Paper-based microchip electrophoresis for point-of-care hemoglobin testing

被引:39
|
作者
Hasan, Muhammad Noman [1 ]
Fraiwan, Arwa [1 ]
An, Ran [1 ]
Alapan, Yunus [1 ,2 ]
Ung, Ryan [1 ]
Akkus, Asya [1 ]
Xu, Julia Z. [3 ]
Rezac, Amy J. [4 ]
Kocmich, Nicholas J. [4 ]
Creary, Melissa S. [5 ]
Oginni, Tolulope [6 ]
Olanipekun, Grace Mfon [7 ]
Hassan-Hanga, Fatimah [8 ]
Jibir, Binta W. [9 ]
Gambo, Safiya [10 ]
Verma, Anil K. [11 ]
Bharti, Praveen K. [11 ]
Riolueang, Suchada [12 ]
Ngimhung, Takdanai [12 ]
Suksangpleng, Thidarat [12 ]
Thota, Priyaleela [13 ]
Werner, Greg [14 ]
Shanmugam, Rajasubramaniam [11 ]
Das, Aparup [11 ]
Viprakasit, Vip [15 ]
Piccone, Connie M. [16 ,17 ]
Little, Jane A. [18 ,19 ,20 ]
Obaro, Stephen K. [4 ,7 ]
Gurkan, Umut A. [1 ,21 ]
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Case Biomfg & Microfabricat Lab, Cleveland, OH 44106 USA
[2] Max Planck Inst Intelligent Syst, Phys Intelligence Dept, D-70569 Stuttgart, Germany
[3] Duke Univ, Med Ctr, Dept Med, Durham, NC 27707 USA
[4] Univ Nebraska Med Ctr, Coll Med, Div Pediat Infect Dis, Omaha, NE 68198 USA
[5] Univ Michigan, Sch Publ Hlth, Dept Hlth Management & Policy, Ann Arbor, MI 48109 USA
[6] eHealth Africa, Kano, Nigeria
[7] Int Fdn Infect Dis Nigeria, Abuja, Nigeria
[8] Bayero Univ, Aminu Kano Teaching Hosp, Kano, Nigeria
[9] Hasiya Bayero Pediat Hosp, Kano, Nigeria
[10] Murtala Muhammad Specialist Hosp, Kano, Nigeria
[11] ICMR Natl Inst Res Tribal Hlth, Nagpur Rd, Jabalpur 482003, Madhya Pradesh, India
[12] Mahidol Univ, Siriraj Hosp, Fac Med, Siriraj Thalassemia Ctr, Bangkok 10700, Thailand
[13] Hemex Hlth Inc, Portland, OR 97239 USA
[14] Thogus Prod, Avon Lake, OH USA
[15] Mahidol Univ, Siriraj Hosp, Fac Med, Div Haematol Oncol,Dept Pediat, Bangkok, Thailand
[16] Rainbow Babies & Children Hosp, Univ Hosp, Cleveland, OH 44106 USA
[17] Case Western Reserve Univ, Sch Med, Dept Pediat, Cleveland, OH 44106 USA
[18] Cleveland Med Ctr, Univ Hosp, Cleveland, OH 44106 USA
[19] Case Western Reserve Univ, Sch Med, Dept Hematol & Oncol, Cleveland, OH 44106 USA
[20] Univ N Carolina, Sch Med, Div Hematol & Oncol, Chapel Hill, NC 27516 USA
[21] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
SICKLE-CELL-DISEASE; LIQUID-CHROMATOGRAPHY; GLOBAL BURDEN; ANEMIA; HYDROXYUREA; POLYMERIZATION; DEFORMABILITY; PREVALENCE; DISORDERS; TRIAL;
D O I
10.1039/c9an02250c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nearly 7% of the world's population live with a hemoglobin variant. Hemoglobins S, C, and E are the most common and significant hemoglobin variants worldwide. Sickle cell disease, caused by hemoglobin S, is highly prevalent in sub-Saharan Africa and in tribal populations of Central India. Hemoglobin C is common in West Africa, and hemoglobin E is common in Southeast Asia. Screening for significant hemoglobin disorders is not currently feasible in many low-income countries with the high disease burden. Lack of early diagnosis leads to preventable high morbidity and mortality in children born with hemoglobin variants in low-resource settings. Here, we describe HemeChip, the first miniaturized, paperbased, microchip electrophoresis platform for identifying the most common hemoglobin variants easily and affordably at the point-of-care in low-resource settings. HemeChip test works with a drop of blood. HemeChip system guides the user step-by-step through the test procedure with animated on-screen instructions. Hemoglobin identification and quantification is automatically performed, and hemoglobin types and percentages are displayed in an easily understandable, objective way. We show the feasibility and high accuracy of HemeChip via testing 768 subjects by clinical sites in the United States, Central India, sub-Saharan Africa, and Southeast Asia. Validation studies include hemoglobin E testing in Bangkok, Thailand, and hemoglobin S testing in Chhattisgarh, India, and in Kano, Nigeria, where the sickle cell disease burden is the highest in the world. Tests were performed by local users, including healthcare workers and clinical laboratory personnel. Study design, methods, and results are presented according to the Standards for Reporting Diagnostic Accuracy (STARD). HemeChip correctly identified all subjects with hemoglobin S, C, and E variants with 100% sensitivity, and displayed an overall diagnostic accuracy of 98.4% in comparison to reference standard methods. HemeChip is a versatile, mass-producible microchip electrophoresis platform that addresses a major unmet need of decentralized hemoglobin analysis in resource-limited settings.
