mu RAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1024 / 1031
页数:8
相关论文
共 47 条
[1]   Inkjet-printed microfluidic multianalyte chemical sensing paper [J].
Abe, Koji ;
Suzuki, Koji ;
Citterio, Daniel .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :6928-6934
[2]  
[Anonymous], MODERN CLIN IMMUNOAS
[3]   Lab-on-Paper with Dual Electrochemical/Colorimetric Detection for Simultaneous Determination of Gold and Iron [J].
Apilux, Amara ;
Dungchai, Wijitar ;
Siangproh, Weena ;
Praphairaksit, Narong ;
Henry, Charles S. ;
Chailapakul, Orawon .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :1727-1732
[4]   Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper [J].
Bruzewicz, Derek A. ;
Reches, Meital ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3387-3392
[5]   Paper Microzone Plates [J].
Carrilho, Emanuel ;
Phillips, Scott T. ;
Vella, Sarah J. ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :5990-5998
[6]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[7]   Paper-Based ELISA [J].
Cheng, Chao-Min ;
Martinez, Andres W. ;
Gong, Jinlong ;
Mace, Charles R. ;
Phillips, Scott T. ;
Carrilho, Emanuel ;
Mirica, Katherine A. ;
Whitesides, George M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (28) :4771-4774
[8]  
Chitnis G, 2011, LAB CHIP, V11, P1161, DOI [10.1039/c0lc00512f, 10.1039/c01c00512f]
[9]   SEMIQUANTITATIVE SPECIFIC TEST PAPER FOR GLUCOSE IN URINE [J].
COMER, JP .
ANALYTICAL CHEMISTRY, 1956, 28 (11) :1748-1750
[10]   Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors [J].
Delaney, Jacqui L. ;
Hogan, Conor F. ;
Tian, Junfei ;
Shen, Wei .
ANALYTICAL CHEMISTRY, 2011, 83 (04) :1300-1306