引用
收藏
页码:2525 / 2542
页数:18
相关论文
共 50 条
  • [21] Advances in paper-based point-of-care diagnostics
    Hu, Jie
    Wang, ShuQi
    Wang, Lin
    Li, Fei
    Pingguan-Murphy, Belinda
    Lu, Tian Jian
    Xu, Feng
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 585 - 597
  • [22] Paper-Based Systems for Point-of-Care Biosensing
    Cheung, Sherine F.
    Cheng, Samantha K. L.
    Kamei, Daniel T.
    JALA, 2015, 20 (04): : 316 - 333
  • [23] Smartphone-Enabled Paper-Based Hemoglobin Sensor for Extreme Point-of-Care Diagnostics
    Biswas, Sujay K.
    Chatterjee, Subhamoy
    Bandyopadhyay, Soumya
    Kar, Shantimoy
    Som, Nirmal K.
    Saha, Satadal
    Chakraborty, Suman
    ACS SENSORS, 2021, 6 (03) : 1077 - 1085
  • [24] Chitosan-modified nitrocellulose membrane for paper-based point-of-care testing
    Tang, Rui Hua
    Li, Min
    Liu, Li Na
    Zhang, Su Feng
    Alam, Nur
    You, Minli
    Ni, Yong Hao
    Li, Ze Dong
    CELLULOSE, 2020, 27 (07) : 3835 - 3846
  • [25] Chitosan-modified nitrocellulose membrane for paper-based point-of-care testing
    Rui Hua Tang
    Min Li
    Li Na Liu
    Su Feng Zhang
    Nur Alam
    Minli You
    Yong Hao Ni
    Ze Dong Li
    Cellulose, 2020, 27 : 3835 - 3846
  • [26] Equipment-Free Quantitative Readout in Paper-Based Point-of-Care Testing
    Li, Zedong
    You, Minli
    Bai, Yuemeng
    Gong, Yan
    Xu, Feng
    SMALL METHODS, 2020, 4 (04)
  • [27] Integrated Anemia Detection and Hemoglobin Variant Identification Using Point-of-Care Microchip Electrophoresis
    An, Ran
    Hasan, Muhammad Noman
    Man, Yuncheng
    Gurkan, Umut A.
    BLOOD, 2019, 134
  • [28] Multispectral imaging for MicroChip electrophoresis enables point-of-care newborn hemoglobin variant screening
    An, Ran
    Huang, Yuning
    Rocheleau, Anne
    Avanaki, Alireza
    Thota, Priyaleela
    Zhang, Qiaochu
    Man, Yuncheng
    Sekyonda, Zoe
    Segbefia, Catherine, I
    Dei-Adomakoh, Yvonne
    Mensah, Enoch
    Ohene-Frempong, Kwaku
    Odame, Isaac
    Owusu-Ansah, Amma
    Gurkan, Umut A.
    HELIYON, 2022, 8 (12)
  • [29] Multispectral Imaging for Microchip Electrophoresis Enables Point-of-Care Newborn Hemoglobin Variant Screening
    An, Ran
    Huang, Yuning
    Rocheleau, Anne
    Avanaki, Alireza
    Thota, Priyaleela
    Man, Yuncheng
    Sekyonda, Zoe
    Segbefia, Catherine
    Adomakoh, Yvonne
    Mensah, Enoch
    Odame, Isaac
    Gurkan, Umut A.
    BLOOD, 2021, 138
  • [30] Paper-based α-amylase detector for point-of-care diagnostics
    Dutta, Satarupa
    Mandal, Nilanjan
    Bandyopadhyay, Dipankar